40. DO NOT PUT FINGERS IN THE BLEEDER
OR CLEARANCES IN THE HOUSING.
This can result in injury, electric shock or
burns.
41. DO NOT USE ANY ADAPTER PLUGS
WITH THE COMPRESSOR
The compressor is factory-equipped with a
specific electric cord and plug for connection
to a proper electric power source. Never
modify the plug in any way. Do not use any
adapter plugs with the compressor.
42. IF OPERATING THIS COMPRESSOR IN A
DAMP LOCATION IS UNAVOIDABLE, USE
A GROUND FAULT CIRCUIT INTERRUPT-
ER (GFCI) PROTECTED SUPPLY
Use of a GFCI reduces the risk of electric
shock.
3. SPECIFICATIONS
Product No.
AKHL1260E/EX(CE)
AKHL1260E/EX(USA)
Dimensions
L
583mm / EX:583mm 23" / EX:23"
W
309mm / EX:380mm 12-1/8" / EX:15"
H
337mm / EX:479mm 13-1/4" / EX:18-7/8"
Weight
16.2kg / EX:23.3kg
35.4lbs / EX:51.1lbs
Power supply
a.c.230V±10%
50Hz±1% Ø1
a.c.115V±10%
60Hz±1% Ø1
Rated current
6A
12A
Tank capacity
4.3lx2 / EX:4.3lx5 1.14Gal.x2 / EX:1.14Gal.x5
Motor power
2HP
Protective earthing
Class1
Protective structure
IP20
Working temperature
0°C to +40°C 32°F to 104°F
Working humidity
85%RH or less. No dew condensation.
Height above sea level
UP to 1000m 3,281ft.
Storage temperature
-10°C to +50°C 14°F to 122°F
Storage humidity
85%RH or less. No dew condensation.
Pressure switch working range
OFF: 34 bar 500 psi
ON: 30 bar 435 psi
Содержание AKHL1260E Powerlite