Photocell (Thru-Beam) CLOSING Direction
Single Gate Operator

Transmitter

(TX)

Receiver

(RX)

Single

Operator

CLOSING direction Thru-Beam

Gate Closed

emx irb-mon

IMPORTANT: 

Photocells MUST be powered 

by Matrix III or they will 

NOT

 be 

MONITORED

.

12VDC OUT

Polarity does 

NOT

 matter

NC

NO

NC

COM

COM NO

RX

POWER

INPUT

JUMPER

EARTH

GND

SENSITIVITY

TX

POWER INPUT

TRANSMITTER

BOARD (TX)

ON

DIP

1
2
3
4

RECEIVER

BOARD (RX)

Sensitivity Adjustment:

If the photocell does not 
respond to an obstruction, 
lower the sensitivity by 
turning adjustment 
counter-clockwise.

Transmitter (TX)

Receiver (RX)

PHOTO CLS NC - 

Normally Closed

GND - 

Common

NO

Com

NC

Green
LED

To 

PHOTO CLS NC

and 

12VDC OUT

 Input 

To Matrix III

12VDC OUT

 Input 

TX

RX

Jumper

Green
LED

NOTE: To meet the UL 325 2018 standard, Type B1 
Non-Contact sensor entrapment protection device 
MUST be MONITORED by the gate operator.

Installation Steps:

1.

Set DIP-switches on receiver.

2.

Install jumper on receiver.

3.

Wire Matrix III 

12VDC OUT

power to receiver.

4.

Wire 

PHOTO CLS NC

to receiver photocell 

NC.

Wire Matrix III 

GND

 to

receiver 

photocell 

COM.

5.

Wire 

12V

 Matrix III

power to transmitter.

6.

Align photocells.

7.

Adjust sensitivity on receiver.

Jumper 

MUST

 be on Com-NC.

DIP-switches:

1, 2, 3 are 

OFF.

Switch 4 is 

ON

If trouble occurs, try 
turning switch 4 OFF.

NOTE:

 Power must be 

cycled when switches 
are changed.

IMPORTANT:

 

Photocells 

MUST 

be 

in alignment or fault will occur. 
Green LED will remain 

ON

 receiver 

when in proper alignment.

OPEN ONLY 

NC

OPEN ONLY 

10K

PHOTO CLS 

NC

OPEN/CLS 

NC

GND

12VDC OUT

GND

CLS ONLY 

10K

OPEN/CLS 

10K

12VDC OUT

UL SENSOR N.C.

UL SENSOR 10K

P

NSOR N.C

P

NSOR N.C

P

SOR N.

P

SOR N

SOR N

SOR N

OR N

OR N

OR 

UL SEN

N

UL SEN

UL SEN

UL SEN

UL SE

UL SE

UL SE

L SE

L S

24

UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install 

Version 7a

Содержание 1500 PRO

Страница 1: ...om 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV MAX F18 PRO UL CLASS III IV ONLY CERTIFIED TO CAN CSA...

Страница 2: ...t lors de l ouverture et de la fermeture la barri re doit tre install e dans un endroit o la barri re et les structures avoisinantes sont suffisamment loign es l une de l autre Les barriers battantes...

Страница 3: ...1 Au moins un capteur de contact doit tre situ o il existe un risque de coincement ou d obstruction comme sur le bord d ouverture sur le bord de fermeture et sur les poteaux mont s sur l int rieur ou...

Страница 4: ...etest the gate operator properly can increase the risk of injury or death 4 V rifiez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inverser lorsque la barri re en...

Страница 5: ...25 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivalent B2 Provision for connection of a contact sen...

Страница 6: ...stalled where entrapment or pinch point exist A minimum of TWO entrapment protection sensors MUST be installed ONE in EACH direction of gate travel or operator will NOT function Physical Stops Install...

Страница 7: ...29 UL 325 Class of Operation MAX 1500 PRO 2200 PRO Class I II III IV MAX F18 PRO Class III IV ONLY Gate Type Vehicular Slide Gate Max Gate Length 50 ft Max Gate Weight MAX 1500 PRO 1500 lbs Level Gate...

Страница 8: ...round to avoid flooding Concrete Depth Note The heavier the gate the deeper the concrete pad should be At least two feet recommended for heavier gate Secure gate operator to concrete pad with four 4 1...

Страница 9: ...or is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet of t...

Страница 10: ...75 7 5 7 5 6 75 Cover 1 5 4 5 6 5 8 625 12 75 Conduit Area Outside Property Inside Property Input Power Physical Stop Conduit Run Operator MUST be level Concrete Pad Check local building codes in your...

Страница 11: ...heel Approx 1 5 Pulley Wheel Safety Cover Gate YES YES Modify Cover for Rear Mounting Position 16 5 Cut out cover between new hole and existing chain exit slot Make sure cuts are plumb with existing c...

Страница 12: ...Amp Select Input Voltage 115VAC or 230VAC 1 1 5 V MAX Toroid Box ac input power 2 GFCI Outlet NOT provided DANGER HIGH VOLTAGE Additional Gang Box Choose either 115V or 230V setting on input AC power...

Страница 13: ...r or F Bat ter y Mo dul e Ground within 3 ft of operator Any of the THREE Chassis Grounds can be used They are located next to the gear reducer DO NOT remove any existing green ground wires 1 2 3 Grou...

Страница 14: ...C UL SENSOR 10K entrapment protection wiring 5 Entrapment Protection Device Options and Locations Beam 5 or LESS from CLOSED gate Conduit Entrapment Area CLOSING Direction Photocell Wall Gate Closed...

Страница 15: ...Mini Edge Contact Edge Sensor ASO Edge Thin Edge MAX Edge 1 Contact Edge Sensor Test Connected Sensors Test ALL connected entrapment protection sensors using learn mode 1 Press and HOLD the STOP butt...

Страница 16: ...PEN GATE SPEED MAG LOCK UL ENTRAP PRIMARY SECONDARY LINK STOP CLOSE MOTOR INPUTS CLOSE TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN O...

Страница 17: ...ter clockwise to reduce gate sensitivity while testing ERD until desired results is attained LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or 4 t...

Страница 18: ...Detectors to HIGH sensitivity to avoid false trigger NOTE DO NOT select the PULSED output option for Loop Detectors EDI Loop Detector EDI Loop Detector Low Current Draw ON 1 2 3 4 5 6 7 8 5 Op tim um...

Страница 19: ...en wired to indicated inputs MUST be LEARNED BEFORE they will be MONITORED 2 Press and HOLD the STOP button then the OPEN button together until beeping is heard learn mode begins DO NOT press the OPEN...

Страница 20: ...EN OPEN 1 TIME BATTERY VOLTAGE E F 1 2 RESET MANUAL RELEASE ID PLUG LINK OK MODULE PORT MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT...

Страница 21: ...servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while servicing the operator This can prevent...

Страница 22: ...3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON OFF 2 5 sec 1 5 sec OPERATOR MATRIX III OFF 3 1 14 16 MIN 16 MIN 12 9 7 3 1 14 12 9 7 UL SENSOR N C UL SENSOR 10K POWER MODE A LOOP LOOP LOOP GATE OPEN...

Страница 23: ...SOR 10K POWER MODE A MODE B EXIT LOOP LOOP LOOP CENTER SAFETY GATE OPEN COM GATE CLOSED MIN MATRIX III SWING SLIDE Gate Tamper Relay The GATE TAMPER is factory set to OFF Unarmed See previous page for...

Страница 24: ...IGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD CARD GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM STOP OPEN CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO CO...

Страница 25: ...GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO COM NC ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY LEFT ON OFF B...

Страница 26: ...RI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated Fri 07 11 2014 10 57 21 INFO Radio Input Ac vated Fri 07 11 2014 10 56 46 WARNING PRI_MC Tamper Reported Fri 07 11 2014 10...

Страница 27: ...TERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to OPEN...

Страница 28: ...S ONLY 10K LED is ON PHOTO CLS LED is flashing CLS ONLY 10K LED is flashing OPEN ONLY LED is ON OPEN ONLY LED is FLASHING MAX SENSE LED is ON MANUAL RELEASE RESET LED is ON but manual release is not w...

Страница 29: ...flashing Loop fault condition check if SAFETY loop wires are connected into to loop input connector properly Check if SAFETY loops are wired in series Check if loop detector is inserted properly in L...

Страница 30: ...a...

Страница 31: ...protection device MUST be MONITORED by the gate operator Installation Steps 1 Set DIP switches on receiver 2 Install jumper on receiver 3 Wire Matrix III 12VDC OUT power to receiver 4 Wire PHOTO CLS...

Страница 32: ...nd to an obstruction lower the sensitivity by turning adjustment counter clockwise Transmitter TX Secondary Matrix III Receiver RX Normally Closed PHOTO CLS NC Common GND Green LED Green LED NOComNC J...

Страница 33: ......

Страница 34: ...NC Power NC Jog Left Jog Right External Alarm Reset Button Dry Contact Security Device PRESS to RESET ID Plug Specific for operator type REQUIRED Maglock Solenoid Lock Motion Sensor External Jog Left...

Страница 35: ...hain 7 JOG gate closed slightly and install magnet 8 Gate positions can now be learned see Plug OPEN JOG LEFT RIGHT optional magnet limit sensors CLOSING CLOSING OPENING RD OTOR VER OAD ERD MOTOR OVER...

Страница 36: ...GNAL STRIKE STOP OPEN ID PLUG ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY SECONDARY ON QUICK CLOSE OPEN LEFT O R GATE OFF 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON FAULT...

Страница 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 40: ...708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA SAFETY SENSORS REQUIRED MATRIX III CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV M...

Отзывы: