matrix III led continued

Matrix III LED

Problem Condition

Solution(s) for

Problem Condition

Normal

LED

“ID PLUG” LED is FLASHING and board beeping

“SOLAR MODE” LED is ON

“OPEN/CLS” LED is ON

“OPEN/CLS” LED is FLASHING

“MOTOR OVERLOAD” LED is ON 

“EXIT” LOOP LED is FLASHING or
constantly ON

“SAFETY” LOOP LED is FLASHING or
constantly ON

“GATE DISABLE” LED is ON

“MAG LOCK” LED is FLASHING

“GATE TAMPER” LED is FLASHING

“12VDC” LED is OFF.  “24VDC” LED is OFF

“SLIDER LIMIT” LED is ON

“ON/OFF BATTERY” LED is OFF

“QUICK CLOSE” LED is ON

“GATE SPEED” LEDs are ON but gate moves 
slowly.

 Insert ID PLUG module that is tethered to chassis into “ID PLUG” connector.

 Operator is being powered by solar panel ONLY.

 Sensor on OPEN/CLS input (photocell or edge) may have detected an obstruction while opening or 

closing gate.

 Photocell on OPEN/CLS input is misaligned with reflector.

 Sensor on OPEN/CLS input (photocell or edge) may not be wired properly, (see     ).

 Sensor is NOT a N.C. monitored sensor that is UL325 2018 compliant.

 Sensor on OPEN/CLS is damaged or malfunctioning.

 Sensor might need to be re-learned.

 Check if gate is binding against catch post or bracket in opened or closed position.

 Check if gate moves manually with low resistance throughout its full range of motion.

 Check if chain is installed inline with idle wheels in both OPEN and CLOSED positions.

 Loop fault condition: Check if EXIT loop wires are connected into to loop input connector properly.

 Check if loop detector is inserted properly in Loop Rack slot.

 Set unique loop detector frequency for each loop detector used.

 Loop Detector might be defective. Replace defective loop detector.

NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).

 Loop fault condition: check if SAFETY loop wires are connected into to loop input connector properly.

 Check if SAFETY loops are wired in series.

 Check if loop detector is inserted properly in Loop Rack slot.

 Set unique loop detector frequency for each loop detector used.

 Loop Detector might be defective. Replace defective loop detector.

NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).

 Check if “Gate Shut-off” switch is ON, Turn it OFF.  If it is OFF, cycle the switch (ON then OFF). 

• 

Check if the chain is dropped. If so, gate is disabled for safety. Re-install chain and cycle the "Gate 
Shut-off" switch (ON then OFF) to enable operator. 

 Check if an external device is triggering GATE DISABLE input. Disconnect devices individually to 

determine possible false triggering of GATE DISABLE.

 Maglock power is lost. Check if maglock power transformer is wired properly or needs to be replaced.

 Switch is set to delay but no maglock is connected. Set switch to OFF

 Gate was manually moved off of its CLOSED position causing Tamper Relay to trigger for few seconds.

 Check for a short in wiring to connected device. DO NOT power external keypads or telephone entry to 

this port (only use for radio receiver / photocell).

 Only ON if factory installed plug is plugged in. Re-install plug into SWING LIMIT connection for swing 

gate operator.

 Batteries are turned OFF. Turn toroid box AC POWER switch ON and batteries automatically turn ON.

 Quick Close feature is turned ON. If this feature is not desired, turn quick close OFF.

• 

Check if OPEN and CLOSE Limits have been learned. Refer to “Learn Gate Positions” (see     ).

 ONLY Maximum settings will turn LEDs ON. All other settings, LEDs remain OFF.

OFF

12

OFF

13

OFF

31

OFF

8

OFF

15

OFF

17

OFF

35

OFF

28

OFF

34

ON

18 or 19

OFF

21

ON

22

OFF

23

ON

42

5

7

22

UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install 

Version 7a

Содержание 1500 PRO

Страница 1: ...om 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV MAX F18 PRO UL CLASS III IV ONLY CERTIFIED TO CAN CSA...

Страница 2: ...t lors de l ouverture et de la fermeture la barri re doit tre install e dans un endroit o la barri re et les structures avoisinantes sont suffisamment loign es l une de l autre Les barriers battantes...

Страница 3: ...1 Au moins un capteur de contact doit tre situ o il existe un risque de coincement ou d obstruction comme sur le bord d ouverture sur le bord de fermeture et sur les poteaux mont s sur l int rieur ou...

Страница 4: ...etest the gate operator properly can increase the risk of injury or death 4 V rifiez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inverser lorsque la barri re en...

Страница 5: ...25 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivalent B2 Provision for connection of a contact sen...

Страница 6: ...stalled where entrapment or pinch point exist A minimum of TWO entrapment protection sensors MUST be installed ONE in EACH direction of gate travel or operator will NOT function Physical Stops Install...

Страница 7: ...29 UL 325 Class of Operation MAX 1500 PRO 2200 PRO Class I II III IV MAX F18 PRO Class III IV ONLY Gate Type Vehicular Slide Gate Max Gate Length 50 ft Max Gate Weight MAX 1500 PRO 1500 lbs Level Gate...

Страница 8: ...round to avoid flooding Concrete Depth Note The heavier the gate the deeper the concrete pad should be At least two feet recommended for heavier gate Secure gate operator to concrete pad with four 4 1...

Страница 9: ...or is NOT parallel to gate Chain is NOT parallel to gate DO NOT mount chain bracket too high on gate NO NO YES YES YES YES Drive Gear NOTE The chain should sag no more than one 1 inch per 10 feet of t...

Страница 10: ...75 7 5 7 5 6 75 Cover 1 5 4 5 6 5 8 625 12 75 Conduit Area Outside Property Inside Property Input Power Physical Stop Conduit Run Operator MUST be level Concrete Pad Check local building codes in your...

Страница 11: ...heel Approx 1 5 Pulley Wheel Safety Cover Gate YES YES Modify Cover for Rear Mounting Position 16 5 Cut out cover between new hole and existing chain exit slot Make sure cuts are plumb with existing c...

Страница 12: ...Amp Select Input Voltage 115VAC or 230VAC 1 1 5 V MAX Toroid Box ac input power 2 GFCI Outlet NOT provided DANGER HIGH VOLTAGE Additional Gang Box Choose either 115V or 230V setting on input AC power...

Страница 13: ...r or F Bat ter y Mo dul e Ground within 3 ft of operator Any of the THREE Chassis Grounds can be used They are located next to the gear reducer DO NOT remove any existing green ground wires 1 2 3 Grou...

Страница 14: ...C UL SENSOR 10K entrapment protection wiring 5 Entrapment Protection Device Options and Locations Beam 5 or LESS from CLOSED gate Conduit Entrapment Area CLOSING Direction Photocell Wall Gate Closed...

Страница 15: ...Mini Edge Contact Edge Sensor ASO Edge Thin Edge MAX Edge 1 Contact Edge Sensor Test Connected Sensors Test ALL connected entrapment protection sensors using learn mode 1 Press and HOLD the STOP butt...

Страница 16: ...PEN GATE SPEED MAG LOCK UL ENTRAP PRIMARY SECONDARY LINK STOP CLOSE MOTOR INPUTS CLOSE TIMER MAGLOCK DELAY JOG BATTERY TEST INPUT ERROR BATTERY BATTERY IN USE REPLACE BATTERY LEAVE CLOSED LEAVE OPEN O...

Страница 17: ...ter clockwise to reduce gate sensitivity while testing ERD until desired results is attained LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or 4 t...

Страница 18: ...Detectors to HIGH sensitivity to avoid false trigger NOTE DO NOT select the PULSED output option for Loop Detectors EDI Loop Detector EDI Loop Detector Low Current Draw ON 1 2 3 4 5 6 7 8 5 Op tim um...

Страница 19: ...en wired to indicated inputs MUST be LEARNED BEFORE they will be MONITORED 2 Press and HOLD the STOP button then the OPEN button together until beeping is heard learn mode begins DO NOT press the OPEN...

Страница 20: ...EN OPEN 1 TIME BATTERY VOLTAGE E F 1 2 RESET MANUAL RELEASE ID PLUG LINK OK MODULE PORT MOTOR POSITION INPUTS SLIDER LIMIT SWING LIMIT OPEN ONLY NC OPEN ONLY 10K PHOTO CLS NC OPEN CLS NC GND 12VDC OUT...

Страница 21: ...servicing the operator to prevent the switch from accidentally being turned ON during normal operation Plug the wire back in and turn ON the switch only while servicing the operator This can prevent...

Страница 22: ...3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON OFF 2 5 sec 1 5 sec OPERATOR MATRIX III OFF 3 1 14 16 MIN 16 MIN 12 9 7 3 1 14 12 9 7 UL SENSOR N C UL SENSOR 10K POWER MODE A LOOP LOOP LOOP GATE OPEN...

Страница 23: ...SOR 10K POWER MODE A MODE B EXIT LOOP LOOP LOOP CENTER SAFETY GATE OPEN COM GATE CLOSED MIN MATRIX III SWING SLIDE Gate Tamper Relay The GATE TAMPER is factory set to OFF Unarmed See previous page for...

Страница 24: ...IGHT JOG LEFT TAMPER IN TAMPER NO GATE DISABLE MANUAL RELEASE KEYPAD CARD GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM STOP OPEN CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO CO...

Страница 25: ...GND GND GND MAX OPEN FIRE DEPT RADIO GND RADIO SIGNAL STRIKE CLOSE COM COM CLS ONLY 10K OPEN CLS 10K 12VDC OUT NO COM NC ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY LEFT ON OFF B...

Страница 26: ...RI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated Fri 07 11 2014 10 57 21 INFO Radio Input Ac vated Fri 07 11 2014 10 56 46 WARNING PRI_MC Tamper Reported Fri 07 11 2014 10...

Страница 27: ...TERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to Leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to OPEN...

Страница 28: ...S ONLY 10K LED is ON PHOTO CLS LED is flashing CLS ONLY 10K LED is flashing OPEN ONLY LED is ON OPEN ONLY LED is FLASHING MAX SENSE LED is ON MANUAL RELEASE RESET LED is ON but manual release is not w...

Страница 29: ...flashing Loop fault condition check if SAFETY loop wires are connected into to loop input connector properly Check if SAFETY loops are wired in series Check if loop detector is inserted properly in L...

Страница 30: ...a...

Страница 31: ...protection device MUST be MONITORED by the gate operator Installation Steps 1 Set DIP switches on receiver 2 Install jumper on receiver 3 Wire Matrix III 12VDC OUT power to receiver 4 Wire PHOTO CLS...

Страница 32: ...nd to an obstruction lower the sensitivity by turning adjustment counter clockwise Transmitter TX Secondary Matrix III Receiver RX Normally Closed PHOTO CLS NC Common GND Green LED Green LED NOComNC J...

Страница 33: ......

Страница 34: ...NC Power NC Jog Left Jog Right External Alarm Reset Button Dry Contact Security Device PRESS to RESET ID Plug Specific for operator type REQUIRED Maglock Solenoid Lock Motion Sensor External Jog Left...

Страница 35: ...hain 7 JOG gate closed slightly and install magnet 8 Gate positions can now be learned see Plug OPEN JOG LEFT RIGHT optional magnet limit sensors CLOSING CLOSING OPENING RD OTOR VER OAD ERD MOTOR OVER...

Страница 36: ...GNAL STRIKE STOP OPEN ID PLUG ERROR 24VDC OUTPUT 12VDC OUTPUT GND GND GND LOOP PWR OFF PRIMARY SECONDARY ON QUICK CLOSE OPEN LEFT O R GATE OFF 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 MIN MIN MAX MAX ON FAULT...

Страница 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...

Страница 40: ...708 Tel 949 699 0220 4009963 Residential Commercial Brushless DC Slide Gate Operators Made in USA SAFETY SENSORS REQUIRED MATRIX III CONFORMS TO UL STD 325 MAX 1500 PRO 2200 PRO UL CLASS I II III IV M...

Отзывы: