NC
NC
NC
Power
Additional Unlearned Input
Factory Learned Input
Factory Learned Input
Unlearned Input
Unlearned Input
Additional Unlearned
Input
Power
NC
Normally Closed Photocells
Closing Direction -
Factory Learned Input,
does
NOT
need to be learned.
Opening Direction -
Factory Learned Input,
does
NOT
need to be learned.
10K Sensing Edges
Bi-Parting Gates NOTE:
Connect
sensors to
EITHER
operator
when using dual gates.
Learned Inputs NOTE:
Connect sensors will function when they are
NOT
learned but they will
NOT
be
MONITORED
and
NOT
recommended.
See pages 23-26
for specific wiring.
Opening Direction
must be learned to be
monitored, see page 12.
Closing Direction
must be learned to be
monitored, see page 12.
MAG
LOCK
UL
ENTRAP
MAGLOCK
DELAY
GND
OPEN ONLY
NC
OPEN ONLY
10K
PHOTO CLS
NC
OPEN/CLS
NC
GND
12VDC OUT
GND
GND
GND
JOG LEFT
JOG RIGHT
TAMPER IN
TAMPER NO
COM
CLS ONLY
10K
OPEN/CLS
10K
12VDC OUT
NO
COM
NC
LEFT
RIGHT
OFF
2.5 sec
1.5 sec
UL SENSOR N.C.
UL SENSOR 10K
entrapment protection wiring
5
Entrapment Protection Device Options and Locations:
Beam: 5” or LESS
from CLOSED gate.
Conduit
Entrapment Area
CLOSING Direction Photocell
Wall
Gate Closed
Outside Property
Inside Property
Continued on next page.
IMPORTANT:
Photocells
MUST
be in alignment or fault will occur.
Gate
Wa
ll
Outside
Property
Inside
Property
Entrapment Area
Photo Beam
OPENING Direction Photocell
Beam: 5” or LESS from OPEN gate.
Gate Closed
Wall
Conduit
Illustrations not to scale
Outside Property
Inside Property
IMPORTANT:
Photocells
MUST
be in alignment or fault will occur.
Beam Height:
21” for most installations but No
higher than 27.5” above ground.
UL 325 2018 Standard
IMPORTANT:
N.C. type
sensing devices
MUST
be
powered by Matrix III
12VDC OUT
input or they
will
NOT
be
MONITORED
.
A minimum of
TWO
entrapment protection sensors
MUST
be installed,
ONE
in
EACH
direction of gate
travel or operator will NOT function.
They MUST be MONITORED and NORMALLY CLOSED
(N.C.)/10K. All entrapment zones should be protected
by MONITORED sensors.
12VDC OUT monitored
7
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install
Version 7a
Содержание 1500 PRO
Страница 30: ...a...
Страница 33: ......
Страница 37: ...30 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Страница 38: ...31 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...
Страница 39: ...32 UL 325 2018 Standard MAX 1500 PRO 2200 PRO F18 PRO Matrix III Install Version 7a...