Matsusada DOP Series Скачать руководство пользователя страница 7

 

vi

 

 

 
 

 

 

 

1. WARRANTY POLICY 

Matsusada Precision Inc. ("Matsusada") warrants that the products supplied by it will be free from 
defects in materials and workmanship for a period of twelve (12) months from the date of original 
shipment to buyer. This warranty shall not apply to any product which has been repaired, modified 
or  worked  on  by  persons  unauthorized  by  Matsusada,  used  other  than  in  accordance  with  the 
instruction  manuals,  used  in  inappropriate  environment  (with  corrosive  gas,  high  humidity,  etc)  or 
damaged  by  any  event  beyond  Matsusada's  control  such  as  force  majeure.  Matsusada  shall  in  no 
way be liable for any incidental, special or consequential damages relating to this warranty.   
Matsusada's sole liabilities and the buyer's sole remedies shall be limited, at Matsusada's discretion, 
to a repair or replacement of the products.   
The  foregoing  warranty  is  in  lieu  of  all  other  warranties,  express  or  implied,  including  those  of 
merchantability or fitness for a particular purpose. 
As  the  products  are  not  designed  and  manufactured  for  applications  which  require  extraordinary 
reliability  or  safety,  or  affecting  people's  life  (nuclear  energy,  aerospace,  socially  fundamental 
facility,  medical  equipment,  etc),  this  warranty  shall  not  be  applied  for  such  applications.  The 
specific design and manufacturing might be required for such applications.   
No  modification  or  supplement  of  this  warranty  shall  be  binding  unless  in  writing  and  signed  by  a 
duly authorized officer of Matsusada. 

 

2. INSTRUCTION MANUAL AND TEST DATA 

Each rack mount and bench top power supply have 1 instruction manual. Extra instruction manuals 
available with charge. 

Schematics of products shall not be submitted to users. Test result or test data for the products 
shall be available upon request with charge.   

 

WARRANTY 

Содержание DOP Series

Страница 1: ...Rev 0 7 B N 103 9 053 103 9 053 MODEL DOP SERIES Instruction Manual F RA 001 3R1 ...

Страница 2: ...rcuit are still charged and dangerous even after the power has been cut off Discharge all remaining high voltage by grounding them 5 DISCONNECT THE INPUT LINES AC LINES In case you need to touch the inside of the power supply following instruction manual cut off the power and disconnect the input lines AC lines and ground all the capacitors and high voltage section Don t remove the case or touch t...

Страница 3: ... immediately after it is stopped Otherwise it may cause electric shock or injury Do not install the unit in a place subject to steam or water vapor Otherwise it may cause poor insulation and lead to fire or electric shock Do not install the unit in a place subject to dew condensation Otherwise it may cause electric shock Do not modify or damage the cables Otherwise it may cause electric shock Be s...

Страница 4: ...the unit with chemicals such as thinner or wet cloth It may allow water inside leading to electric shock electrical leak or burning Do not cover the vent holes of the unit Vent holes are provided to prevent elevation of temperature inside Covering them not only hampers the unit from achieving its performance but also causes deterioration of parts which may generate smoke or set fire Do not install...

Страница 5: ...tim is not breathing properly give artificial respiration see next page TREATMENT 1 Start artificial respiration at scene of accident Only in case victim s or operator s life is endangered remove victim to safe location nearby 2 After starting artificial respiration continue without loss of rhythm until victim start breathing without help or being passed to medical aid 3 When operator change while...

Страница 6: ...Take a deep breath seal victim s open mouth and exhale firmly into victim s mouth until chest is seen to lift Make sure to open mouth widely to avoid air leakage 7 REMOVE MOUTH AND CHECK Check the sound of breathing out air and see normal breathing when releasing mouth If no sound repeat from OPEN AIR PASSAGE Continue at a rate of 12 to 20 times per minute Quantity of air have to be increased grad...

Страница 7: ...a repair or replacement of the products The foregoing warranty is in lieu of all other warranties express or implied including those of merchantability or fitness for a particular purpose As the products are not designed and manufactured for applications which require extraordinary reliability or safety or affecting people s life nuclear energy aerospace socially fundamental facility medical equip...

Страница 8: ...ction for handling 3 1 Overview 3 2 Connection to the load 3 3 Connection of AC input cable 3 4 Operations 3 5 Select CV CC setting 3 6 Using bias 3 7 Remote sensing 3 8 Other features a Over Voltage Protection O V P b Over Current Protection O C P c Power outage protection 3 9 Over Current Protection 3 10 Output Range 3 11 Remote ON OFF switch 3 12 Inter lock 4 Optional Features 4 1 Cancel power ...

Страница 9: ...hortly 1 2 Unpacking the bi polar amplifier When unpacked the unit you will please check the following accessories are enclosed with the power supply main body Accessories AC input cable 1 pc Instruction manual Master slave connection cable with LMs option 1 3 Environmental requirements Place and use the power supply horizontally Never place any object on the power supply There are air suction and...

Страница 10: ...REATION 1 Laying an insulation plate which can withstand the voltage to be used on the floor on which an operator stands carry out the operation If done so it will be comparatively safe 2 When operating a power supply and load do so with right hand with left hand put in the pocket taking care not to touch other objects 3 After turning off the voltage even if a long time has lapsed after turning of...

Страница 11: ...eries circuit between output terminals to prevent resonance Response speed When accurate output waveforms are required select a bi polar amplifier with a frequency bandwidth adequately higher than the used frequency In case of using in sine waves 3 to 5 times quick frequency bandwidth is required and around 10 times quick one is required in case of using in square waves in general Inadequate bandw...

Страница 12: ...frequency bandwidth Fc Hz is generally acquired by trap proximately 0 35 fc Falling time tf is the same as tr 1 7 Connection Precaution Since minus on secondary side and common are internally connected please use minus common Plus common cannot be used Power supplies cannot be connected in parallel except for units with LMs option 1 Introduction Vcon in 90 100 tf tr 10 0 0 HVout ...

Страница 13: ...ge meter Current meter Output voltage limiter option Output current limiter option CV CC select switch Vcon in terminal 2 2 Rear panel 350W Io 30A type Output terminal Voltage monitor terminal Current monitor terminal AC input terminal Connector for Master slave option Inter lock Remote switch ON OFF 2 Exterior view diagram 2 Exterior view diagram REMOTE ON OFF INTERLOCK INPUT AC100 120V ...

Страница 14: ...urrent meter Output voltage limiter option Output current limiter option CV CC select switch Vcon in terminal 2 4 Rear panel 600 720W Vo 120V and Io 60A type Output terminal Voltage monitor terminal Current monitor terminal AC input terminal Connector for Master slave option Inter lock Remote switch ON OFF 2 Exterior view diagram INPUT AC200 240V INTERLOCK REMOTE ON OFF ...

Страница 15: ...LED OUTPUT ON OFF switch Voltage meter Current meter Output current limiter option Output voltage limiter option CV CC select switch Vcon in terminal 2 Exterior view diagram INPUT AC200 240V INTERLOCK REMOTE ON OFF Output terminal Current monitor terminal Connector for Master slave option Remote switch ON OFF Voltage monitor terminal AC input terminal 300W type is 100 120VAC Inter lock ...

Страница 16: ...120V Vo type Output terminal Voltage monitor terminal Current monitor terminal Inter lock Remote switch ON OFF Connector for Master slave option AC input terminal 2 Exterior view diagram INPUT AC200 240V INTERLOCK REMOTE ON OFF ...

Страница 17: ... Io 80A type Output terminal Voltage monitor terminal Current monitor terminal Inter lock Remote switch ON OFF Connector for Master slave option AC input terminal 2 Exterior view diagram INPUT AC200 240V INTERLOCK REMOTE ON OFF ...

Страница 18: ... Io type Output terminal Voltage monitor terminal Current monitor terminal Inter lock Remote switch ON OFF Connector for Master slave option AC input terminal 2 Exterior view diagram INPUT AC200 240V INTERLOCK REMOTE ON OFF ...

Страница 19: ... determine appropriate cable AWG mm2 Peak current A AWG mm2 Peak current A 18 16 14 12 10 8 6 1 1 1 3 2 1 3 3 5 3 8 4 13 2 7 11 18 23 39 67 4 2 1 1 0 2 0 3 0 21 33 42 53 67 85 106 170 209 270 330 350 3 3 Connection of AC input cable Attach crimping terminal to the AC input cable and connect to the distribution box of commercial power supply Power supply is AC100 120V or AC 200 240V 50 60Hz single ...

Страница 20: ...e 5 Voltage monitor Output 0 to 10V against rated output voltage Output impedance is 1kΩ 6 Current monitor Output 0 to 10V against rated output current Output impedance is 1kΩ 3 5 Select CV CC setting By inputting voltage into Vcon in output voltage can be controlled on CV mode and output current can be controlled on CC mode 3 6 Using bias Switching the bias voltage ON OFF switch to the ON positio...

Страница 21: ...er point The loss of the lead is adjusted by 0 5 V maximum Use twisted or shielded wire as the lead for sensing The sense lines are provided at the sense connector on the rear panel Make connections as described below 1 Turn the power supply OFF wait for five minutes and remove the jumpers between S and OUTPUT terminal and S and OUTPUT terminal 2 Connect the Sense and Sense as shown below Connect ...

Страница 22: ... power outage Voltage is not output after recovery from power outage Output ON OFF switch needs to be turned off and on to reset 3 9 Over Current Protection There are two circuits installed in this power supply a circuit is to limit pulse current and another is to limit normal current 3 8 b limits normal current within 1msec Another circuit is to limit pulse current at 2 times of the rated in case...

Страница 23: ...ed in DC mode or in low frequency operated please derate the output as per the following diagram Please avoid continuous use in high frequency It increases internal loss and leads to being in failure Rated output voltage Rated output current AC Operating frequency 50Hz and over duty 50 and DC bias DC Operation range 3 Instruction for handling ...

Страница 24: ...function use them according to the following rule DEFINITION OF OPEN COLLECTOR OUTPUT SWITCH OPEN COLLECTOR ON Short VCE 0 4V or less 10mA OFF Open VCE 2V or more Open 5V 3 Instruction for handling Short Open Output ON Output OFF REMOTE SWITCH ACTION Note 1 Short In place of switch an open collector will suffice for it E C 5V If connect an attached short hardware Remote ON OFF function will not wo...

Страница 25: ...condition CONNECTION DIAGRAM Inter lock action by open collector When inter lock action is not used Short Open Output ON Output OFF INTER LOCK ACTION Note 1 Short In place of switch an open collector will suffice for it E C If connect an attached short hardware Inter lock function will not work Terminal for Inter lock Inter lock Action with switch switch 3 Instruction for handling ...

Страница 26: ... 1set see 5 LMs option Instruction Manual for use method 4 4 Floating ground LF Power supply can be floated up to 200Vdc between chassis and output terminal 4 5 Output voltage limit LVc Variable from 0 to approx 110 with Output voltage limiter in front panel Set the following procedure 1 Turn off the power wait one minute and open the load 2 Turn off the bias switch turn off the output switch and ...

Страница 27: ...tput current 2 Turn off the bias switch set the bias setting dial to 5 0 turn off the output switch and set to the CV mode 3 Input the power turn on the output switch and turn the bias setting dial clockwise little by little until the current limiter is activated Factory about 110 of the rated output current 4 Set to the desired value by turning the limiter Cautions for use of LMs option To make t...

Страница 28: ...unit is connected LMs cable it will be parallel operation with master unit Then control from outside will become invalid When slave unit is not connected LMs cable it will be usual movement by an element 5 2 Connection of master unit and slave unit Prepare the attached Master slave connection cable It is written as Master Slave1 Slave2 on the D sub connector of cable so please be careful to connec...

Страница 29: ...on consideration Value of Voltage meter and Voltage monitor are correct which master units are displayed Value of Current meter and Current monitor are the sum of value master units and slave unit are displayed Select CV CC mode from master unit Connect each output terminal of master unit and slave unit directly to the load Do not connect to the load via other unit Control remote ON OFF switch or ...

Страница 30: ......