21
5-3 How to use
① Make sure input cable and Master-slave cable are connected.
② When LVc or LCc option is attached, be sure to use after OVP and OCP volume of slave set to
counterclockwise maximum.
③ Turn on POWER switch of master unit first and then turn on slave unit’s switch.
④ Turn on OUTPUT switch of slave unit first and then turn on master unit’s switch.
⑤ Input control voltage into Vcon-in of master unit. Nothing will happen even if you
input control voltage into Vcon-in of slave unit.
⑥ Setting of bias is to be done by master unit only. Slave unit cannot set it.
5-4 Application consideration
・
Value of Voltage meter and Voltage monitor are correct which master units are displayed.
・
Value of Current meter and Current monitor are the sum of value master units and slave unit are
displayed.
・
Select CV/CC mode from master unit.
・
Connect each output terminal of master unit and slave unit directly to the load. Do not connect to
the load via other unit.
・
Control remote ON/OFF switch or door switch only master unit.
・
Don
’
t make to be parallel operating without connecting master unit and slave unit.
・
Even if product is the same model, it is not possible to use by different combination, because each
combination of master and slave is for exclusive use.
5 LMs option
Instruction Manual
Master
Slave 1
Slave 2
Load
Master
Slave 1
Slave 2
○ O.K.
× N.G.
Output terminal
+
+
+
-
-
-
+
+
+
-
-
-
Load