2
1-4 Points to be careful about in handling and care
WHEN TOUCHING LOAD AFTER TURNING OFF THE OUTPUT
1.
Make the setting of an output voltage to zero (0). Turn off the OUTPUT ON/OFF
switch.
2.
Check and confirm that the voltage is zero at an output voltmeter of this unit.
3.
Turn off the POWER ON/OFF switch.
4.
Earthling an output for more than 10 seconds, check and confirm that the voltage is
zero with another high voltage meter. It is especially dangerous that the load is
capacitive or a long cable is used.
5.
Make it a rule to touch load with right hand.
FOR SAFER OPEREATION
1. Laying an insulation plate which can withstand the voltage to be used on the floor on
which an operator stands, carry out the operation. If done so, it will be comparatively
safe.
2. When operating a power supply and load, do so with right hand with left hand put in the
pocket, taking care not to touch other objects.
3.
After turning off the voltage (even if a long time has lapsed after turning off), if you
touch load, be sure to earth the output longer than 10 seconds.
1-5 What to do before calling service
In case no output
1.
Check whether or not a specified voltage has been inputted.
100-120VAC 50/60Hz single phase of input voltage.
(For output power of 600W or higher, 200-240VAC 50/60Hz single phase)
2. Check whether or not a connection is correct.