106 Appendix B: Technical information
The pinout for internal 10-pin auxiliary I/O connector is as follows. Refer to the
description of external auxiliary I/O connector 1 to establish if an auxiliary signal
is specific to an independent acquisition path and the type of signals that can be
routed onto it.
28
NC
Not connected.
30+,29- P0_LVDS_VSYNC_OUT
VSYNC output for acq. path 0.
31+,35- P0_LVDS_CLK_OUT
Clock output for acq. path 0.
33+,32- P0_LVDS_HSYNC_OUT
HSYNC output for acq. path 0.
34+,38- LVDS_AUX_IN1
M_AUX_IO5
M_DEV0/
M_DEV1
LVDS auxiliary signal (input), shared between both acquisition
paths for trigger input (trigger controller 3 on acq path 0; 3 or 1
on acq path 1) or user input, and dedicated to acquisition path 1
for timer clock input or quadrature input bit 1.
36
GND
Ground.
37
P0_TTL_AUX_IO_1
M_AUX_IO9
M_DEV0
TTL auxiliary signal (input/output) for acquisition path 0, which
supports: timer output (M_TIMER1/M_TIMER4 on M_DEV0),
trigger input (trigger controller 1 on acq path 0), user input, or
user output (M_USER_BIT3).
39
TTL_AUX_IO_0
M_AUX_IO2
M_DEV0/
M_DEV1
TTL auxiliary signal (input/output), shared between both
acquisition paths for trigger input (trigger controller 2 on acq path
0; 2 on acq path 1), user input, or user output (M_USER_BIT4),
and dedicated to acquisition path 0 for timer output (M_TIMER2
on M_DEV0).
40
GND
Ground.
41
GND
Ground.
42
NC
Not connected.
43
TTL_AUX_IO_1
M_AUX_IO3
M_DEV0/
M_DEV1
TTL auxiliary signal (input/output), shared between both
acquisition paths for trigger input (trigger controller 3 on acq path
0; 3 on acq path 1), user input, or user output (M_USER_BIT5),
and dedicated to acquisition path 1 for timer output (M_TIMER2
on M_DEV1).
44
GND
Ground.
*. These MIL constants represent the signals as of MIL 10. The signals that were previously represented by M_HARDWARE_PORTn became represented by
M_AUX_IOn (where the value of n remained the same between the constants). For a complete list of changes between previous MIL versions and MIL 10,
see
MILSoliosCameraLinkIOConversionTable
within
MIL Release Notes
.
Pin
Hardware signal name
MIL constant
for auxiliary
signal
*
Digitizer
device number
for auxiliary
signal
Description
Содержание Solios eV-CL
Страница 1: ...Matrox Solios eV Installation and Hardware Reference Manual no Y11113 101 0300 January 15 2014...
Страница 22: ...22 Chapter 1 Introduction...
Страница 66: ...66 Chapter 4 Matrox Solios eV CL hardware reference...
Страница 119: ...Limited Warranty Refer to the warranty statement that came with your product...
Страница 120: ......