108 Appendix C: Matrox 4Sight GPm (Ivy Bridge) BIOS reference
Dynamic cTDP Configuration submenu
The
Dynamic cTDP Configuration
submenu allows you to configure the
dynamic cTDP (Configurable Thermal Design Power) parameters. This submenu
allows you to set the parameters to dynamically limit processor power
consumption based on temperature.
Text Mode Resolution
This item allows you to set the console text mode resolution.
AUTO*
Force 80X25
Force 80X24 (DEL
First Row)
Force 80X24 (DEL
Last Row)
ACPI SPCR Table
This item allows you to enable/disable the serial port console redirection ACPI table.
By selecting
Enabled
, information about the serial port redirect settings is formatted to ensure a seamless
transition between the firmware console output and Windows emergency management services (EMS)
output. If using Windows EMS, this feature must be enabled for terminal emulation to work.
By selecting
Disabled
, the information is not formatted to best match Windows EMS output.
Enabled
Disabled*
Item
Meaning
Options
Item
Meaning
Options
Dynamic cTDP
This item allows you to ‘disable the configuration TDP or allow the BIOS to dynamically change the cTDP at
runtime.
This item must be set to
BIOS controlled
to access any of the following items.
Disabled*
BIOS Controlled
VR12 Monitor
This item allows you to enable or disable the temperature sensor of the VR12 device.
Disabled*
Enabled
VR12 High Limit
This item allows you to set the temperature, in Celsius, at which to decrease the cTDP to cool down the
system. Set this value between 10 and 150.
If the temperature sensor of either the VR12 device or the TS sensor go above their respective High Limits,
the cTDP will decrease to the level specified in
Config TDP Level1
, found in the
Power menu --> Config TDP
Configurations
sub-submenu.
This item is only accessible when
VR12 Monitor
is set to
Enabled
.
VR12 Low Limit
This item allows you to set the temperature, in Celsius, at which to increase the cTDP to the boot value. Set
this value between 10 and 150.
If the temperature sensors of both the VR12 device and the TS sensor go below their respective Low Limits,
the cTDP will increase to the level specified in
Configurable TDP BOOT Mode
, found in the
Power menu -->
Config TDP Configurations
sub-submenu.
This item is only accessible when
VR12 Monitor
is set to
Enabled
.
Содержание 4Sight GPm
Страница 1: ...Matrox 4Sight GPm Installation and Hardware Reference Manual no Y11309 101 0252 July 31 2017 ...
Страница 9: ...Chapter 1 Before you begin This chapter introduces you to the key features of Matrox 4Sight GPm ...
Страница 87: ...Appendix C Matrox 4Sight GPm Ivy Bridge BIOS reference This appendix describes the BIOS Setup Utility ...
Страница 124: ...124 Appendix C Matrox 4Sight GPm Ivy Bridge BIOS reference ...
Страница 162: ...162 Appendix E Operating system recovery ...
Страница 166: ...166 Appendix F Listing of Matrox 4Sight GPm units ...
Страница 174: ...Limited Warranty Refer to the warranty statement that came with your product ...