9.16 emerGeNCy SToP SWiTCH rePlaCemeNT
1) Turn off power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.12.
3) Use a Phillips screwdriver to remove two screws, one from each side of the red button (Figure A).
4) Lift the button from bracket by pulling one side out at a time (Figure B).
5) Use a Phillips screwdriver to remove two screws, one from each side of the mounting bracket (Figure C).
6) Turn the bracket and use a straight screwdriver or pliers to compress each end of the switch and release it from the bracket (Figures D & E).
7) Reverse Steps 1-6 to install a new emergency stop switch.
NOTE:
Make sure the new switch has the same orientation as the old one
when installing, and that the wires are properly connected.
fiGUre a
fiGUre b
fiGUre C
fiGUre d
fiGUre e