19
5.8 maNaGer mode - Tab 7
fUNCTioN & defaUlTS
deSCriPTioNS
modified
Altitude
Default: 5000 ft
This option controls the default altitude used in
the fitness test score calculations.
Asset Management
Default: Off
This option allows the fitness club to collect the
machine data to a PC server.
ON or OFF
Virtual Active
Default: ON
This option controls the Virtual Active function. ON
Belt Stop
Default: Off
This option is to check the running belt to see
if a user is there. If there is no user, and the
status is over the default time, the machine will
enter into a pause mode for 5 minutes. If no
user is present within 5 minutes, the display will
return to the start up screen.
OFF, 30, 60, or 90
maNaGer mode
Other
CHaPTer 5: maNaGer mode