37
8.12 TroUbleSHooTiNG - No PoWer To THe CoNSole
1) SymPTom:
a. The unit is not getting power from the outlet.
b. The MCB is not getting power from the power receptacle.
c & d. The power switch and MCB LEDs are lit, but there is no power to the console.
2) SolUTioN:
a. Check to see if the power switch is lit. If it is not, plug the power cord into a known working outlet and re-test.
- If the power switch is still not lit, replace the power switch, receptacle, and / or the power cord.
b. Remove the motor cover and check to see if LED +12V (DSP4) is lit on the MCB (Figure A).
- If the LED +12V is not lit, check the incoming AC voltage to the MCB.
- Replace the MCB if all power components are OK, and there is AC volts to the MCB.
c. If LED +12V is lit, check the switch on the back of the LMM Board (Figure B).
- If the unit has a power board (Figure C), the switch should be towards the left.
- If the unit does not have a power board, the switch should be towards the right .
d. If LED +12V is lit, check the connection of the console communication cable.
- If the console communication cable is connected correctly, D18 on the console UCB should be lit.
- If D18 on the console UCB is not lit, replace the console communication cable.
- If D18 on the console UCB is lit, but there is still no power to the console, replace the console.
PoWer SWiTCH iS oN, bUT THe CoNSole HaS No diSPlay
fiGUre b
fiGUre a
CHaPTer 8: TroUbleSHooTiNG
fiGUre C
Содержание T7xe-04
Страница 1: ...T 7 x e 0 4 T r e a d m i l l S ER V I C E MA N U A l...
Страница 4: ...1 1 1 Serial Number Location Chapter 1 Serial number Location...
Страница 30: ...27 8 1 Electrical DiagramS Chapter 8 Troubleshooting...
Страница 32: ...29 8 1 Electrical Diagrams CONTINUED UCB Little Board Wire Chapter 8 Troubleshooting Hand Pulse Wire...
Страница 82: ...79 NOTES...