DEDICATED CIRCUIT AND ELECTRICAL INFO

A “Dedicated Circuit” means that each outlet you plug into should not have anything else 

running on that same circuit. The easiest way to verify this is to locate the main circuit breaker 

box, and turn off the breaker(s) one at a time. Once a breaker has been turned off, the only 

thing that should not have power to it are the units in question. No lamps, vending machines, 

fans, sound systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual 

neutral/ground connection coming from it, and terminating at an approved earth ground. 

You cannot “jumper” a single neutral/ground from one circuit to the next.

ELECTRICAL REQUIREMENTS

For your safety and to ensure good unit performance, the ground on this circuit must 

be non-looped (isolated). Please refer to NEC article 210-21 and 210-23. Any alterations 

to the standard power cord provided could void all warranties of this product.
The 3x, 5x and 7xe cycles are designed to be self-powered and do not require an external power supply 

source to operate.  Without an external power supply, the console’s start-up time may be delayed.

110 V UNITS

All Matrix 110 V cycles require the use of a 100-125 V, 60 Hz and a 15 A “Dedicated 

Circuit”, with a non-looped (isolated) neutral/ground for power. These cycles can 

be daisy-chained together with up to 4 units per 15 A circuit. This outlet should be 

a NEMA 5-15R and have the same configuration as the plug. No adapter should be 

used with this product. Matrix daisy-chain cord adapters are sold separately.

220 V UNITS

All Matrix 220 V cycles require the use of a 216-250 V, 50 Hz and a 15 A “Dedicated 

Circuit”, with a non-looped (isolated) neutral/ground for power. These cycles can 

be daisy-chained together with up to 4 units per 15 A circuit. This outlet should be 

a NEMA 6-15R and have the same configuration as the plug. No adapter should be 

used with this product. Matrix daisy-chain cord adapters are sold separately.

GROUNDING INSTRUCTIONS

The unit must be grounded if connected to a power supply source. If it should 

malfunction or breakdown, grounding provides a path of least resistance for 

electric current to reduce the risk of electric shock. The unit is equipped with a cord 

having an equipment-grounding conductor and a grounding plug. The plug must 

be plugged into an appropriate outlet that is properly installed and grounded in 

accordance with all local codes and ordinances. If the user does not follow these 

grounding instructions, the user could void the Matrix limited warranty.

ADDITIONAL ELECTRICAL INFO

In addition to the dedicated circuit requirement, the proper gauge wire 

must be used from the circuit breaker box, to each outlet that will have 

the maximum number of units running off of it. If the distance from the 

circuit breaker box to each outlet, is 100 ft (30.5 m) or less, then 12 gauge 

wire should be used. For distances greater than 100 ft (30.5 m) from the 

circuit breaker box to the outlet, a 10 gauge wire should be used.

ENERGY SAVING / LOW-POWER MODE

All units are configured with the ability to enter into an energy saving / low-

power mode when the unit has not been in use for a specified period of 

time. Additional time may be required to fully reactivate this unit once it has 

entered the low-power mode. This energy saving feature may be enabled 

or disabled from within the ‘Manager Mode’ or ‘Engineering Mode.’

WARNING!

• Connect this exercise product to a properly grounded outlet only.
• Never operate product with a damaged cord or plug even if it is working 

properly. Never operate any product if it appears damaged, or has been 

immersed in water. Contact Customer Tech Support for replacement or repair.

Failure to follow these specifications can cause damage 

to your product and can void the warranty:

• All video and power outlets must be functional the day of delivery 

/ assembly of the product. The client is responsible for any 

additional installation charges associated with return visits.

• Electrical supply may fluctuate in your area. To ensure stable 

performance of the product, use the proper gauge wire.

DANGER!

Improper connection of the equipment-grounding conductor can result in a risk 

of electric shock. Disconnect the power cord from this equipment and check with 

a qualified electrician or serviceman if you are in doubt as to whether the product 

is properly grounded. Do not modify the plug provided with the product. If it 

will not fit the outlet, have a proper outlet installed by a qualified electrician.

POWER REQUIREMENTS

North American and 

European power 

cord plugs shown. 

Depending on your 

country, the plug 

type may vary.

110 NEMA 5-15P 

PLUG (N.A.)

220 NEMA 6-20P 

PLUG (N.A.)

EURO PLUG 

(EUROPE)

Содержание R3xm

Страница 1: ...R3xm...

Страница 2: ...2...

Страница 3: ...operate where aerosol spray products are being used or when oxygen is being administered Close supervision is necessary when used near children This equipment is not intended for use by persons with...

Страница 4: ...it is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with a...

Страница 5: ...er PARTS INCLUDED F F 1 Main Frame F F 1 Rear Stabilizer Tube F F 1 Front Stabilizer Tube F F 1 Rear Frame Handle F F 1 Rear Frame Cover F F 1 Console Mast F F 1 Console Handlebars F F 1 Front Shroud...

Страница 6: ...USTMENT LEVER REAR FRAME HANDLE REAR STABILIZER TUBE REAR FRAME COVER MAIN FRAME CONSOLE CONSOLE MAST PULSE GRIPS RESISTANCE TOGGLES PEDALS CRANK ARM ADJUSTMENT LEVER FRONT SHROUD COVER FRONT STABILIZ...

Страница 7: ...ware Bag x2 Description Qty A B Bolt Flat Washer 8 8 Torque Values A 40 Nm 30 ft lb C D E F Black Red Hardware Bags Description Qty C D E F Bolt black Screw Bolt chrome Tooth Washer 2 2 4 4 Torque Val...

Страница 8: ...Hardware Bags Description Qty G D Bolt Screw 4 4 Torque Values G 40 Nm 30 ft lb 4 Blue Hardware Bag Description Qty H I Bolt Flat Washer 4 4 Torque Values H 77 Nm 57 ft lb H I Hold lever closed while...

Страница 9: ...are Bag Description Qty J K L M Nut pre attached Bolt Wavy Washer Spring Washer 1 4 4 4 K L M Connect cables Use clamp to secure cable Clamp over white sticker on cable Rotate seat 80 Push air cylinde...

Страница 10: ...10 6 N Orange Hardware Bag Description Qty N Bolt 2 7 O Pre Installed Hardware Description Qty O Bolt 5 Torque Values Pedals 55 Nm 41 ft lb ASSEMBLY COMPLETE...

Страница 11: ...onal help if necessary when moving Failure to follow these instructions could result in injury POWER If the equipment is powered by a power supply the power must be plugged into the power jack which i...

Страница 12: ...ccurate Over exercising may result in serious injury or death If you feel faint stop exercising immediately SEAT ROTATION 1 Pull up seat rotation lever B from seated or standing position 2 Slowly rota...

Страница 13: ...y contain important information If unreadable or missing contact your MATRIX dealer for a replacement 4 MAINTAIN ALL EQUIPMENT Preventative maintenance is the key to smooth operating equipment as well...

Страница 14: ...14 CRANK MAINTENANCE 1 2 14 mm 11 8 Nm 8 7 ft lb Reassemble lever Lever must be in locked position before tightening M6 handle hardware Repeat on other side 3 M6 10 mm...

Страница 15: ......

Страница 16: ...R3xm Frame 2017 Johnson Health Tech Part 1000402786 Rev 1 2 A...

Отзывы: