The DIRECT DOOR communicates with the COSEC Monitor
application over the TCP/IP network. The PANEL DOOR
Controller communicates with PANEL in either of the following
two ways:
1. Serial port communication using the RS 485 interface.
2. Ethernet based packet communication using the LAN
interface.
Though the PANEL DOOR Controller supports both RS 485 and
Ethernet communication ports, only one of the two interfaces
can be activated through configuration.
The Ethernet port uses standard IP address scheme to identify
the Controller and they can be changed depending on the site
requirement.
The RS 485 address on the PANEL DOOR is set using the 5
DIP switches located at the rear of the DOOR enclosure and
they support address range of 00 to 31. On the other hand, the
DIP switches on the DIRECT DOORs are used to default the
various settings on the DIRECT DOOR as explained in the
COSEC System manual.
The COSEC Access control system is designed to support up to
32 COSEC PANEL DOORs using RS485 communication under
one PANEL and 75 PANEL DOORs with Ethernet interface.
However, the system supports a total of 75 PANEL DOORs in a
heterogeneous network under one PANEL.
Mounting and Wiring the COSEC DOOR
Before installing the COSEC DOOR:
The COSEC DOOR has been designed to be mounted on a wall
in a single box without any additional enclosure.
Содержание Cosec Door
Страница 1: ...SE C UR I T Y S OL UT I ON S COSEC DOOR Quick Start ...
Страница 2: ......
Страница 3: ...COSEC DOOR Door Controller Quick Start S E CUR I TY S OLU T ION S ...
Страница 15: ...the following are the connection diagrams for the serial and the wiegand readers ...
Страница 22: ...DOOR Mounting Guide ...
Страница 30: ......
Страница 31: ......