initialize the IP settings, Password and System
Parameters of the DIRECT DOOR to factory defaults.

2.

The Ethernet RJ45 connector is located just above the
terminal strip on the back of the Door Controller. Connect
the male RJ45 connector here in the event of the
DIRECT DOORs or the Ethernet connectivity option
being used for the PANEL DOORs.

Ethernet Cable

Standard DOOR

Premium DOOR

Step 8:

 Mounting the Door Controller

Once all the connections have been completed it is time to
mount the door controller unit next to the access point such
as a door or turnstile as mentioned earlier.
Drill holes in the wall for insertion of the screws provided

with

the door controller. The holes are to be drilled in

accordance

with the following dimensions of the mounting plate of

the

door controller unit.

Содержание Cosec Door

Страница 1: ...SE C UR I T Y S OL UT I ON S COSEC DOOR Quick Start ...

Страница 2: ......

Страница 3: ...COSEC DOOR Door Controller Quick Start S E CUR I TY S OLU T ION S ...

Страница 4: ...OSEC system you may refer the COSEC System Manual a copy of which is available on the CDROM Before You Start Verify Package Content Unpack the system Make sure that your package contains all the below items If any item is missing or damaged please contact the source from where you have purchased the system COSEC DOOR Unit Quick Start and User Card Adapter 12VDC Country Specific Four Screws M 7 30 ...

Страница 5: ... DOOR configuration has limited functionalities compared to the PANEL DOOR configuration as explained in the COSEC System manual The COSEC PANEL DOOR Controller supports the following options 1 Ethernet and RS485 communication port LCD Display1 4 LEDs Status Alarm Allow Deny 2 Internal Readers 1 External Reader port 1 Door Relay 1 Aux input and output ports Touch sense Keypad1 Door Sense and Exit ...

Страница 6: ...with user With input device support this controller can read user credentials from card readers FP ID from finger print identification modules and PIN code input through the touch sense keypad In addition to the above the COSEC DOOR is designed to support Request for Exit through EXIT switch or through an Exit reader interfaced through RS232 Wiegand port The COSEC PANEL DOOR also provides an Aux i...

Страница 7: ...e site requirement The RS 485 address on the PANEL DOOR is set using the 5 DIP switches located at the rear of the DOOR enclosure and they support address range of 00 to 31 On the other hand the DIP switches on the DIRECT DOORs are used to default the various settings on the DIRECT DOOR as explained in the COSEC System manual The COSEC Access control system is designed to support up to 32 COSEC PA...

Страница 8: ...he COSEC DOOR Controller should be accessible for ease of installation and maintenance The DOOR Controller unit has inbuilt readers and thus it is mandatory that it should be installed next to the access point Select an ideal location using the following guidelines Stay away from electrical or communication devices DOOR Controllers must be located at a minimum distance of 2 m 6 feet from any high ...

Страница 9: ...g procedure as shown Step 3 Power Supply There are three options for providing the 12VDC 1 amp power input to the COSEC DOOR Controller A 2 conductor cable can be drawn from the terminals on the Power supply unit of the COSEC PANEL These can be connected to terminals 39 40 of the terminal strip on the COSEC DOOR Controller Up to 4 COSEC DOORs can be powered this way ...

Страница 10: ... 40 2 Connect the adapter giving an output of 12VDC 1 1 5A to the terminals 39 and 40 on the COSEC DOOR Controller unit However care must be taken to maintain the correct polarity T2 21 40 COM NC NO 0V 0V Lock Tamper COM Door STS In COM Aux In COM A B Shield 12VDC 0V 12V A B Shield Loop In Loop Out ...

Страница 11: ...erminal strip Here again care must be taken to maintain the correct polarity Door Controller 39 0 12V 40 COSEC DOOR PSBB Power should only be applied to the unit when all connections are completed and tested Step 4 Installing the COSEC DOOR Unit The following diagram illustrates a typical door layout Lock Device REX Reader Ethernet RS485 COSEC PANEL PANEL DOOR ...

Страница 12: ...rated Step 5 Connecting the Door Locking Device The lock NO COM NC and 12VDC terminals are located at terminal nos 21 through to 24 on the top right of the COSEC DOOR terminal strip The locking device output is controlled by the software according to preset parameters for allowing access or unlocking doors according to schedules and access levels The NO or NC output can operate DC powered locking ...

Страница 13: ...minal 25 to the Door locking device Step 6 Hooking up Inputs The COSEC DOOR has on board capacity of 4 inputs 2 in the case of a DIRECT DOOR configuration Except for the Request to Exit Input each input can be supervised with end of line resistors 4 7K ohm 19 20 30 29 Door Egress Common Door Status 4 7 K 4 7 K NC NO The maximum distance of one line is 600 m 2 000 feet with AWG 22 grade conductors ...

Страница 14: ...eaders 2 internal and one External The External reader port supports a single reader with Wiegand Serial interface To fully utilize Wiegand reader port a shielded 11 conductor cable 18 22 AWG is required The maximum recommended length of wiring is 500 feet per reader Connecting the Wiegand HID R10 RW100 Prox Reader The HID R10 and RW100 readers come with the Pigtail option which has color coded co...

Страница 15: ...the following are the connection diagrams for the serial and the wiegand readers ...

Страница 16: ...o the COSEC DOOR terminal strip as shown in the figure below The terminals on the back of the COSEC reader unit are numbered 1 through 11 15 depending on the reader as shown and are to be connected to the terminal strip of the DOOR using at least a 11 conductor 22 AWG cable ...

Страница 17: ... LED Red LED Beeper Hold COM Tamper RS 232 R RS 232 T Status LED Alarm LED Exit SW COM Rdr pwr COSEC READER FPR Terminal Strip of Door Controller The COSEC Mifare and the Proximity reader modules can be connected in the following ways depending on the kind on the interface type of the reader ...

Страница 18: ...Strip of Door Controller External Serial Reader 1 20 T1 COM NC NO GND D0 D1 DATA RTN Green LED Red LED Beeper Hold COM Tamper RS 232 R RS 232 T Status LED Alarm LED Exit SW COM Rdr pwr Terminal Strip of Door Controller External Wiegand Reader Connecting the red wire lead or power lead of a 5 VDC reader to the 12 VDC terminal may damage the reader ...

Страница 19: ...ication loop should be wired with Ethernet Category 3 double twisted pair network cable see cable specifications Belden 1227A or equivalent The RS 485 loop can operate at 115 200 baud under normal conditions To link COSEC PANEL DOORs 1 Connect the incoming RS 485 cable to the Loop IN A and B terminals 33 and 34 respectively The outgoing RS485 conductors will connect to the Loop Out A and B termina...

Страница 20: ...Also set the number of the door controller by setting the dip switch provided at the top right on the back of the PANEL DOOR Controller as shown DIP Switch to set the Physical RS485 address of the Door On the other hand the COSEC DIRECT DOOR configuration uses the DIP switches numbered 1 to 3 to ...

Страница 21: ...ctivity option being used for the PANEL DOORs Ethernet Cable Standard DOOR Premium DOOR Step 8 Mounting the Door Controller Once all the connections have been completed it is time to mount the door controller unit next to the access point such as a door or turnstile as mentioned earlier Drill holes in the wall for insertion of the screws provided with the door controller The holes are to be drille...

Страница 22: ...DOOR Mounting Guide ...

Страница 23: ...he nail grips in the holes Now place the mounting plate on the wall and mount it using the 4 wall mounting screws M 7 30 The Door Controller unit can now be fixed on to the mounting plate using the matching slots as a guide A matching slot is also provided on the bottom right of the Door Controller unit and the mounting plate for a screw as shown in the figure ...

Страница 24: ... Ethernet network Power up all the DOOR Controllers once after they have been defined and configured in the COSEC application as described in the COSEC System manual Also ensure that the PANELS if any on the network are also powered up prior to powering up the DOOR Controllers This is to ensure that the PANEL can start downloading the PANEL DOOR firmware to all DOORs on the network which have been...

Страница 25: ...et Date and Time Door Password To access the Admin functions press the ENT key on the DIRECT DOOR keypad and then press the numeric key 3 or scroll down to the Admin option and press the ENT key The system prompts for the admin user password as shown Enter the Admin user password default is 1234 MON 21 DEC 15 22 1 TA Options 2 HRD 3 Admin MON 21 DEC 15 22 Enter Password The following display appea...

Страница 26: ... IP address of the DIRECT DOOR press the Number key 1 to select the IP option or just press the ENT key The system will prompt for the new IP address as shown MON 21 DEC 15 22 MON 21 DEC 15 22 IP Address 192 168 50 50 New LAN Setting LAN Setting IP Address 192 168 50 50 New 010 001 050 100 To change the Subnet Mask of the DIRECT DOOR press the Number key 2 to select the SM option or scroll to the ...

Страница 27: ...ecting the COSEC DIRECT DOOR to the Monitoring PC Connect your computer s Ethernet port and the DOOR s Ethernet Port by using either of two below mentioned methods 1 Connect both the computer s and the DOOR s Ethernet port to an Ethernet hub with standard straight through Ethernet patch cables as shown Ethernet Switch DIRECT DOOR COSEC Monitor PC 2 Connect the computer s Ethernet port directly to ...

Страница 28: ...OR Controller as explained in the COSEC System Manual However the user needs to keep a note of the IP settings as set on the DIRECT DOOR as the same would have to be entered in the Network parameters section on the Doors option page of the COSEC application The PANEL DOORs on the other hand are assigned their IP addresses by the PANEL based on the Controller Network Parameters as defined in the Ne...

Страница 29: ...It is essential to maintain the polarity of the terminals while connecting the power supply options to the DOOR Controller ...

Страница 30: ......

Страница 31: ......

Страница 32: ... 912652630555 Fax 912652636598 E mail Info MatrixComSec com Factory 39 GIDC Waghodia 391760 Dist Vadodara India Ph 912668262056 57 Technical Support Ph 912668263172 73 Fax 912668262631 E mail Support MatrixComSec com www MatrixComSec com Version 3 July 2014 S E CUR I TY SOLU T ION S ...

Отзывы: