lower limit set (and shift combination is effective when pressed).
CRL (function word key
"Save"):
Not open
I-Set
Set the maximum output current of the power supply.
V-Set
Setting the output voltage of the power supply
Save
Store the relevant parameters of the power supply to the specified storage
location.
Recall
Set the power related settings parameters from the specified storage
location.
Shift
Composite key, combined with multi function key.
On/off
Control power output state
▲
Up conversion key (select menu item in menu operation, increase output
voltage at work interface)
▼
Down button (menu item is selected in menu operation, and output voltage
can be reduced at work interface).
Enter
Acknowledgement key
knob
Used to change the supply voltage and current setting.
4.2 Front Panel Operation Introduction
Before using this power supply, please understand the following basic introduction to
the key operation of front panel.
The C machine controls switching. When the operation mode changes, the output
parameters of the power supply will not be affected.
4.3 Voltage Setting Operation
The voltage setting range is between 0V and the maximum voltage setting. You can use
the following three ways to set the output voltage value through the front panel.
Method 1: after power supply is switched on, press voltage and key directly to change
the voltage setting value.
Method two: press the V-Set key + 0 to 9 numeric keys, and press the Enter button to
set the voltage value.
Method three: change the setting value of the voltage through the rotation of the
knob. (the knob is pressed to the inside, the screen flickers can rotate and set the
voltage and current. By pressing the knob, it can move the cursor position and press
the "Enter" button to confirm and exit the setting mode. If the "Iset or Vset" button is
pressed down, the knob will be locked.
4.4 Current Setting Operation
The setting range of constant current is between 0A and full rated output current.