background image

MSC-HD42L Product Manual

1 Getting Started

Congratulations on your purchase of a quality Matrix Switch Corporation product.  This section contains a 
general overview of device functionality and provides information to get you up and running quickly.  
Additional sections in this manual can be consulted for more detailed information on the subsystems and 
features of this product.

1.1 Device Connections

The 

MSC-HD42L

 comes with a power supply adapter and a documentation CD.  Additional cables and 

hardware are not usually provided.

Power supply adapter

 – A 5 volt 2 Amp power supply adapter is provided which is connected to the 

5.5mm OD 2.5mm ID coaxial connector on the device and plugged into a 100-240V 50/60Hz AC power 
source.

Ethernet connector (Optional)

 – Connect to a network switch with an Ethernet cable.  Required for 

accessing the web page interface, TCP/IP Mascot interface or for interfacing with remote control panels. 
A crossover cable can also be utilized for connecting directly to a computer or remote panel.

SDI Video Inputs

 – Connect SDI sources to input connectors using 75 Ohm Coax cable with BNC 

connectors designed for high speed SDI video applications.  Unused inputs can be left unconnected. 
Inputs with supported standard rate (3G, HD or SD) SDI signals will be auto re-clocked for reduced 
jitter.  Other non standard rates between 125 Mbit/s and 2.97 Gbit/s will be passed through without re-
clocking or jitter reduction.  Adaptive cable equalization on each input can equalize input signals from 
Belden type 1694A cables up to lengths of 120m (@3G), 140m (@HD) and 400m (@SD).

SDI Video Outputs

 – Connect SDI destinations to output connectors using 75 Ohm Coax cable with 

BNC connectors designed for high speed SDI video applications. Unused outputs can be left 
unconnected.  Outputs utilize standard SMPTE levels of 800mV peak-to-peak.

Sync Reference (Optional)

 – If switching on vertical sync pulse is desired, connect one of the Sync 

Reference connectors to a sync pulse signal (NTSC, PAL or tri-level) using 75 Ohm Coax with BNC 
connectors and the other Sync Reference connector can be used as a pass-through to additional properly 
75 Ohm terminated equipment or a 75 Ohm terminator should be installed.  If the sync reference 
functionality is not used, both connectors can be left unconnected.

RS-232 Serial (Optional)

 – If serial control is desired, using the 

Mascot 

 

 P

  rotocol

, connect a D9 female 

to male straight through cable to a control system, such as a computer.  Use 9600 bps 8N1 as the serial 
configuration and enable local echo to see typed characters.

External Button Control (Optional)

 – This device provides an external button control interface 

utilizing unused pins on the D9 serial connector.  Refer t

External Button Control

 for details.

1.2 Powering Up The Device

This device is not equipped with a power switch and is simply connected to the power supply adapter which is 
plugged into a suitable AC power source, to power it up.
Once the device is powered it goes through the following startup sequence:

5 second startup delay to allow for 

Power On Software Updates

.

Routing matrix is initialized to Preset 0 state (defaults to source 1 connected to all destinations).

The button control panel is initialized and buttons are illuminated to show the initial routing status.

Page 7 of 55

Copyright © 2013-2015 Matrix Switch Corporation

www.matrix-switch.tv

Содержание MSC-HD42L

Страница 1: ...atrix Switch Corporation MSC HD42L Product Manual Mini 4 input 2 output 3G SDI Video Router with Button Control Panel Revision 1 2 Page 1 of 55 2013 2015 Matrix Switch Corporation www matrix switch tv...

Страница 2: ...ITED TO ITS CONDITION QUALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corpor...

Страница 3: ...24 Updated External Button Control Pinout section Added External Button Control information for MSC HD42L 2014 03 17 Fixed some document cross references Minor text content and figure position change...

Страница 4: ...anging a connection 14 2 2 2 Loading a preset 14 2 3 Presets Tab 14 2 3 1 Loading Work Matrix from a source target 15 2 3 2 Saving Work Matrix to a target 15 2 3 3 Usage scenarios 15 2 4 Labels Tab 15...

Страница 5: ...nelRate Command 36 3 33 PClr Command 37 3 34 PsetNames Command 37 3 35 PSub Command 38 3 36 PView Command 38 3 37 Reboot Command 39 3 38 ReclkDis Command 39 3 39 RemoteSync Command 39 3 40 S Command 4...

Страница 6: ...5 4 0 to a previous version 50 5 Troubleshooting 51 5 1 Unknown IP address 51 5 2 No Ethernet link when connected to network switch 51 5 3 Unexpected reboots 51 6 Reference 52 6 1 Specifications 52 6...

Страница 7: ...m SD SDI Video Outputs Connect SDI destinations to output connectors using 75 Ohm Coax cable with BNC connectors designed for high speed SDI video applications Unused outputs can be left unconnected O...

Страница 8: ...of Matrix Switch Corporation devices Device Type Default IP Address Video Audio Routers 192 168 2 60 Remote Button Panels 192 168 2 64 Remote LCD Screen Panels 192 168 2 80 To access the web page int...

Страница 9: ...terface can be used for modifying labels Click the Save button to store any changes that are made Refer the Labels Tab section for more details 1 4 5 Presets There are 10 stored matrix routing presets...

Страница 10: ...d LAN environments In the event that remote device configuration or control is desired over public networks or the Internet it is strongly recommended that some form of inter network security is utili...

Страница 11: ...e panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router to control Video only and an additional 16x16 remote panel to control Aud...

Страница 12: ...ster to provide 3D support Devices must have the same matrix size Resulting 3D matrix is equal to the matrix size of a single device for example two 8x8 routers would result in one 8x8 3D router One r...

Страница 13: ...s to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 System...

Страница 14: ...stination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the Load...

Страница 15: ...Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab i...

Страница 16: ...for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to use...

Страница 17: ...ve name of the system up to 15 characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all...

Страница 18: ...on to control individual destinations of a 16x4 Router 16 source 4 destination Another usage scenario would be to have 2 separate panels control different levels of a Video Audio Router Control Mode S...

Страница 19: ...ommand Tab Figure 5 provides access to the Mascot protocol interface Commands are typed on the Command text entry line followed by pressing the Enter key to execute them The results will be displayed...

Страница 20: ...changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot...

Страница 21: ...hould be on in order to see what is typed Pressing the Enter key once connected should yield the prompt character 3 4 Command format Commands consist of a command name zero or more arguments separated...

Страница 22: ...NN where NN are 2 hex digits from 0 9 A F or a f Double quoted One or more characters surrounded by double quotes An Argument Single quoted One or more characters surrounded by single quotes An Argume...

Страница 23: ...es This following table shows possible error codes which may be returned in response to commands Error Message Description E01 Token too long A command name or string argument was too long E02 Invalid...

Страница 24: ...preset X DEST SRC LEVEL Perform a matrix connect operation Router systems and MSC GCP2U32 LCD panel only 3 9 Advanced command reference These additional commands consist of those which are not as com...

Страница 25: ...LVL1 LVL2 Query or assign button panel destination source offsets and levels to control Useful for configuring multiple panels to control different I O regions of a router PanelRate 2 1 RATE Set remo...

Страница 26: ...ry all destination names DestNames DEST Query destination names for all levels of a given destination DestNames DEST LEVEL Query the name of a specific destination and level DestNames DEST LEVEL LABEL...

Страница 27: ...iption DHCP Query DHCP enable DHCP 0 1 Set DHCP enable 0 to disable 1 to enable Examples to query and then enable DHCP DHCP 0 DHCP 1 3 14 E Command Routers and MSC GCP2U32 only Query or assign matrix...

Страница 28: ...control the Router device itself This setting is saved and recalled on power up Command Description FrameIP Query IP address of remote Router system to control FrameIP IP Set IP address of remote Rout...

Страница 29: ...ying and assigning the IP address IP 192 168 2 60 IP 192 168 2 61 3 20 LockStatus Command Routers only Query the video lock status and video rate of a Video Router s outputs This command is only suppo...

Страница 30: ...ng table Flag Information Fields in JSON data 1 Return names Destination Source and Preset destNames srcNames and psetNames 2 Return matrix routing state state 4 Return preset routing data psetData Th...

Страница 31: ...is OK updating from a remote router for example one or more remote routers disconnected or a general error remote router in error status for example respectively NAME Descriptive name of a level dest...

Страница 32: ...Carina Series routers only Protocol Version 2 4 Query or assign I O grouping This setting is saved and recalled on power up The I O grouping feature is used to combine multiple inputs and outputs Comb...

Страница 33: ...work configuration Maintaining the ability to access a device s web page and for Remote Panel devices to be able to communicate with Routers requires that the IP address is known valid and systems are...

Страница 34: ...mmand I O pairing is used for pairing destinations sources for 3D support When activated a router will appear to have half the number of physical destinations and sources A given matrix crosspoint cha...

Страница 35: ...termines which destination the button panel starts on 0 is used for no offset default The SRCOFS parameter is used likewise to assign a source offset The LVL1 and LVL2 parameters are used for modifyin...

Страница 36: ...l panel interface setting 0 disabled The second command enables the external panel interface 3 32 PanelRate Command Protocol Version 2 1 For changing remote button panel refresh rate When a button pan...

Страница 37: ...MSC GCP2U32 only Query or assign preset names Preset names are stored and recalled on power up Command Description PsetNames Query all preset names PsetNames PRESET Query a single preset name PsetName...

Страница 38: ...nd MSC GCP2U32 only View presets Displays the content of one or all presets The format of the returned output is 1 S1 S2 2 S1 S2 where the 1 and 2 are incrementing destination values followed by one o...

Страница 39: ...Usually used for creating a 3D matrix from two router systems which will result in one router controlling the left 3D channels and the other router controlling the right channels When enabled this op...

Страница 40: ...h has a 2nd level break away which is routed from source 4 3 41 Sierra Command Carina Series routers only Protocol Version 2 4 Queries or assigns Sierra Video Systems protocol on serial port This sett...

Страница 41: ...mes 1 2 AudSrc1 SrcNames 1 2 The first 3 example commands are query commands The last assigns an empty string to the second level of the first source thereby indicating that the first level label shou...

Страница 42: ...ould be received on a Carina series system with older firmware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 45 Vars Command Protocol Ve...

Страница 43: ...ower cycles Command Description W PRESET Write current matrix routing state to PRESET Example to save state to preset 1 W 1 3 47 WebPass Command Assign a web password to password protect the web page...

Страница 44: ...lue 0 can be used for SRC to Mute a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state...

Страница 45: ...e TFTP transfer has to occur within this period after power cycling the device This means the PC needs to be in close proximity of the device remote power control be possible or coordination with some...

Страница 46: ...IP network as the device if not already Make sure that there are no IP conflicts with the PC or device 3 Prepare the TFTP program to transfer the firmware file to the device but do not initiate the t...

Страница 47: ...ands to navigate to the folder where the firmware file is located 4 Type the following command to prepare the TFTP transfer but don t hit ENTER yet tftp 192 168 2 59 put MatrixFirmware x x x hex 5 Mak...

Страница 48: ...ype quit and ENTER and start over from step 3 4 2 4 Linux The tftp application can easily be installed with your distributions package manager from a terminal below are some example commands for vario...

Страница 49: ...ystem s settings will not be retained after the software update This means that all input output labels networking configuration and the Ethernet MAC address will be lost and will need to be re entere...

Страница 50: ...grading from version 5 4 0 to a previous version If downgrading from Carina firmware version 5 4 0 or newer to a version prior to 5 4 0 the system configuration will not be retained Please contact Mat...

Страница 51: ...nal application once connected and a prompt character should be displayed Type the following commands pressing ENTER after each one to get the IP address and netmask ip netmask 5 2 No Ethernet link wh...

Страница 52: ...ctor type BNC Data Types SMPTE 259 292 424 Data Rates 19 Mbit s through 3 0 Gbit s Re clocking Data Rates 270 Mbit s 1 485 Gbit s 2 97 Gbit s Input Output Return Loss 15dB HD 12dB 3G Input Level 800 m...

Страница 53: ...button pins in reference to the ground pin If the voltage is 3 3V then it is configured for active low if it measures 0V then it is active high Button interface signals Active Low Connect button pins...

Страница 54: ...eset Numbered starting from 0 Preset 0 is special in that it is recalled on system startup Remote Panel Matrix Switch Corporation Remote Panels connect to Router devices for remote control with touch...

Страница 55: ...ial Authorization RMA number which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modi...

Отзывы: