Matheson LeakHunter Plus 8066 Скачать руководство пользователя страница 2

DISCLAIMER 

 
Matheson Gas Products makes no representations or warranties with respect to the contents or use of 
this manual and specifically disclaims any express or implied warranties of merchantability or fitness for 
any particular purpose.  Further Matheson reserves the right to make changes to the instrument and this 
manual, at any time, without obligation to notify any person or entity of such revisions or changes. 

 
 

LIMITED WARRANTY

 

 

This equipment is sold by Matheson Gas Products (Matheson) under the warranties set forth in the 
following paragraphs.  Such warranties are extended only with respect to the purchase of this equipment 
directly from Matheson or Matheson's Authorized Agent as new merchandise and are extended to the 
first Buyer thereof other for than the purpose of resale. 
 
For a period of one year from date of original delivery (ninety days in corrosive service) to Buyer or to 
Buyer's order, this equipment, is warranted to be free from functional defects in materials and 
workmanship and to conform to the description of this equipment contained in this manual and any 
accompanying labels and/or inserts, provided that this equipment is properly operated under the 
conditions of normal use and that regular and periodic maintenance and service is performed or replace-
ments are made in accordance with the instructions provided. Expendable parts of this equipment are 
similarly warranted to be free from functional defects in materials and workmanship and to conform to the 
description of this equipment contained in this manual and any accompanying labels and/or inserts.  The 
foregoing warranties shall not apply if the equipment has been repaired other than by Matheson or a 
service facility designated by Matheson, or if this equipment has not been operated and maintained in 
accordance with written instructions provided by Matheson, or has been altered by anyone other than 
Matheson, or if the equipment has been subject to abuse, misuse, negligence or accident. 
 
Matheson's sole and exclusive obligation and the Buyer's sole and exclusive remedy under the above 
warranties is limited to repairing or replacing, free of charge, at Matheson's sole discretion, the equipment 
or part which is telephonically reported to be a problem to the local Matheson Branch Location, and which 
if so advised, is returned with a written statement of the observed deficiency, not later than seven days 
after the expiration of the applicable warranty, to the Matheson Gas Equipment Technology Center during 
normal business hours, transportation charges prepaid, and which, upon examination, is found to comply 
with the above warranties.  Return trip transportation charges for the equipment or part shall be paid by 
the Buyer. 
 

MATHESON SHALL NOT BE OTHERWISE LIABLE FOR ANY DAMAGES INCLUDING BUT NOT 
LIMITED TO INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, OR SPECIAL DAMAGES, 
WHETHER SUCH DAMAGES RESULT FROM NEGLIGENCE, BREACH OF WARRANTY OR 
OTHERWISE. 
 
THERE ARE NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE 
WARRANTIES HEREINABOVE SET FORTH.  MATHESON MAKES NO WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE 
EQUIPMENT OR PARTS THEREOF. 
 
ACCEPTANCE OF THE EQUIPMENT BY THE FINAL BUYER INDICATES THE FINAL BUYER'S 
ACCEPTANCE OF ALL WARRANTIES AND LIMITATIONS SET FORTH ABOVE. 

 

Matheson Gas Products 

166 Keystone Drive 

Montgomeryville, PA  18936 

Ph. 215-641-2700 

Fax 215-641-2714 

INT-0124-XX                     2

 

Содержание LeakHunter Plus 8066

Страница 1: ...LeakHunter Plus 8066 User Manual LeakHunter Plus LTR REVISION DATE BY A1 Release for Prod 11 02 95 CJC B1 Revise Spares List 05 23 96 BT INT 0124 XX...

Страница 2: ...anties shall not apply if the equipment has been repaired other than by Matheson or a service facility designated by Matheson or if this equipment has not been operated and maintained in accordance wi...

Страница 3: ...conductivity that differs from that of the ambient air on which it was zeroed The instrument is normally zeroed in ambient air comprising a mixture of approximately 78 nitrogen and 21 oxygen Hence th...

Страница 4: ...nge extension nozzle Probe clip and template AC power adapter and battery charger Battery User manual Cleaning wipe Extended probe The clip attaches permanently to the rear of the instrument The probe...

Страница 5: ...n in Figure 1 3 Peel off the paper that protects the adhesive on the back of the clip Assembly aid Probe clip Rear of case Figure 2 Probe clip template 4 Carefully position the clip in the position de...

Страница 6: ...ctable Functions Peak hold Zero Calibrate Gas type nozzle type Response time Approximately 1s Recovery time Approximately 1s Audio Signal proportional to leak rate Diagnostics Battery low indication D...

Страница 7: ...d in the same mode as it will be used 3 4 Peak hold Press PEAK HOLD to select and display the Peak Hold symbol on the screen In this mode the instrument shows the highest positive or negative value me...

Страница 8: ...zzle Present symbol The same operations should be carried out when attaching or removing the extended probe supplied as part of the 8066 3 8 Battery low This symbol becomes visible when the battery is...

Страница 9: ...and hold ZERO then press PEAK HOLD You will see the displayed exponent change with the change of sensitivity For instance with ml sec units successive exponents will be 5 most sensitive range 4 and 3...

Страница 10: ...are disabled 4 Present a standard leak or concentration of gas to the instrument 5 Set the display bargraph and exponent to read the standard leak flow rate or concentration use PEAK HOLD to increase...

Страница 11: ...pter is for indoor use only The battery charger is for indoor use with Ni Cad batteries only Do not attempt to recharge other types of battery as damage or injury may result Recharging time is 16 hour...

Страница 12: ...nd probe Instrument will not power up Depleted battery Replace battery or use AC power adapter Wrong connector used on AC power adapter Make sure smaller female connector is used on unit 7 2 Error ind...

Страница 13: ...05 6 0E 04 2 1E 08 1 6E 02 2 Neon 41 5 80E 05 3 5E 03 1 2E 07 9 3E 02 Xenon 41 5 81E 05 3 5E 03 1 2E 07 9 3E 02 3 R11 35 6 84E 05 4 1E 03 1 5E 07 1 0E 03 R12 30 7 90E 05 4 7E 03 1 7E 07 1 3E 03 R21 3...

Страница 14: ...Units Peak hold Battery low Leak rate bargraph mantissa Leak rate exponent Not used Default calibration in use Nozzle present LeakHunter Plus 8066 ZERO PEAK HOLD GAS GROUP 1 2 POWER INT 0124 XX 14...

Отзывы: