Matco Tools MT1724 Скачать руководство пользователя страница 3

MT1724 

Rev. 06/17/16

OPERATION

Always turn off the air supply, drain hose of air pressure 

and detach tool from air supply before installing, removing 

or adjusting any part or accessory on this tool, or before 

performing any maintenance on this tool. 

The Quick Change Chuck is designed to accept only 0 .401

"

 diameter round 

shank chisels . Always place the chisel in the hammer's quick change 
chuck retainer and hold the tool down to the work before operating . 
Damage to the tool or the retainer may result if this precaution is not 
followed .
The chisel retainers are not designed for complete safety against 
accidental release of chisels or hammers . To avoid injury, the throttle 
must never be depressed unless the chisel is held firmly against the work 
place . When tool is not in actual use, the chisel must be removed . During 
operation, safety goggles should always be used to guard against flying 
rust and chips . When using tool, regulate the speed so that the chisel is not 

being driven out of the cylinder . If piston is allowed to strike the cylinder 
wall, internal damage will result .
To change chisel, pull back on quick change chuck collar and insert chisel . 
Release chuck collar to lock in the chisel .
To regulate power, gently pull the variable speed trigger for minimum to 
maximum power .

NOTE:  During operation, safety goggles should always be 

worn to guard against flying debris (users and bystanders).

MT1724 LONG BARREL AIR HAMMER

AIR SUPPLY

Tools operate on a wide range of air pressures. It is recommended 

that air pressure measures 90 psig at the tool with the trigger fully 

depressed and no load applied to the tool. Higher pressure (over 

90 psig; 6.2 bar) raises performance beyond the rated capacity of 

the tool, which will shorten tool life and could cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water in 

the air line will cause damage to the tool. Drain the water from 

air lines and compressor prior to running tool. Clean the air inlet 

filter screen  weekly. The recommended hookup procedure can 

be viewed in FIG. 1.
The air inlet used for connecting air supply has standard 1/4" NPT. 

Line pressure should be increased to compensate for unusually 

long air hoses (over 25 feet). Minimum hose diameter should be 

3/8" I.D. and fittings should have the same inside dimensions and 

be tightly secured. 
Ensure an accessible emergency shut off valve has been installed 

in the air supply line and make others aware of its location.

TROUBLESHOOTING

Other factors outside the tool may cause loss of power or erratic 

action. Reduced compressor output, excessive drain on the air line, 

moisture or restrictions in air pipes or the use of hose connections 

of improper size or poor conditions may reduce air supply. Grit or 

gum deposits in the tool may cut power and may be corrected 

by cleaning the air strainer and flushing out the tool with gum  

solvent oil or an equal mixture of SAE #10 and kerosene. If outside  

conditions are in order, disconnect tool from hose and take tool to 

your nearest authorized service center.

LUBRICATION AND  MAINTENANCE

Lubricate the air motor daily with high quality air tool oil. If no air 

line oiler is used, run 1/2 oz. of oil through the tool. The oil can 

be squirted into the tool air inlet or into the hose at the nearest  

connection to the air supply, then run the tool. A rust inhibitive oil 

is acceptable for air tools.

WARNING:

 After an air tool has been lubricated, oil will discharge 

through the exhaust port during the first few seconds of operation. 

The exhaust port must be covered with a towel before applying 

air pressure to prevent serious injury.

FEATURES

•    New and improved metal valve design gives this air hammer longer life and more power than previous generation .
•    Fluted barrel for increased performance in use .
•    Rubber comfort grip .
•    Positive action trigger for precise control .
•    Includes quick change retainer .
•    Bottom exhaust designed to direct air away from work .

FIG. 2

REGULATOR

AIR INLET

QUICK 
CHANGE
CHISEL 
RETAINER

TRIGGER

FIG. 1

Drain Daily 

Regulator 

Oiler 

Quick Coupler 

Leader 

Hose 

  

Nipple 

 Do Not Install

Quick Coupling

Here

  

  

 

Nipple 

  

Filter 

  

 

Air Supply 

  

 

Whip Hose 

Содержание MT1724

Страница 1: ...dust masks that are specially designed to filter out microscopic particles S P E C I F I C A T I O N S Operating Instructions Warning Information Parts Breakdown Copyright Professional Tool Products 2...

Страница 2: ...See instructions for correct set up Keep tool out of reach of children Air powered tools can vibrate in use Vibration repetitive motions or uncomfortable positions over extended periods of time may be...

Страница 3: ...air inlet filter screen weekly The recommended hookup procedure can be viewed in FIG 1 The air inlet used for connecting air supply has standard 1 4 NPT Line pressure should be increased to compensate...

Страница 4: ...ee of charge and returned to you freight prepaid This warranty gives you specific rights You may also have other rights which vary from state to state The foregoing obligation is Matco s sole liabilit...

Страница 5: ...1 13 RS848013 Spring 1 14 RS171814 Trigger Button 1 15 RS181112 Metal Valve Block Assembly 1 20 RS848019 Piston 1 REF NO PART NO DESCRIPTION QTY 21 RS172421 Cylinder 1 22 RS171822 Comfort Grip 1 23 M...

Страница 6: ...los que son espec ficamente dise ados para filtrar las part culas microsc picas E S P E C I F I C A C I O N E S Instrucciones de Operaci n Inforaci n de Advertencia Revisi n de Refacciones Copyright P...

Страница 7: ...da inos para sus manos y brazos Suspenda el uso de la herramienta si experimente molestias estremecimiento o dolor Antes de continuar us ndola solicite el consejo m dico Resbalarse tropezarse y o cae...

Страница 8: ...resi n en la l nea para compensar por las mangueras de aire incomunmente largas mayores de 25 pies El di metro m nimo de la manguera debe de ser de 3 8 de di metro interior y los herrajes deben contar...

Страница 9: ...e obra se reparar la herramienta libre de cargos y sta ser devuelta a usted con flete prepagado Esta garant a le proporciona ciertos derechos Usted puede tener tambi n otros derechos los cuales var an...

Страница 10: ...les masques poussi re qui sont con us pour filtrer les particules microscopiques S P C I F I C A T I O N S Instructions de fonctionnement Avertissement Pi ces Copyright Professional Tool Products 2016...

Страница 11: ...ra sus manos y brazos Suspenda el uso de la herramienta si experimente molestias estremecimiento o dolor Antes de continuar us ndola solicite el consejo m dico Une glissade un tr buchage et ou une chu...

Страница 12: ...ns le cas de boyaux air exceptionnellement longs plus de 25 pieds Le diam tre int rieur minimal du boyau doit tre de 3 8 po Les raccords doivent avoir le m me diam tre int rieur et tre serr s solideme...

Страница 13: ...ourn port pay Cette garantie vous donne des droits particuliers Vous pouvez aussi avoir d autres droits qui varient d un tat l autre Cette obligation est la seule responsabilit de Matco dans le cadre...

Отзывы: