background image

024-03 - Gas cooker

8

WARNING

It is not possible to adjust nominal capacity in advance. 

Checking power rating when using LP
gas

Check that the type of nozzles used match manufacturer's
specifications. 
Check that the output pressure regulator installed collate-
rally to the plant conforms to the specifications laid down
in paragraph "Checking input pressure" (see data plate or
measure the pressure). 

Checking the primary air 

The primary air in the open burners can be adjusted. 
Air volume flow is correct when there is sufficient protec-
tion against the flame rising when the burner is cold or li-
ght-back when it is hot. 

Checking the functions 

- Start the appliance in accordance with the instructions; 
- Check the gas tubes for leaks;
- Check that the flame on the main burner lights properly

and is correctly formed, even on low; 

- Draw up a servicing and maintenance contract. 

Note for the installer 

- Explain and demonstrate to the user how the machine

works according to the instructions, and hand him this
manual. 

- Remind the user that any structural alterations to the

room housing the appliance may affect the combustion
air supply. Once the alterations have been completed,
the appliance and its functions should be thoroughly
checked. 

Running the appliance on other types
of gas 

When changing to another type of gas, e.g. from natural to
LP, or to another gas group, consult the “TECHNICAL DA-
TA” table to make sure you use the appropriate nozzlzes
for the main burner. 
The nozzles for the cooking top burners for different types
of gas, marked in 100ths of mm, are in a case supplied
with the appliance. 
When the appliance has been transformed or adapted, re-
check its functions as described in paragraph "Checking
the functions". 

Replacing the gas ring nozzles (Fig. 2) 

To change nozzle (C), remove the knobs and loosen the
control panel fixing screws. 
Remove the control panel, disconnect the ignition lead
and unscrew the nozzle from the nozzle holder with a
spanner. 
Replace with a new nozzle (see “TECHNICAL DATA” ta-
ble); if necessary, to facilitate this operation push the air
adjustment sleeve upwards loosening screw (G).
After fitting the nozzle, reset primary air distance “A” (see
“TECHNICAL DATA” table). 

Replacing the oven nozzle (Fig. 3) 

To gain access to the oven burner, remove the oven floor
(from inside the oven cavity).
Remove screws D (Fig. 3) and remove the burner by pul-
ling it forwards; using the special spanner, unscrew the
injector C (Fig. 3) and replace it with the correct one for
the type of gas. 
Replace the burner, following the above procedure in the
reverse order.

Adjusting the primary air

Light the burner and inspect the flame;  if necessary, adju-
st the air as follows:
Loosen screw D (Fig. 3), move the burner in the direction
necessary to obtain a steady, even flame.

Replacement of nozzle of gas oven
GN 1/1 ventilated (Fig. 2B)

After opening the door, remove the grill, the grill supports
and the stainless steel bottom, then unscrew the protec-
tion form the nozzle zone.  
Remove the air adjustment by unscrewing screw (2). The
nozzle is now accessible. Replace it with one that is suita-
ble for the type of gas to be used. See the table "TECHNI-
CAL DATA".  After replacement, reassemble everything
and perform air adjustment (see the table "TECHNICAL
DATA").

Adjusting the low flame of the gas
rings (Fig. 2) 

Referring to the “TECHNICAL DATA” table, set the low fla-
me screw (D) as follows: 

- if the appliance is to run on LP gas, tighten the low fla-

me screw as far as it will go; 

- if the appliance is to run on natural gas, turn the low fla-

me screw while simultaneously adjusting the primary air:

read off the setting in It/min which corresponds to

the heat value (calculated by the “Volumetric Method”)
in the Gas Flow Setting Table (2);

start the appliance up according to the instructions;

after allowing the appliance to run for 45 minutes,

turn the knob to low and set minimum by turning screw
(20) (to the right = gas flow decreases; to the left =
gas flow increases).

Adjust the gas flow. 

Adjusting the low flame of the oven
(Fig. 3)

Loosen screw H (Fig. 3) by two or three turns after having
removed the knob and the control panel cover.  Light the
burner and keep it lit for at least 10 minutes with the knob
in the MAX 

position, then put the knob to Min

and

tighten screw H until a reduced but steady, even flame is
obtained (the flame must warm the thermocouple even
on low).

Содержание ABA2001

Страница 1: ...Instructions for installation use and maintenance GAS COOKER 024_03 04 2006 ABA2001 ABA2003...

Страница 2: ...ozzles 8 Replacing the oven nozzle 8 Adjusting the primary air 8 Replacing the nozzle of gas oven GN 1 1 8 Adjusting the low flame of the gas rings 8 Adjusting the low flame of the oven 8 Maintenance...

Страница 3: ...75 655 1 G 130 125 125 55 40 55 55 40 55 800 400 200 200 655 G 35 2 G 13 5 1 260 215 180 C B C B A 37 5 37 5 725 465 140 220 50 875 655 1 G 130 125 125 55 40 55 55 40 55 T A 37 5 37 5 1125 465 140 220...

Страница 4: ...P mbar 30 30 II2H3 P mbar 28 37 20 I3B P P mbar 30 30 I3 P mbar 28 37 SE FI DK CZ SK SI IT CH PT ES IE GB GR NL DE FR BE AT CH LU EE LV LT EE LV LT NO MT CY IS HU CY MOD MOD ART N N Qn kW m3 h MADE I...

Страница 5: ...3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 Electrical data Electric oven power Voltage No of cables per section Hour consumption G20 m3 h G25 m3 h G30 G31 kg h 8 1 B 70 5 2 5 0 7 0 265 0 19...

Страница 6: ...the sides and back should be allowed If this is impossible take proper steps to ensure the instal lation is safe such as fitting tiles or heat reflecting material to the walls Before connecting up th...

Страница 7: ...ocket and connect it to the tube on the gauge after measuring the screw should be retightened absolutely airtight F Checking power rating using the volumetric method Using a gas meter and a chronomete...

Страница 8: ...justment sleeve upwards loosening screw G After fitting the nozzle reset primary air distance A see TECHNICAL DATA table Replacing the oven nozzle Fig 3 To gain access to the oven burner remove the ov...

Страница 9: ...nsert the new part After replacing the parts fit the control panel back into place Oven ignition plug A Fig 3 Remove the floor unscrew the lock nut and the cable in sert the new ignition plug making s...

Страница 10: ...024 03 Gas cooker 10 G B C F D E 2...

Страница 11: ...024 03 Gas cooker 11 R B A D C L G H 195 180 16 0 140 120 100 3 18 6 14 16 15 3 9 19 2 2B I 2 3 4 5 6 7 4 6 1 3 2 0 2 3 4 5 6 7 M A X 5 3A...

Страница 12: ...ressed down for about 10 Switching on the oven light Press the switch on the oven control panel only CC80G Lighting ventilated gas oven GN 1 1 Fig 3B Turn on the switch located up the line from the un...

Страница 13: ...e of iron Do not clean the appliance with emery or sandpaper If absolutely necessary you may use powdered pumice stone If the appliance is extremely dirty use a synthetic sponge such as Scotchbrite Af...

Страница 14: ...or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do...

Страница 15: ...NUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED THIS DOCUMENTATION IS ONL...

Отзывы: