Hot-Runner Temperature Controller
with METICOM TM10 module
User Guide
Ver. 1.01
Страница 1: ...Hot Runner Temperature Controller with METICOM TM10 module User Guide Ver 1 01...
Страница 2: ...ic equipment you must observe standard safety procedures to protect both yourself and the equipment Cautions Service and installation of this equipment should only be performed by qualified service pe...
Страница 3: ...nel of the mainframe This diagram indicates the input voltage configuration that was prewired at the factory Make sure it matches what you ordered 3 INSTALLATION 1 You are installing a piece of electr...
Страница 4: ...Page 4 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 4 BACK PANEL WIRING...
Страница 5: ...Page 5 Copyright Mastip Technology Limited Information subject to alteration V3 51a www mastip com Temperature Controller METICOM TM10 Module 5 TYPICAL SYSTEM WIRING DIAGRAM...
Страница 6: ...teration V3 51a www mastip com Temperature Controller METICOM TM10 Module 6 Default CONNECTOR WIRING can be customized Combination Power Thermocouple Connector 16 or 24 Pin Separate Power Thermocouple...
Страница 7: ...le is set to be automatic closed loop control mode before shipping The temperature control module will show the code of the expected thermocouple type please check it and adjust the related setting ac...
Страница 8: ...m Thermocouple reverse alarm Temperature high alarm Temperature low alarm Heater fault alarm Heating invalid alarm High alarm of ambient temperature High limit of load current High limit of output per...
Страница 9: ...trol is an open loop system and requires no thermocouple feedback signal It can be used when thermocouple is failed or without thermocouple in system The controller s PV displays present temperature v...
Страница 10: ...difying the setting until new alarm happens 3 ALL low deviation alarm value When present value SV ALL the buzzer is beeping No alarm when power on or after modifying the setting until new alarm happen...
Страница 11: ...be changed quickly by press DISP key 9s 2 C F temperature unit 0 1 3 Sot soft start heater dehumidify function 0 Off 1 10 On soft start time Sot 80s Notes The rest of soft start time reduced to one th...
Страница 12: ...0 the controller will auto start standby mode until the operator end it by pressing MODE key 0 Off filtering value Std s number in the tens place ones place Used to reduce the influence of interferen...
Страница 13: ...ng make Snb 0 if the connection is right E r H Yes Thermocouple open Check the sensor or switch to manual control mode E r L Yes Thermocouple inverse H E A HEA No Heater fault Check the heater t r S Y...