Mastervolt 55006010 Скачать руководство пользователя страница 8

INSTALLATION

8

 

4.4 INPUTS 

See figure 2 and figure 3 to connect the AC power 

sources.  

Wire  

INPUT 1 

INPUT 2 

L (phase) 

1

R1

N (neutral) 

3

R3

PE (ground) 

Figure 3:  

Connections to the AC sources

  

4.5 OUTPUTS 

Connect the load to the terminals as indicated in figure 2 

and figure 4.  

Wire  

OUTPUT 

L (phase) 

2 + R2 

N (neutral) 

R4 + 4 

PE (ground) 

Figure 4:  

Connections to the AC output

 

4.6 SETTINGS 

Under normal circumstances adjustment of the 

Masterswitch 0

 is not recommended: after installation the 

Masterswitch 0

 is immediately ready for use. However 

specific circumstances may require adjustment of the 

switch-on delay time of INPUT 1.  

See figure 2. Use a small flat blade screw driver to adjust 

the delay time  

4.7 COMMISSIONING 

AFTER 

INSTALLATION 

Follow the steps described below to switch on the 

Masterswitch 0

.  

1.

Tighten all cable glands to ensure the pull relief

2.

Check all wiring and connections.

3.

Close the cabinet.

4.

Switch on the AC power sources.

4.8 DECOMMISSIONING 

If it is necessary to put the 

Masterswitch 0

 out of 

operation, follow the instructions in order of succession as 

described below: 

1.

Switch off all loads

2.

Switch off the AC power sources. These power

sources should be secured against unexpected and

unintended switching on.

3.

Open the casing of the 

Masterswitch 0

4.

Check with a suitable voltage meter whether the

inputs of the 

Masterswitch 0

 are voltage free.

5.

Disconnect all the wiring

Now the 

Masterswitch 0

 can be demounted in a safe way. 

4.9 TRANSPORTATION 

Always use the original packing for transportation. Contact 

your local Mastervolt Service Centre for further details if 

you want to return the apparatus for repair. 

4.10 RE-INSTALLATION 

To reinstall the 

Masterswitch 0

, follow the instructions as 

described in chapter 4 

Содержание 55006010

Страница 1: ...INSTALLATION AND USERS MANUAL MASTERSWITCH 0 Automatic AC transfer switch...

Страница 2: ...ended purpose 4 2 3 Organizational measures 4 2 4 Warning of special dangers 4 3 HOW IT WORKS 5 3 1 Source priority 5 3 2 INPUT 1 generator or shore input 5 3 3 INPUT 2 inverter input 5 4 INSTALLATION...

Страница 3: ...ICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place which is not in accordance with the guidelines inst...

Страница 4: ...er use the Masterswitch 0 in situations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Masterswitch 0 other than mentioned in point 2 is not considered t...

Страница 5: ...mately 10 seconds The 10 seconds delay time provides an easy start up for the generator In normal situations the generator is stabilized after app 3 sec To make sure no voltage and frequency variation...

Страница 6: ...n mm AWG 0 16 Amp 2 5 mm AWG 13 16 32 Amp 4 mm AWG 11 32 48 Amp 6 mm AWG 9 48 80 Amp 10 mm AWG 7 WARNING Use cable with the right cable diameter Under sized cables and or loose connections can cause d...

Страница 7: ...re 2 Installation of the Masterswitch 0 Masterswitch 0 7kW 117V 60A Masterswitch 0 9kW 117V 80A Masterswitch 0 5kW 230V 20A Masterswitch 0 10kW 230V 40A Masterswitch 0 3 5kW 117V 32A Delay time INPUT1...

Страница 8: ...h on the Masterswitch 0 1 Tighten all cable glands to ensure the pull relief 2 Check all wiring and connections 3 Close the cabinet 4 Switch on the AC power sources 4 8 DECOMMISSIONING If it is necess...

Страница 9: ...ely 10 sec adjustable see chapter 4 6 Dimensions H x W x D see also chapter 6 200 x 123 x 111 5 mm 7 9 x 4 8 x 4 4 inch 200 x 123 x 111 5 mm 7 9 x 4 8 x 4 4 inch Approximate weight 1 2 kg 2 6 Lbs 5 1...

Страница 10: ...DRAWINGS All dimensions are in millimeters Figure 5 dimensions of the Masterswitch 0 Masterswitch 0 5kW 230V 20A Masterswitch 0 10kW 230V 40A Masterswitch 0 3 5kW 117V 32A Masterswitch 0 7kW 117V 60A...

Страница 11: ...A Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonized standards have been applied Generic emission standard EN 50081 1 19...