EC DECLARATION OF CONFIRMITY 

7  EC DECLARATION OF CONFIRMITY 

Herewith declares that: 

Product:  

55006010 

Masterswitch 0 – 5kW 230V/20A 

55006015 

Masterswitch 0 – 10kW 230V/40A 

55106000 

Masterswitch 0 – 3.5kW 117V/32A 

55106100 

Masterswitch 0 – 7kW 117V/60A 

55106200 

Masterswitch 0 – 9kW 117V/80A 

Is in conformity with the provision of the EC, EMC directive 89/336/EEC and amendments 92/31/EEC, 93/68/EEC 

The following harmonized standards have been applied: 

Generic emission standard EN 50081-1:1992, 

Generic immunity standard EN 50082-1:1997, 

And the safety directive 73/23/EEC and amendment 93/68/EEC, with the following standard: 

Low voltage standard EN 60950:2000, 

Amsterdam, 

R.J. ter Heide, 

General Manager MASTERVOLT  

Learn more about marine electronics and navigation we have.

Содержание 55006010

Страница 1: ...INSTALLATION AND USERS MANUAL MASTERSWITCH 0 Automatic AC transfer switch...

Страница 2: ...ended purpose 4 2 3 Organizational measures 4 2 4 Warning of special dangers 4 3 HOW IT WORKS 5 3 1 Source priority 5 3 2 INPUT 1 generator or shore input 5 3 3 INPUT 2 inverter input 5 4 INSTALLATION...

Страница 3: ...ICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place which is not in accordance with the guidelines inst...

Страница 4: ...er use the Masterswitch 0 in situations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Masterswitch 0 other than mentioned in point 2 is not considered t...

Страница 5: ...mately 10 seconds The 10 seconds delay time provides an easy start up for the generator In normal situations the generator is stabilized after app 3 sec To make sure no voltage and frequency variation...

Страница 6: ...n mm AWG 0 16 Amp 2 5 mm AWG 13 16 32 Amp 4 mm AWG 11 32 48 Amp 6 mm AWG 9 48 80 Amp 10 mm AWG 7 WARNING Use cable with the right cable diameter Under sized cables and or loose connections can cause d...

Страница 7: ...re 2 Installation of the Masterswitch 0 Masterswitch 0 7kW 117V 60A Masterswitch 0 9kW 117V 80A Masterswitch 0 5kW 230V 20A Masterswitch 0 10kW 230V 40A Masterswitch 0 3 5kW 117V 32A Delay time INPUT1...

Страница 8: ...h on the Masterswitch 0 1 Tighten all cable glands to ensure the pull relief 2 Check all wiring and connections 3 Close the cabinet 4 Switch on the AC power sources 4 8 DECOMMISSIONING If it is necess...

Страница 9: ...ely 10 sec adjustable see chapter 4 6 Dimensions H x W x D see also chapter 6 200 x 123 x 111 5 mm 7 9 x 4 8 x 4 4 inch 200 x 123 x 111 5 mm 7 9 x 4 8 x 4 4 inch Approximate weight 1 2 kg 2 6 Lbs 5 1...

Страница 10: ...DRAWINGS All dimensions are in millimeters Figure 5 dimensions of the Masterswitch 0 Masterswitch 0 5kW 230V 20A Masterswitch 0 10kW 230V 40A Masterswitch 0 3 5kW 117V 32A Masterswitch 0 7kW 117V 60A...

Страница 11: ...A Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonized standards have been applied Generic emission standard EN 50081 1 19...