21
22
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8
PROBLEM
POSSIBLE CAUSES
SOLUTIONS
The
regulator does
not regulate
the pressure.
The regulator or its internal parts
are dirty or damaged.
Replace the regulator.
The pressure
is low or there
is not enough
air.
There is a leak at one of the
fittings.
Check the fittings with soapy water. Tighten or
reseal leaking fittings (apply plumber's tape on
threads). Do not overtighten.
The tank drain valve is open.
Close the drain valve.
The air intake is restricted.
Clean or replace the air filter element.
Prolonged excessive use of air.
Decrease the amount of air used.
There is a hole in the air hose.
Check the air hose and replace it if necessary.
The tank leaks.
Replace the tank Immediately. Do not attempt
to repair it.
The valve is leaking.
Check for worn parts and replace them if
necessary.
There is
moisture in the
discharge air.
There is condensation in the air
tank caused by a high level of
atmospheric humidity or because
the air compressor has not been
running long enough.
Drain the air tank after each use. Drain the air
tank more often in humid weather and use an
air line filter.
The
compressor
overheats.
The ventilation is inadequate.
Relocate the compressor to an area with cool,
dry and well-circulated air.
Cooling surfaces are dirty.
Clean all cooling surfaces on the pump and the
motor thoroughly.
The valve is leaking.
Replace worn parts and reassemble using new
Teflon tape.
TR
OU
BLE
SH
OO
TIN
G
EX
PL
OD
ED
VI
EW
SCAN
&
LEARN
NUMÉRISEZ
ET
APPRENEZ
Shop smarter on your smartphone
Get the free app at/Obtenez l’application gratuite sur :
canadiantire.ca/mobileapp
Balayez le code à barres pour obtenir plus de renseignements
sur les compresseurs et les outils pneumatiques.
Facilitez vos achats avec
votre téléphone intelligent
Scan barcode for more information on compressors and air tools.
058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd 21-22
7/4/12 11:26 AM