background image

9

10

AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8

AIR COMPRESSOR 11-GALLON (41.6 L) - 058-8386-8

J.  AIR TANK:

 The tank is where the compressed air is stored.

K.  POWER CORD:

 This compressor should be 

used on a nominal 120 V grounded circuit. 
Use a power cord that is equipped with a 
grounding plug. Verify that the compressor 
is plugged into an outlet that has the same 
configuration as the plug. Do not use an 
adapter with this compressor.

Plug

Grounding pin

Grounded 
outlets

Before you start

This Mastercraft® Air Compressor is ideal for a wide-range of applications from, fastening to greasing 
and engine cleaning. The 11-gallon (41.6 L) design provides optimum pressure. It features oil-free use 
and a 3 HP universal motor for powerful, quiet operation.

The procedures described in this manual are solely for this 11-gallon (41.6 L) air compressor at a 
maximum of P=135 PSI.  The device has been designed / constructed for household use only.

 

WARNING!

 This air compressor is not designed for continuous operation or unlimited, 

commercial operations and may be used in dry areas only. This air compressor is intended 
to be used in maximum 30-minute intervals and should rest for 30 minutes before being 
used again.

 Do not exceed the maximum working time.

Compatible compressor & air tool - proper usage & operation

Always ensure the use of appropriately matched air tools with your Mastercraft® Air Compressor. Be 
sure that the air compressor being used can supply the appropriate volume, pressure and delivery rate 
of air to the tool(s) without running continuously. Using tools or combinations of tools that, together or 
separately, require more than the air compressor can deliver will void the air compressor guarantee/
warranty.

KE

PA

RT

LI

ST

IN

TE

ND

ED

 U

SE

058-8386-8-Mastercraft-11G-3HP-Air-Compressor-EN-08.indd   9-10

7/4/12   11:26 AM

Содержание 058-8386-8

Страница 1: ...re using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed on to a thi...

Страница 2: ...e motor might get damaged see Breaking in the pump page 14 STEP 4 Close the tank drain valve located on the bottom of the air tank TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY...

Страница 3: ...rd that may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR...

Страница 4: ...the power cord from damage and puncture Inspect them for weak or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do so may...

Страница 5: ...has not shut down the motor It will pop open automatically or it can be activated manually by pulling the ring on the valve E Air pressure regulator The regulator is used to adjust the pressure inside...

Страница 6: ...gallon 41 6 L air compressor at a maximum of P 135 PSI The device has been designed constructed for household use only WARNING This air compressor is not designed for continuous operation or unlimite...

Страница 7: ...r its intended use 3 Positioning of the air compressor a Position the air compressor near an electrical outlet b The compressor must be at least 12 31 cm from any wall or obstruction in a clean well v...

Страница 8: ...not provided to the compressor s air outlet H Breaking in the pump 1 Set the pressure switch C to the OFF position OFF 2 Open the tank drain valve I by turning it counter clockwise to permit the air...

Страница 9: ...he ON position The air receiver will fill to cut out pressure and then the compressor s motor will stop The compressor is now ready for use Before each start up 1 Set the pressure switch C to the OFF...

Страница 10: ...ing of condensation water NOTE Refer to To drain tank page 19 Daily Check the valve Pull activate the safety valve daily to ensure that it is operating properly and to clear the valve of any possible...

Страница 11: ...is in the OFF position Set the pressure switch to the ON position The extension cord is the wrong wire gauge or is too long Check Technical Specifications proper wire gauge and cord length The motor s...

Страница 12: ...re is moisture in the discharge air There is condensation in the air tank caused by a high level of atmospheric humidity or because the air compressor has not been running long enough Drain the air ta...

Страница 13: ...reof which is worn or broken or which has become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operation or maintenance as outlined in the applicable owner s...

Страница 14: ...al or exemplary damages arising in connection with the sale use or inability to use this product Notice to Consumer This warranty gives you specific legal rights and you may have other rights which ma...

Отзывы: