8
— Place your hob in the opening of the
support cabinet, carefully pulling the table
towards you.
— Reposition the burner heads, burner
covers and pan supports on the hob.
Connect your hob to the gas supply (See
“Gas Connection” chapter) and to the power
supply (See “Electrical Connection” chapter).
— If you wish, you can immobilise the hob
using the four mounting brackets delivered
with their screws
(Fig. 02)
to attach them to
the four corners of the housing. You must
use the holes provided for this purpose,
according to the diagram above
(Fig. 01)
.
— Stop screwing when the mounting bracket
starts to become deformed.
Do not use a screwdriver.
•
FITTING TIPS
EN
2 / INSTALLING YOUR APPLIANCE
Fig. 02
Mounting bracket
Screw
Mounting holes
A
Cabinet
•
ELECTRIC CONNECTION
Your hob must be connected to the 220-240 V~
single phase grid via a standardised CEI 60083
2-pole + ground electrical outlet plug or an all-
pole cut-off device, in compliance with the
current regulations.
The plug of the electrical outlet must be
accessible after installation.
Warning
The safety wire (green/yellow) is
connected to the ground terminal
of
the appliance and must be connected to the
ground terminal
of the installation The fuse
in your set-up must be 10 amperes. If the
power cable is damaged, it must be replaced
by a cable or a special kit available from the
manufacturer or its After-Sales Service
Department.
Tip
Using a gas cooking appliance results in
the generation of heat and humidity in the
location where it is installed. Make sure that
your kitchen is well-ventilated: keep natural
ventilation openings in your home clear or
install a mechanical ventilation device
(mechanical ventilation hood). Intensive,
prolonged use of the appliance may require
additional ventilation; you can, for example,
open a window or provide more effective
ventilation by increasing the power of the
mechanical ventilation system, if you have one.
(A minimum air flow of 2 m
3
/hr per kW of gas
power is required).
For example : 30 cm, 2 gas b
Total power: 1.5 + 3.1 = 4.6 kW
4.6 kW x 2 = 9.2 m
3
/hr minimum
flow.
C
ROSS
-
SECTION OF CABLE TO BE USED
H05V2V2F -T90 cable
Ref. After-sales
service: 77x9060
Cross-section of
conductors in mm
2
Fuse
220-240 V~ - 50 Hz
3 conductors
including
1 ground
1
10 A
A
Fig. 01
Underside view
of the housing
A