background image

 

 

   

 

 

 

CLKTCD12 

 

TIME CODE 

ANALOG CLOCK 

 

(STEPPER MOTOR MOVEMENT) 

 

USER MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Masterclock, Inc. 

Tel: 636-724-3666 Fax: 636-724-3776

 

2484 W Clay St,  St Charles  MO  63301

 

Masterclock, Inc  2006-2007 

 

          

     

Содержание CLKTCD12

Страница 1: ...CLKTCD12 TIME CODE ANALOG CLOCK STEPPER MOTOR MOVEMENT USER MANUAL Masterclock Inc Tel 636 724 3666 Fax 636 724 3776 2484 W Clay St St Charles MO 63301 Masterclock Inc 2006 2007...

Страница 2: ...to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Masterclock shall not be liable for errors contained here in or for incide...

Страница 3: ...mation 7 Mounting 8 Display Behavior 9 Configuration 9 Configuration via Switches 10 Default Configuration 13 Reset Factory Default Configuration 13 Configuration Software CLKTCD Set USB Port 16 Troub...

Страница 4: ...anders Council U S Army White Sands Missile Range The format is used by military government power industry and many other commercial and industrial applications The CLKTCD decodes IRIG B in both a 1kH...

Страница 5: ...d Hand with Sweep or Step optional run modes Self correcting after loss of power and or time code reference and DST changes Rapid hand correction using fast mode Status LED on clock face located at 6...

Страница 6: ...to utilize a time code source with UTC reference and configuring the offsetting for your time zone and DST in your local time display clock Daylight Saving Time An automatic daylight saving time summe...

Страница 7: ...of local time of day as in U S For the European Union Summertime period begins at 1 00 AM UTC and ends at 1 00 AM UTC European customers please carefully consult the section entitled Device Settings...

Страница 8: ...will move rapidly in either a clockwise or counter clockwise motion This is normal operation for the clock during the correction adjustment cycle Status LED The red LED on the CLKTCD12 clock face loc...

Страница 9: ...06 2007 Rev 1 2 0 May 07 http www masterclock com The DC version special order option is designed to operate on 24VDC nominal regulated or 18 28 VDC power supplies Please see the special order options...

Страница 10: ...the CLTCD12 clock If for any reason the clock hands become slightly out of alignment a calibration setting function has been provided Apply power Insert the power cord AC models will require an IEC p...

Страница 11: ...ating in either clockwise or counter clockwise direction during a correction cycle This may take up to 20 minutes depending upon the location of the hands at the start of the cycle Once the hands have...

Страница 12: ...allowing the unit to retain configuration settings even when power is off The CLKTCD12 may be configured by either DIP switches or via software control using the USB port and software configuration ut...

Страница 13: ...S1 1 S1 2 S1 3 S1 4 Time zone hour offset Hour offset S1 1 S1 2 S1 3 S1 4 0 hour offset OFF OFF OFF OFF default 1 hour offset ON OFF OFF OFF 2 hour offset OFF ON OFF OFF 3 hour offset ON ON OFF OFF 4...

Страница 14: ...tive ON Switch S1 7 S1 8 Daylight saving time adjustment See Daylight Saving Time Function S1 7 S1 8 DST adjustment disabled OFF OFF default US Canada DST enabled ON OFF US standard thru Fall 2006 US...

Страница 15: ...d for future use Function S2 3 Reserved OFF default Reserved ON Switch S2 4 This switch is currently undefined and reserved for future use Function S2 4 Reserved OFF default Reserved ON Switch S2 5 Th...

Страница 16: ...tory Default Configuration In some situations it may be necessary to return the CLKTCD12 to its factory default configuration A RESET to factory configuration is accomplished by pressing button combin...

Страница 17: ...ooting section for additional information suggestions To adjust the hands Select the Set position for switch S2 8 the unit will enter the adjustment mode the hands of the analog clock will stop 1 Sele...

Страница 18: ...r of 12 tic mark mark minute second hands point to center of 12 tic mark 8 Change SW2 8 to Run mode OFF The new hand alignment settings will be stored in non volatile flash The clock hands will adjust...

Страница 19: ...USB drivers Once the clock is powered the Windows Plug and Play manager will detect a new USB device Masterclock USB device and request drivers Insert the driver software CD that was included with you...

Страница 20: ...UTC Time is the internal time reference derived from the incoming time code and treated as UTC This display update is not precise but is meant to give you a view of the clock display time for basic tr...

Страница 21: ...function by first selecting the Daylight Saving Time if appropriate for your application North American DST settings are quickly configured by entered by selecting the appropriate US Canada Standard...

Страница 22: ...ion and gain control circuit for the incoming SMPTE 30 25 24 fps longitudinal linear time code or for IRIG B 0 pulse width modulated or IRIG B 1 amplitude modulated time code As mentioned previously i...

Страница 23: ...code display of date and year information being displayed and interpreted as January 01 2000 for both date encoded and non date encoded types of incoming time code The time information will be decoded...

Страница 24: ...not present The time can either be set to the time of the PC or a manual time and date can be entered Note When the clock has access to a valid time code source information obtained via timecode will...

Страница 25: ...ing the clock hands only after the CLKTCD12 indicates that it is synchronized to time code and then only to a digital display or other reference that has also been locked preferably to the same time c...

Страница 26: ...CLKTCD12 User Manual 23 Masterclock Inc 2006 2007 Rev 1 2 0 May 07 http www masterclock com...

Страница 27: ...ion for acceptable signal level ranges 5 The time code being fed to the CLKTCD12 is not a recognized format Verify that your time code source is providing one of the time code formats that the CLKTCD1...

Страница 28: ...erence 3 Ensure that you are not using Drop Frame SMPTE time code Drop Frame time code is not supported Accurate time cannot be guaranteed with drop frame time code 4 The clock hands have been incorre...

Страница 29: ...e time code input caused by power loss configuration changes to time zone offset daylight saving time or entry into from daylight savings time will cause the clock to enter a correction cycle This cor...

Страница 30: ...ratio IRIG B 0 dc offset level shifted un modulated pulse width modulated TTL level Nominal Level 1 5 Vpp 0dB 600 Level Range 0 175 12 Vpp 15dBV to 20dBV Impedance 100 K Connector BNC female Single E...

Страница 31: ...ther loss of power or internal battery voltage Physical 12 5 31 8cm Round Black Metal Case with 12 Face 4 25 10 8cm high polycarbonate lens Weight 7 6 lbs 3 45kg Power Supply Component Characteristics...

Страница 32: ...lowing Safety standards EN60950 1 2001 Safety of Information Technology Equipment Waste Electrical and Electronic Equipment Directive WEEE 2002 95 EC The TCD time display models are considered WEEE Ca...

Страница 33: ...allation or maintenance by the customer customer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper...

Страница 34: ...e cloth Minimize Hairline Scratches Always store the clock face up in the protective plastic shipping bag until ready for installation and during transporting to the installation site Do not place the...

Страница 35: ...olvent will not penetrate sticker material apply heat hair dryer to soften the adhesive and promote removal GASOLINE SHOULD NEVER BE USED Job Site Precautions It is recommended the clock be removed fr...

Страница 36: ...d attach the power signal cables secure the clock to the bracket using the retaining screw Caution Do not route power or signal cables between the case and the wall along the exterior of the wall whic...

Страница 37: ...CLKTCD12 User Manual b Masterclock Inc 2006 2007 Rev 1 2 0 May 07 http www masterclock com...

Страница 38: ...CLKTCD12 User Manual c Masterclock Inc 2006 2007 Rev 1 2 0 May 07 http www masterclock com...

Страница 39: ...CLKTCD12 User Manual d Masterclock Inc 2006 2007 Rev 1 2 0 May 07 http www masterclock com...

Отзывы: