5
CHARCOAL
LP GAS CYLINDER, HOSE AND REGULATOR INSTALLATION
• Never leave HOT coals or ashes unattended.
• Charcoal should be kept red hot for at least 30 minutes prior to use.
• Do not cook before the charcoal has a coating of ash.
• Keep hands, hair, and face away from the burning charcoal. Be careful of loose hair and clothing during
operation as they could catch fire.
• Use protective gloves when handling this smoker or working with fire. Use protective gloves or long,
sturdy fireplace tools when adding wood or charcoal.
• Never use gasoline to light charcoal.
• Overfilling charcoal bowl can cause serious injury and damage the smoker.
• Never add additional lighter fluid once charcoal has ignited. Follow directions on lighter fluid container.
• Dispose of cold ashes by placing them in aluminum foil, soaking with water, and discarding in a non-
combustible container.
• WARNING! This barbecue will become very hot, do not move it during operation.
• DO NOT USE INDOORS!
• WARNING! Do not use spirit or petrol for lighting or re-lighting! Use only firelighters complying to EN 1860-3!
• WARNING! Keep children and pets away.
WARNINGS AND IMPORTANT SAFEGUARDS
• Never fill cylinder over 80% full or cylinder may release gas causing fire which may cause death or
serious injury.
• Place a dust cap on the cylinder valve outlet whenever the cylinder is not in use. Only install the type
of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
• Never use LP gas cylinder if there is evidence of dents, gouges, bulges, fire damage, erosion, leakage,
excessive rust, or other forms of visible external damage. This may be hazardous and cylinder should
be taken to a liquid propane supplier to be checked.
• Never attach/disconnect LP gas cylinder, move or alter gas fittings when smoker is in operation.
• This smoker is designed to work with propane gas only. Only use gas cylinders marked “propane” with
this smoker.
• This smoker will NOT operate with natural gas.
• Clean and inspect the hose before each use of the smoker. If there is evidence of abrasion, wear, cuts
or leaks DO NOT USE. The hose must be replaced prior to the smoker being put into operation. The hose
assembly supplied with smoker MUST be used. For replacement parts, if needed, contact Masterbuilt
Customer Service at 44 20 8036 3201 (UK) or 0031 4 7799920 (EU).
• The type of regulator used must comply with the relevent EN standard.
• Keep the fuel supply hose away from any heated surface(s).
• Keep the fuel supply hose away from smoker while in operation.
• Hose must be routed from beneath smoker, between left front and rear legs and then to LP gas cylinder.
Содержание MPS 230S
Страница 16: ...16 6 A 25 5 24 A Piezo Ignitor Ignition Wire Valve Orifice Venturi 3 X4 A 4 X4 A ASSEMBLY Venturi ...
Страница 17: ...17 1 29 G 20 6 B B 5 6 B X4 X2 G ASSEMBLY ...
Страница 19: ...19 F F 1 8 A 28 1 D 9 10 X1 A D X1 F X4 ASSEMBLY ...
Страница 20: ...20 H 2 13 2 C 2 7 C 26 7 11 H X1 12 X4 C ASSEMBLY ...
Страница 21: ...21 21 1 13 14 ASSEMBLY 21 12 ...
Страница 22: ...22 21 10 11 9 15 16 ASSEMBLY 23 29 ...
Страница 23: ...23 22 1 17 ASSEMBLY ...
Страница 26: ...26 ...
Страница 27: ...27 ...