background image

www.desatech.com

120942-01E

7

eLecTricaL SUPPLy

This  heater  requires  an  electrical  supply  to 
be furnished by the user. The electrical outlet 
should have the following ratings:

120 volts (+/- 10%), 60 Hertz, 15 Amps

Ground Fault Interrupter (GFI)

The heater uses the ground circuit to prove the 

flame by sending a low voltage (40 mV DC) 

signal back to the DSI control. If the ground 
supply is not correctly wired or is missing, the 
heater will not work.

ExTENSION CORDS

Extension cords used to connect the heater 
must  be  3  prong,  grounded  type  of  proper 
gauge. Extension cord requirements are as 
follows:

•  Up to 100 feet (30 m), use 16 AWG rated 

cord

•  101 to 200 feet (32 to 60 m), use 14 AWG 

rated cord.

OPERATION WITH PORTAbLE 
GENERATOR

 WARNING: before operating 

heater  or  any  appliance  from  a 

portable  generator,  verify  that 

generator has been properly con-

nected to earth ground. Improper 

grounding  or  failure  to  ground 

generator  can  result  in  electro-

cution  if  a  ground  fault  occurs. 

Refer to owner’s manual supplied 

by  generator  manufacturer  for 

proper grounding procedures.

The operating voltage range of the heater is 
108  to  132  Volts  (120  Volts  +/-  10%).  Prior 
to plugging heater into generator the output 

voltage  should  be  verified  (if  generator  is 

equipped with the automatic idle feature, the 
output voltage should be measured with the 
generator running at full speed). If the voltage 
does  not  measure  in  this  range  the  heater 
should not be plugged into the generator.

UnPacking

1.  Remove  all  packing  items  applied  to 

heater for shipment. Keep plastic cover 
caps  (attached  to  inlet  connector  and 
hose/regulator assembly) for storage.

2.  Remove all items from carton.
3.  Check all items for shipping damage. If 

heater is damaged, promptly inform dealer 
where you bought heater.

Содержание TENTEvent125 TB116A

Страница 1: ...ath serious bodily injury and property loss or damage from hazards of fire explosion burn asphyxiation carbon monoxide poisoning and or electrical shock Onlypersonswhocanunderstandandfollowtheinstruc...

Страница 2: ...ce must be performed by a quali fied installer service agency or the gas supplier If you smell gas turn off gas supply at tank This is an unvented gas fired tent heater It uses air oxy gen from the te...

Страница 3: ...en Depletion Sensing ODS safety shutoff system designed to turn off the heater if not enough fresh air is available Do not tamper with oxygen depletion safety system If heater shuts off do not relight...

Страница 4: ...ior to operating the heater 1 Install and use heater with care Follow all local ordinances and codes In the absence of local ordinances and codes refer to the Standard for Storage and Handling of Liqu...

Страница 5: ...ing to fresh outside air 3 high x 14 long 42 inches2 11 Minimum heater clearances from com bust ble materials Outlet 8 ft 2 40 m Sides 1 ft 30 cm Top 3 ft 0 91 m Rear 1 ft 30 cm 12 Keep heater at leas...

Страница 6: ...as dealer will help you select the proper supply system The mini mum surrounding air temperature rating for each heater is 20 F 29 C Propane LP gas and propane tank s are to be furnished by the user U...

Страница 7: ...om a portable generator verify that generatorhasbeenproperlycon nectedtoearthground Improper grounding or failure to ground generator can result in electro cution if a ground fault occurs Refertoowner...

Страница 8: ...bustion chamber This air is heated and provides a stream of clean hot air The Ignition System The direct spark ignitor DSI sends voltage to the spark ignitor The spark ignitor ignites the fuel and air...

Страница 9: ...de panel from heater to make installing casters easier If so see Top and Side Panel Removal on page 14 Figure 4 shows side panel removed for clarity 3 Use a spacer to prop end of heater up so holes in...

Страница 10: ...lide one wheel and washer onto axle Insert cotter pin into end of axle See Figure 5 4 Repeat steps 2 and 3 for second wheel washer and cotter pin on other side of heater 3 Turn top over and carefully...

Страница 11: ...ly valve and open again slowly 5 Check all connections for leaks Correct all leaks Figure 7 Regulator With Vent Pointing Down Hose Regulator Vent pointing down Fuel Gas Connector Supply Valve Propane...

Страница 12: ...al codes when using this heater To Start Heater 1 Follow all installation ventilation and safety information 2 Connect regulator hose assembly to gas supply 3 Check for leaks using a noncorrosive leak...

Страница 13: ...with a damp cloth Use household clean ers on difficult spots Slight odor may be present for a brief period following use of household cleaners 2 Inspect heater before each use Check connections for le...

Страница 14: ...op brackets to body panels Remove top and set aside see Figure 10 Brackets Located Underneath Figure 10 Removing Top and Side Panel Side Panel Top Bracket Screws Side Panel Screw 2 Remove 2 screws sec...

Страница 15: ...o gain access to screen Push screen up and over flange then slide out 2 Disconnect orange ignitor wire from ignit or Ignitor is attached to back of burner 3 Disconnect gas line at solenoid valve and a...

Страница 16: ...orange ignitor wire 3 Remove white wire connector 4 Remove 2 screws and nuts securing DSI control 5 Install new DSI control Reconnect wiring Replacing Gas Valve 1 Remove top and side panel see Top an...

Страница 17: ...kPa Maximum Tank Pressure Regulator Outlet Pressure 11 wc Electric Input 120 V 60 Hz Amperage Start 7 Run 3 5 Load 10 amps on receptacle Hot Air Output Approx 1000 CFM 28 3 m3 min Motor 1 100 RPM 1 4...

Страница 18: ...age 16 D Replace spark trans former See Replacing DSI Control page 16 3 Clean tubing POSSIBLE CAUSE 1 No electrical power to heater 2 Thermostat set too low 3 Ambient temperature is too high Thermosta...

Страница 19: ...upply cylinder size i e 100 lb POSSIBLE CAUSE 1 Propane supply may be inadequate 2 High surrounding air tem perature causing thermal limit device to shut down heater 3 Restricted air flow 4 Damaged fa...

Страница 20: ...c Solenoid Valve V lvula de solenoide lectrovanne DSI encendedor de chispa directa AED Black Negro Noir Black Negro Noir Black Negro Noir Black Negro Noir Black Negro Noir Orange Naranja Black Negro N...

Страница 21: ...Verify proper operation after servicing 1 Interruptor 1 ciclo autom tico Interrupteur 1 en cycle 2 Interruptor 2 continuo Interrupteur 2 en continu 3 Bloque de terminales Bornier 4 Interruptor de VCA...

Страница 22: ...www desatech com 120942 01E 22 Parts Cabinet Models TB116A TB117A and TB118A 16 17 14 15 7 2 6 5 9 13 19 18 20 21 8 4 3 11 1 12 14 15 10 10 10 10...

Страница 23: ...Base 1 17 120433 01 Front Panel White 1 120433 02 Front Panel Tan 1 18 120201 02 Caster 2 19 M16801 14 Plated Axle 1 20 113125 01 Wheel 2 21 100000 01 Cotter Pin 2 PARTS AVAILABLE NOT SHOWN Decals Av...

Страница 24: ...www desatech com 120942 01E 24 Parts Models TB116A TB117A and TB118A 17 21 11 10 16 13 12 14 9 8 7 22 2 4 3 19 1 18 20 5 15 6...

Страница 25: ...e 1 12 103934 01 Ignitor 1 13 119884 01 Ignitor Bracket 1 14 098249 01 ODS Nut 2 15 118254 01 Burner 1 16 M50104 02 Shorty Bushing 2 17 120095 01 Pressure Switch Assembly 1 18 120276 01 Duplex Cover 1...

Страница 26: ...an t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heater was m...

Страница 27: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 28: ...al codes and instructions furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by...

Отзывы: