DESCRIPTION

Warning: Only the burners which are chosen and sup-
plied by the manufacturer can be used. If another type 
of burner is used the heater no longer complies with CE 
regulations.

GREEN

 space heaters have been designed for use in small 

to medium-sized rooms and buildings where a fi xed or mobile 
heating system is required.
Heat is produced by combustion and the heat from the smoke 
is transmitted to the fresh air through the metal walls of the 
combustion chamber and the heat exchanger. The combustion 
chamber is of the type where smoke circulates twice.
The air and smoke pass through separated ducts, both of which 
are welded and sealed. When, after combustion, the waste ga-
ses have cooled, they are expelled through a duct which must 
be connected to a chimney or chimney fl ue. The chimney or 
chimney fl ue must be big enough to guarantee that the smoke 
is expelled effi ciently.
The air which is used in combustion is aspirated directly from the 
room or building which is being heated. It is therefore of utmost 
importance that the room or building be properly ventilated so 
that enough fresh air is circulating at all times.

GREEN

 heaters can operate with burners that are fuelled by 

heating oil, methane (G20) or L.P.G. (butane G3O and propane 
G31) of the ON-OFF type.
There are three safety devices which are activated in case of 
serious malfunction. The Burner Control Device, which is moun-
ted on the burner and has a restart button, automatically stops 
the burner if the fl ame goes out. The Overhrat Thermostat, L2, 
of the manuel restart type, is activated if the temperature of the 
combustion chamber rises above the set maximum limit; the 
warning light (9) lights up and the heater stops working. The 
Thermal Relay, RM, is activated if the fan motor starts to use 
more electrical current than the maximum permitted limit; the 
warning light (10) lights up and the heater stops working.
If any of these safety devices are activated you should check 
carefully what the problem actually is before pressing the restart 
button and starting  the heater off again (“OBSERVED FAULTS, 
CAUSES AND REMEDIES”). Overheat safety thermostat, L1, 
shuts down the heater if air fl ow is not suffi cient to cool off com-
bustion chamber: the heater will restart automatically as soon as 
the heater has cooled down enough (the lamp(9) lights up and 
then it cuts down).

GENERAL ADVICES

The space heater must be installed, set up and used in accor-
dancewith existing laws.
Here are a few general guidelines which should be followed:
• Follow the instructions in this booklet very carefully;
•  Don’t install the heater in places where there may be a risk of 

fi re or explosion;

•  Infl ammable material should be kept at a safe distance from 

the heater (Minimum 3 meters);

• All fi re prevention regulations must be adhered to;
•  The room or building which is being heated must be suffi ciently 

ventilated so that the heater has enough air to function pro-
perly;

•  The heater must be near a chimney or chimney fl ue and a sui-

table electric switchboard;

• Don’t let animals or children near the heater;

•  After use make sure  the disconnecting switch is off.
When using any type of space heater it is obligatory:
•  not to exceed the maximum level of heat output of the furnace 

(“TECHNICAL SPECIFICATION TABLE”);

•  to make sure that there is adequate air circulation and air sup-

plyto the heater and that nothing is obstructing the aspiration 
and expulsion of air; movement of air may be obstructed in 
various ways including placing covers or other objects on the 
heater or positioning the heater too near a wall or other large 
object. If the airfl ow is not adequate, the combustion chamber 
will over heat and the overheat safety thermostat L1 will turn 
the burner off and on continnously (“OBSERVED FAULTS, 
CAUSES AND REMEDIES”).

INSTALLATION

Warning: The following operations must be carried out by 
qualifi ed personnel only.

ELECTRICAL CONNECTIONS AND SETTINGS

Warning: The mains supply to the heater must be earthed 
and have a magneto-thermal switch with differential.
The power cord must be connected to a switch board 
which has a disconnecting switch.

Every space heater is supplied along with the safety and control 
devices which are indispensable to the correct functioning of the 
unit.The electric switchboard, burner, the fan thermostat, over 
heat safety thermostat and the overheat thermostat with manual 
restart have already been connected.
The following operations must now be carried out:
•  Plug in the power cord having read the adhesive label whi-

ch details electricity supply characteristics (Table 1). Table 2 
shows the adhesive label on units which have three-phase 
supply;

Model

M - M/C

Model

T - T/C

Number of phases

1

3

Tension

230

230/400

Frequency

50

50

•  The burner must be connected to the fuel supply (“Burner In-

struction Manual”);

•  Connect the burner to the electricity supply with the burner 

plug;

•  Connect accessories such as the room thermostat or clock to 

the unit’s electric switchboard: electric wire must be connected 
by means of the cable fastener (8) to the terminals (6) and (7).

Having completed all these operations check carefully that all 
electrical connections correspond to the wiring diagram. When 
the heateris fi rst turned on you must check that the fan does not 
use more current than the maximum permitted limit. Finally, to 

HOT AIR GENERATOR

7

GB

Tab. 1

[V]

[Hz]

230V - 3~ - 50Hz

❏ 

400V - 3~ - 50Hz

Tab. 2

Содержание GREEN 115

Страница 1: ...enance manual Bedienungsanweisung Manual del proprietario Manuel de L utilisateur IT Generatore d aria Calda GB Hot air generator DE Warmlufterhitzer ES Generadores de aire caliente FR Generateurs d a...

Страница 2: ...seguridad Lampe temoin securite de surchauffe 4 Presa per bruciatore Burner plug Sicherungschalter f r bren ner Enchufe para quemador 10 Spia blocco ventilatore Fan stop control lamp Ventilator aus ko...

Страница 3: ...the heater in places where there may be a risk of fire or explosion Inflammable material should be kept at a safe distance from the heater Minimum 3 meters All fire prevention regulations must be adhe...

Страница 4: ...material which is resistant to high temperatures and which ensures that the tube remains airtight CONNECTION TO FUEL SUPPLY AND CHANGING FROM ONE TYPE OFGAS TO ANOTHER To connect the burner to the fu...

Страница 5: ...en remove the smoke box panel 2 and remove baffle plates 7 To get at the combustion chamber 4 remove the burner 5 CLEANING THE FAN Remove any dirt or extraneous material from the mesh of the aspiratio...

Страница 6: ...sive 1 Heater with helicoidal ventilator remove even tualdebris preventing free flow of air on intake and outlet Check length of air ducts reduce if excessive 1 Heater with centrifugal ventilator chec...

Страница 7: ...IONE QUADRO CONTROL LAMP KONTROL LAMPE TESTIGO BLOQUEO VENTILADOR LAMPE TE MOIN MISE SOUS TENSION FB FUSIBILE BRUCIATORE BURNER FUSE SICHERUNG F R BENNER FUSIBLE QUEMADOR FUSIBLE BRU LEUR SB SPIA BLOC...