►1.13. Make sure the polarities are
respected when connecting to the
mains. We recommend using a suita-
ble residual current device (see name-
plate).
►1.14. The cooler can withstand a max
-
imum water inlet pressure of 3 Bar.
If the pressure of the water supply is
higher, a pressure reducer must be in-
stalled.
►1.15. Only fill the cooler tank only with
clean water.
►1.16. We recommend using horizontal
coverage to protect from weathering,
in order to preserve the cooler over
time.
►1.17. It is forbidden to alter, tamper
with or adjust the cooler and the elec-
tricity or water supply after installa-
tion, if it is not carried out by qualified
personnel.
►1.18. Do not obstruct, even partially,
the air vents of the cooler, in order to
prevent a hazard.
►1.19. In order to prevent serious dam
-
age, do not let dust, dirt or other mate-
rials come into contact with the cool-
er.
►1.20. We recommend using the cooler
with ambient temperatures between
18°C and 45°C and with water temper-
ature below 45°C.
►1.21. In order to prevent serious
breakdowns, when the temperatures
drop to about <2°C, completely empty
the tank and the pipes that supply wa-
ter to the cooler.
►1.22. Disconnect the power supply
when you handle or service the cooler
(use personal protective equipment in
order to prevent any hazards).
►1.23. If the power supply cable is dam
-
aged, it must be replaced by a techni-
cal support centre to prevent any risk.
►1.24. Protect the power cable from po
-
tential damage caused by the move-
ment of vehicles, pedestrians, weath-
ering and heat sources.
►1.25. If the cooler malfunctions, con
-
tact the technical support centre.
►1.26. Unplug the cooler from the pow
-
er supply, when it is not used for a
medium to long term period.
►1.27. The water used to fill the cooler
tank must come from an aqueduct. If
it is not possible to draw from an aq-
ueduct, the water introduced must be
subjected to a sanitation treatment,
according to European Directive
98/83/EC.
-We recommend using water with a
hardness of less than 15°f.
-The cooler tank must be emptied and
sanitised periodically depending on
the use.
-The cooling pad surfaces must be
periodically inspected and sanitised
depending on the use.
-For sanitation operations, biocidal
products that comply with European
regulation no. 582/2012 must be used.
►►►2. UNPACKING
IMPORTANT: IT IS STRICTLY FORBID-
DEN TO STACK TWO OR MORE COOL-
ERS.
►
2.1. Remove all packaging material
used to pack and deliver the cooler and
dispose of it in compliance with current
standards.
►
2.2. Remove all items from the packag-
ing.
►
2.3. Check for any damage incurred dur-
ing transport. If the cooler appears dam-
aged, immediately inform the dealer from
whom it was purchased.
►►►3. ASSEMBLY AND INSTAL
-
LATION (ONLY FOR QUALIFIED
PERSONNEL)
NOTE: TO ACCESS THE INTERNAL
PARTS OF THE COOLER, REMOVE THE
SCREWS AND EVAPORATION PANELS,