itself; 

not all the functions of the radio remote control are listed in this manual.

 

 

T

HE TRANSMITTER IS 

NOT

 FACTORY

-

PROGRAMMED

First  follow  the  radio  remote  control  instructions  and  then  those  provided 
below concerning the specific operation of the station. 

The station can accept up to 6 PIK radio remote controls. The same functions only with the 
PIK radio remote control with MASTER proprietary code (rolling code). 

Save procedure: 

-  Equip yourself with the radio remote control, checking beforehand that it is working, 

has charged batteries and is in good condition. 

-  Select the “Add” item in the menu. 
-  Press the “OK” button of the control unit. 
-  The message “Push” will appear on the display. 
-  On the PIK radio remote control 

(see the instructions provided with the radio remote 

control)

, select any channel between CH1 and CH6 and press any one of the 

/

 

ARROW or STOP buttons on the PIK for about 1 second. 

-  The “OK” message will appear on the display indicating that the save process was 

successful. 

-  The  radio  remote  control  is  now  saved  and  the  motors  are  controlled  by  the 

respective channels. (CH1=motor 1; CH2=motor 2….. CH6=motor 6) 
End 

Repeat the procedure for any other radio remote controls. 

 

Advanced procedure: associate desired channels or free a channel (“chc” menu). 

-  Select the “CHC” item in the menu of the station. 
-  Press the “OK” button of the control unit. 
-  The message “Push” will appear on the display. 
-  Select the desired channel on the PIK radio remote control and press any one of 

the 

/

 ARROW or STOP buttons for about 1 second. 

-  The list of motors from MOT1 to MOT6 and NULL will appear on the display. 

If you want to “free” a certain channel of the PIK (e.g., make it usable for other 
applications), select “NULL”. 

-  Use the +/- buttons of the control unit to scroll through the motors and select the 

motor you want to associate with the selected channel.  

-  Press OK. 
-  The association is complete. 

Repeat the procedure for any other radio remote controls or channels. 

6.4. 

Saving a radio remote control without access to the board 

Saving a new radio remote control remotely, i.e. without access to the electronic board of 
the station, can occur only if the user already has a previously saved radio remote control. 

Содержание 1120.30

Страница 1: ...Codice 4420078 Edition 1407 CONTROL BOARD 1120 30 1120 31 1120 32 1120 33 1120 34 1120 35 UNIT FOR VENTILATION WITH SEVERAL 24V DC MOTORS MANUAL FOR INSTALLATION AND USE English...

Страница 2: ...ing and indications for use provided with the product indicate presumed conformity to the directives issued by the European Community The manufacturer holds the technical archive with documentation pr...

Страница 3: ...rs P005 P104 P204 P304 P404 P504 P604 13 6 3 3 Wind sensor Parameters P103 P203 P303 P403 P503 P603 13 6 3 4 Cron Timer input on main board Parameters P105 P205 P305 P405 P505 P605 13 6 3 5 Sensor pri...

Страница 4: ...control have been designed and constructed exclusively to execute maneuvers for closing and or opening windows roll up blinds curtains and sunshades assisted by the aid of sensors for rain wind brigh...

Страница 5: ...cal systems The equipment has double electrical insulation and thus does not require an earth wire All devices connected to the station must be earthed by the installer unless equipped with double ins...

Страница 6: ...or adjustment operation The electrical power supply system must be designed and implemented in compliance with current standards Caution Check that the electric power supply used corresponds to that s...

Страница 7: ...TING INFORMATION 6 1 General instructions The control unit is composed of a main board which is set up for insertion of expansion module boards The expansion module boards differ depending on the cont...

Страница 8: ...ugh the programming menu or increase the value of the parameter within the menu The minus key is used to scroll down through the programming menu or decrease the value of the parameter within the menu...

Страница 9: ...0 P103 Motor 1 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P104 Motor 1 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 10: ...0 P303 Motor 3 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P304 Motor 3 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 11: ...0 P503 Motor 5 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P504 Motor 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 12: ...the display in case of error FULL radio remote control memory full Err the radio remote control is not recognized in either delete or write 6 3 Settable functions 6 3 1 General Open Close on main boar...

Страница 13: ...e free n o contact The opening closing action of the window can be set using the P104 P204 P304 P404 P504 P604 menu Supply voltage 12V for rain sensor Tension V Maximum Current mA 12V DC 100mA Please...

Страница 14: ...0 when a sensor intervenes the window goes to the position instructed by the sensor and remains there 6 3 7 Other parameters Parameters P101 P201 P301 P401 P501 P601 Add dEL rESE The parameter P101 P...

Страница 15: ...The radio remote control is now saved and the motors are controlled by the respective channels CH1 motor 1 CH2 motor 2 CH6 motor 6 End Repeat the procedure for any other radio remote controls Advance...

Страница 16: ...control to be saved press one of the arrow STOP or arrow buttons twice Now the second radio remote control is operational 7 OVERALL DIMENSIONS The container box is made of impact resistant ABS enginee...

Страница 17: ...Page 17 8 CONNECTION DIAGRAM OF THE STATION Fig 7 1 Main Board Fig 7 2 Expansion Modules...

Страница 18: ...4 station with the addition of a 230V ac module does not require any modifications of the power supply unit The 230V ac are powered directly from the mains network in this case it s not necessary to c...

Страница 19: ...tter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of payment Guarantee of good function of appliances agreed by the manufacturer implies that t...

Отзывы: