background image

Page 4 

1.  SAFETY INDICATIONS 

1.1. 

General notes 

 

ATTENTION:  Before  installing  this  appliance,  ensure  all  safety 
indications have been read carefully and understood in order to prevent 
contact  with  electricity,  injury  or  any  other  incident.  The  manual  should 
be conserved for further consultation at a later date. 

 

The  manufacturer  accepts  no  responsibility  for  damage  to  people, 

animals or things incurred by improper use. 

 

Use  for  any  applications  other  than  those  indicated  must  be  authorised 

by the manufacturer after technical review of the assembly. 

 

Plastic bags, polystyrene, small metal parts such as nails, staples etc. should 
be placed out of the reach of children as they constitute a potential source of 
risk. 

 

Do  not  use  solvents  or  jets  of  water  to  wash  the  appliance.  The  appliance 
should not be submerged in water. 

1.2. 

Notes for functioning and use 

 

This  device  is  intended  only  and  exclusively  for  the  use  for  which  it  was 
designed,  and  the  manufacturer  cannot  be  held  liable  for  damage  due  to 
improper use. 

Central  control  have  been  designed  and  constructed  exclusively  to  execute  maneuvers  for 
closing and/or opening windows, roll-up blinds, curtains and sunshades, assisted by the aid 
of sensors for rain, wind, brightness and temperature. 

Specific  use  is  reserved  for  automatic  ventilation  and  air-conditioning  of  rooms,  which  is 
carried  out  through  the  connected  motors; 

any  use  for  applications  other  than  those 

specified must be authorized by the manufacturer, upon technical verification. 

 

The  appliance  must  be  installed  by  competent  and  qualified  technical 
personnel.  Improper installation and use  make  the  unit  dangerous for  people 
and things. 

 

To ensure efficient separation from the grid, an approved type of bipolar pulse 
switch  should  be  used.  An  omnipolar  general  power  switch  with  minimum 
distance of 3 mm between contacts should be installed upstream of the control 
line.

 

 

Before  carrying  out  any  cleaning  or  maintenance,  make  sure  the  equipment 
has been disconnected from the electricity supply. To guarantee safe working 
conditions, we recommend all cables are disconnected. 

 

Attention: 

in the event of breakage or malfunction, switch the appliance off at 

the general switch and call for the services of a qualified technician. 

Содержание 1120.30

Страница 1: ...Codice 4420078 Edition 1407 CONTROL BOARD 1120 30 1120 31 1120 32 1120 33 1120 34 1120 35 UNIT FOR VENTILATION WITH SEVERAL 24V DC MOTORS MANUAL FOR INSTALLATION AND USE English...

Страница 2: ...ing and indications for use provided with the product indicate presumed conformity to the directives issued by the European Community The manufacturer holds the technical archive with documentation pr...

Страница 3: ...rs P005 P104 P204 P304 P404 P504 P604 13 6 3 3 Wind sensor Parameters P103 P203 P303 P403 P503 P603 13 6 3 4 Cron Timer input on main board Parameters P105 P205 P305 P405 P505 P605 13 6 3 5 Sensor pri...

Страница 4: ...control have been designed and constructed exclusively to execute maneuvers for closing and or opening windows roll up blinds curtains and sunshades assisted by the aid of sensors for rain wind brigh...

Страница 5: ...cal systems The equipment has double electrical insulation and thus does not require an earth wire All devices connected to the station must be earthed by the installer unless equipped with double ins...

Страница 6: ...or adjustment operation The electrical power supply system must be designed and implemented in compliance with current standards Caution Check that the electric power supply used corresponds to that s...

Страница 7: ...TING INFORMATION 6 1 General instructions The control unit is composed of a main board which is set up for insertion of expansion module boards The expansion module boards differ depending on the cont...

Страница 8: ...ugh the programming menu or increase the value of the parameter within the menu The minus key is used to scroll down through the programming menu or decrease the value of the parameter within the menu...

Страница 9: ...0 P103 Motor 1 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P104 Motor 1 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 10: ...0 P303 Motor 3 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P304 Motor 3 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 11: ...0 P503 Motor 5 Wind sensor function 0 2 F 0 Set the action when active as follows 0 none 1 open 2 close P504 Motor 5 Rain sensor function 1 2 F 2 Set the action when the input is active as follows 1 o...

Страница 12: ...the display in case of error FULL radio remote control memory full Err the radio remote control is not recognized in either delete or write 6 3 Settable functions 6 3 1 General Open Close on main boar...

Страница 13: ...e free n o contact The opening closing action of the window can be set using the P104 P204 P304 P404 P504 P604 menu Supply voltage 12V for rain sensor Tension V Maximum Current mA 12V DC 100mA Please...

Страница 14: ...0 when a sensor intervenes the window goes to the position instructed by the sensor and remains there 6 3 7 Other parameters Parameters P101 P201 P301 P401 P501 P601 Add dEL rESE The parameter P101 P...

Страница 15: ...The radio remote control is now saved and the motors are controlled by the respective channels CH1 motor 1 CH2 motor 2 CH6 motor 6 End Repeat the procedure for any other radio remote controls Advance...

Страница 16: ...control to be saved press one of the arrow STOP or arrow buttons twice Now the second radio remote control is operational 7 OVERALL DIMENSIONS The container box is made of impact resistant ABS enginee...

Страница 17: ...Page 17 8 CONNECTION DIAGRAM OF THE STATION Fig 7 1 Main Board Fig 7 2 Expansion Modules...

Страница 18: ...4 station with the addition of a 230V ac module does not require any modifications of the power supply unit The 230V ac are powered directly from the mains network in this case it s not necessary to c...

Страница 19: ...tter is valid as long as the purchaser possesses proof of purchase and completion of all agreed conditions of payment Guarantee of good function of appliances agreed by the manufacturer implies that t...