background image

Installation & Operation Manual | MI-WAVE3D  

 

 

© 

MASTERIMAGE 3D, Inc.

 

57 

 

<Cue name="Start 3D"> 

<Actions> 

<InvokeMethod name="Start" device="MasterImage"/> 

</Actions> 

</Cue> 

<Cue name="Stop 3D"> 

<Actions> 

<InvokeMethod name="Stop" device="MasterImage"/> 

</Actions> 

</Cue> 

<Cue name="3D Position"> 

<Actions> 

<InvokeMethod name="3Dposition" device="MasterImage"/> 

</Actions> 

</Cue> 

<Cue name="2D Position"> 

<Actions> 

<InvokeMethod name="2Dposition" device="MasterImage"/> 

</Actions> 

</Cue> 

<Cue name="Up/Down Stop"> 

<Actions> 

<InvokeMethod name="PFDStop" device="MasterImage"/> 

</Actions> 

</Cue> 

 

Once this file has been edited and saved the graphical interface of the Qube server 
will display the new cues that can be selected for future playlist creation.

 

 

Содержание MI-WAVE3D

Страница 1: ...Installation Operation Manual MI WAVE3D 55 MI WAVE3D Digital 3D Cinema System Installation Operation Manual Revision No 1 0 1...

Страница 2: ...ebruary 25 th 2014 Preliminary Document RJG PD 1 2 February 27 th 2014 Preliminary Document RJG Firmware Utility Changes 1 0 0 May 21 st 2014 First Release RJG 1 0 1 July 8 th 2014 Update RJG Automati...

Страница 3: ...X 323 301 7985 MASTERIMAGE 3D ASIA LLC 22F BYC HIGHCITY B D A 371 17 Gasan dong Geumcheon gu Seoul 153 803 South Korea TEL 82 2 3438 1600 FAX 82 2 3438 1698 MASTERIMAGE 3D EUROPE PLC Pinewood Studios...

Страница 4: ...iew 12 5 1 Liquid Crystal Polarization Modulator LCPM 12 5 2 Actuator 13 6 System Setup 14 6 1 Installation Options 14 6 2 Projector Lens Consideration 15 6 3 Initial Actuator LCPM Assembly 16 6 3 1 A...

Страница 5: ...ser Password 28 9 3 4 System Operation via the Monitor Application 29 9 3 5 Position Movement via the Monitor Application 30 9 3 6 3D Position 30 9 3 7 2D Position 31 9 3 8 Sync Polarity via the Monit...

Страница 6: ...AVE3D MASTERIMAGE 3D Inc 6 12 Appendix B MI WAVE3D Automation 47 12 1 Ethernet Automation 49 12 1 1 Doremi Server 49 12 1 2 Qube Server 55 12 1 3 GDC Server 58 13 Appendix C Installation Record 64 14...

Страница 7: ...quality 3D eyewear the MI WAVE3D provides the clearest and truest color 3D picture of any available liquid crystal 3D system This user manual provides all the information required for simple installat...

Страница 8: ...between 155mm and 165mm and centered on the LCPM as shown below 2 2 Heat Damage To avoid burning the polarizer film of the LCPM during the installation and setup procedure maintain the image size show...

Страница 9: ...projector MI WAVE3D is constructed from two specific Liquid Crystal LC panels that are accurately bonded to ensure effective polarization of the left and right images from the projector lens MI WAVE3D...

Страница 10: ...acking the MI WAVE3D Inspect the MI WAVE3D packaging box for any external damage Report any damage to shipper and to MasterImage 3D Bottom layer mounting frames 2 nd layer LCPM cooling fans Actuator B...

Страница 11: ...VE3D Liquid Crystal Polarization Modulator LCPM Actuator Control Box and Rack Mount Accessory Power Adaptor Sync Cable Actuator Cable Mounting Frames 3D Glasses LCPM Liquid Crystal P olarization Modul...

Страница 12: ...rization Modulator LCPM Stand Used to adjust the height and an gle of the LC Frame in respect to the projector lens Cooling Fan Cool Fan Connector Actuator Cable Connector Liquid Crystal Panel LC Fram...

Страница 13: ...Power Adaptor Jack Mounting Plate for LC P olarization Modulator Robot Chain Sync Cable Stroke 300mm LC Polarization Modulator installed on the Actuator USB Connector for F W Download 2D 3D GPIO Sync...

Страница 14: ...uator in front of the projector manually hold the LCPM in front of the projection lens so that an image width of between 155mm and 165mm is visible on the LC panel Figure 1 Image Width on LCPM Decide...

Страница 15: ...e actuator mounting frame in two directions depending on the amount of lens extension from the front of the projector In general both NEC and Barco projectors tend to have a shorter lens design than t...

Страница 16: ...h two supplied screws Figure 6 Figure 6 Fan Mounting 6 3 2 Attach LCPM Frame to Actuator 1 Attach the LCPM frame to the top side of the actuator assembly with the 2 supplied thumb screws Figure 7 Figu...

Страница 17: ...Figure 9 Height and Angle Adjustment Screws 6 3 4 Attach the Actuator Mounting Base Mount the actuator mounting base to the actuator mounting bar with 3 supplied screws Figure 10 Figure 10 Actuator Mo...

Страница 18: ...the projector use the screws Figure 13 to accurately set the height and angle of the LCPM Figure 13 Height and Angle Adjustment Screws IMPORTANT The LCPM must be installed perpendicular to the light...

Страница 19: ...4 2 Test Actuator Operation 3D Position Press and hold the Actuator 3D button for 1 second and release The Actuator will transition to the 3D position with the 3D button LED flashing and the cooling...

Страница 20: ...ition Press and hold the Actuator 2D button for 1 second and release The Actuator will transition to the 2D position with the 2D button LED flashing and the cooling fans will stop Once in the 2D posit...

Страница 21: ...UN button LED blinks during system stabilization with the GPIO or TTL sync signal The cooling fans will also be operational Once stabilization is complete the RUN button LED will be solid and the sync...

Страница 22: ...actuator is in the 3D position when the LCPM operation is stopped the cooling fans will remain operational to protect the LCPM from thermal damage Press and hold the actuator 2D button for 1 second t...

Страница 23: ...ntrol files for Series II projectors The Dark Time should be set to 350 S with the Delay being left at 120 S These figures are applicable to all frame rates and projector flash configurations Follow t...

Страница 24: ...ation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 24 8 2 2 Christie Series II File Settings for External Server Playback Figure 21 8 2 3 Barco Series II File Settings for External Server Playback Fi...

Страница 25: ...Site specific Auxiliary Lens Site specific Selected if Anamorphic Lens or WCL needed otherwise unselected Config 2 Measured Color Site Specific Create on site Target Color DC28_DCI_XYZE_314_351 Color...

Страница 26: ...witch to the ON position as indicated to Invert the sync polarity Figure 23 Figure 23 3D Phase Sync Polarity 9 2 Actuator 3D Position If necessary it is possible to change the actuator 3D position by...

Страница 27: ...You can use a different IP address that is suitable to your network 9 3 2 Execute the Monitor Application using a Web Browser Input the default IP address of the MI WAVE3D 192 168 10 95 into your web...

Страница 28: ...e New Password link in the upper right corner of the MI WAVE3D Web Server and the Change Password dialog box will be displayed MI WAVE3D Web Server shows all the system status information Status Ready...

Страница 29: ...Operation via the Monitor Application Click the RUN button to start the LCPM operation The color of the RUN button will change from black to green Input the current password mi Input a new password I...

Страница 30: ...sition Click the 3D button to move the actuator to the 3D position The color of the 3D button will change from black to green The color of the RUN button will change from black to green The indication...

Страница 31: ...ange from black to green The color of the RUN button will change from green to black The indication under Status will change from Running to Ready The cooling fans will stop operation and this will be...

Страница 32: ...3D Inc 32 9 3 8 Sync Polarity via the Monitor Application Check the current value of the Sync Polarity Depending on the condition of 3D material on screen change the Sync Polarity as required from Tr...

Страница 33: ...the 3D position of the Actuator If required by the installation requirements for the system the 3D Position can be changed from Left to Right accordingly Click Save Reset to accept any changes 9 3 10...

Страница 34: ...Sync Pulse Automation Reference Frequency via the Monitor Application Set the reference frequencies when the automation source is set to Sync Pulse Once the Automation Source has been set to Sync Pul...

Страница 35: ...with material of varying frequency or frame rate it may be necessary to apply 2D Delay Time to the system to prevent unwanted 2D transition Enter the required 2D Delay Time for your particular situat...

Страница 36: ...ion Click Network Configuration to access the settings window Enter the IP Address Gateway Subnet Mask Primary DNS and Secondary DNS of your network accordingly Click the Save Config button to accept...

Страница 37: ...etting for the Fan Speed The default is HIGH You can reduce the noise of the cooling fans by adjusting the fan speed The speed can be changed to either MID or LOW accordingly Click Save Reset to accep...

Страница 38: ...AGE 3D Inc 38 9 3 15 Sync Source via the Monitor Application Check the current setting for the Sync Source The default is GPIO Choose the option for TTL if the system is being used in a non cinema app...

Страница 39: ...tains a log function that stores the last 200 records of activity including any errors that occurred In order to access the log file click Log at the top of the Monitor Application The Log File will b...

Страница 40: ...on Source Setting REFERENCE 1 72Hz Reference Sync Frequency Setting REFERENCE 1 72Hz ON Reference Sync Frequency Enabled REFERENCE 1 72Hz OFF Reference Sync Frequency Disabled POLARITY TRUE Sync Polar...

Страница 41: ...c 41 9 3 17 Factory Default via the Monitor Application Should it be necessary for any reason to reset the system to Factory Default this can be achieved by clicking the Default button This can be com...

Страница 42: ...g 10 1 Error Indication via LED Display Error code Description E01 No connection with the Actuator E02 No movement of the Actuator normally E03 Malfunction status of the Actuator E04 No operation of t...

Страница 43: ...sword M 3DuploadASIA 2 Download and install the MI WAVE3D firmware upgrading utility Installed shortcut MITftp exe 3 Download and save the latest firmware file having a hex file extension Example MI W...

Страница 44: ...your individual site network requirements Enter the device IP address and Port Number Default IP 192 168 10 95 Port 69 Device s IP Address Default 192 168 10 95 Hex file name Hex file size Log message...

Страница 45: ...I WAVE3D MASTERIMAGE 3D Inc 45 5 Select the file to be used and click Open 6 Click the Upgrade button to start the upgrade of the selected file to the system 4 Click the Open button to select the firm...

Страница 46: ...the Upgrade button 8 You will see the Success Firmware Upgrade message in the utility after the progress bar reaches the end Click the Exit button to close the utility after successful upgrade Note S...

Страница 47: ...x 12V threshold LM2901H 5 31 PRJ_SYNC 3 9 Vertical sync pulse 5 28 PRJ_COM_nUP 4 2 LCPM 3D command Low Pulse 200ms 5 21 GND 5 20 21 22 28 29 30 31 Ground PRJ_COM_nDOWN 6 3 LCPM 2D command Low Pulse 20...

Страница 48: ...5 9 pin Automation DSUB9 GPIO Comm Direction DSUB15 Description Comments Pin name Pin number Pin number NC 1 NC 2 SYNC 3 7 Vertical sync pulse Comparator 24V max 12 threshold LM2901H NC 4 GND 5 13 14...

Страница 49: ...ver 1 Within the server menu open Device Manager Menu DTS Digital Cinema Device Manager 2 Click the Add button and the list of devices will display shown right 3 Select the Raw option to create Master...

Страница 50: ...control the MI WAVE3D The files required are MasterImage Start MasterImage Stop MasterImage 2D MasterImage 3D and MasterImage Up Down Stop These are created in the Macro Editor option of the server me...

Страница 51: ...ditor screen Repeat this process for the other four required macros MasterImage Stop MasterImage 2D MasterImage 3D and MasterImage Up Down Stop 3 To insert an action for each newly created macro selec...

Страница 52: ...n completed click the OK button 6 Repeat this step for the remaining four macros entering the corresponding message text MasterImage Stop Stop n MasterImage 2D PFD DOWN n or 2D n MasterImage 3D PFD UP...

Страница 53: ...MasterImage macros will be included in a file named MasterImage_cueslib This will remove the requirement for the information to be entered manually as described in the above steps The MasterImage_cue...

Страница 54: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 54...

Страница 55: ...name Address value address value Key name Port value port value Configuration Device Devices 2 Complete the red fields with the details of the MasterImage MI CLARITY3D where Device Name is MasterImag...

Страница 56: ...e 2Dposition Instructions Send PFD Down x0D x0A Send Instructions Method Method name PFDStop Instructions Send PFD Stop x0D x0A Send Instructions Method StreamDevice The symbols x0D x0A are necessary...

Страница 57: ...ue name 3D Position Actions InvokeMethod name 3Dposition device MasterImage Actions Cue Cue name 2D Position Actions InvokeMethod name 2Dposition device MasterImage Actions Cue Cue name Up Down Stop A...

Страница 58: ...cribed below are specific to the GDC SX 2001 server If information is required for different models please contact GDC directly 1 In the SMS Main Menu click the Control Panel button and log on as Main...

Страница 59: ...n Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 59 The MI WAVE3D must be added as a device within the GDC server configuration 3 Select the Devices tab and click the Add button The following screen wi...

Страница 60: ...enter the configuration settings for the MI WAVE3D IP Address and Port Number 6 In the Transport option select TCP and in the Linefeed Type select CR and ensure the Status is set to Enabled 7 Once all...

Страница 61: ...ation Manual MI WAVE3D MASTERIMAGE 3D Inc 61 9 Click the Add button to create a new event In this case name the event START 10 Click the Enter button and enter the command value for the event Again in...

Страница 62: ...Event Name UP DOWN STOP Enter Value PFD STOP 12 Once all macros have been created return to the Actions tab of the Automation screen to create the events that are needed to communicate This is done by...

Страница 63: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 63 15 Once all event actions have been created click the Save button followed by Yes...

Страница 64: ...below is an example of the installation record form to be filled out once the MI WAVE3D has been set up and configured For a copy of the form to be filled out contact your equipment provider or email...

Страница 65: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 65 14 Appendix D Dimensional Drawings Liquid Crystal Polarization Modulator LCPM...

Страница 66: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 66 Actuator...

Страница 67: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 67 Mounting Frame Assembly for Short Projector Lens...

Страница 68: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 68 Mounting Frame Assembly for Long Projector Lens...

Страница 69: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 69 Installation Example Using Mounting Frame Assembly for Long Projector Lens...

Страница 70: ...Installation Operation Manual MI WAVE3D MASTERIMAGE 3D Inc 70 End of Manual For additional information go to www masterimage3d com...

Отзывы: