background image

 

5

CAUTION!

GROUND REQUIRED

FOR SAFE OPERATION

WARNING LABELS AND SAFETY INSTRUCTIONS

 

 

 
This symbol is the safety-alert symbol.  When you see this symbol on your cabinet or in this 
manual, be alert to the potential for personal injury or damage to your equipment. 
 
 

Be sure you understand all safety messages and always follow recommended precautions and safe operating 
practices. 
 
 
 

 
NOTICE TO EMPLOYERS

  

 

You must make sure that everyone who installs, uses or services your cabinet is thoroughly familiar 
with all safety information and procedures. 

 
Important safety information is presented in this section and throughout this section and throughout the 
manual.  The following signal words are used in the warnings and safety messages: 
 

DANGER:

    Severe injury or death will occur if you ignore the message. 

           

WARNING:

  Severe injury or death can occur if you ignore the message. 

 

CAUTION:

   Minor injury or damage to your cabinet can occur if you ignore the message. 

 

NOTICE:

      This is important installation, operation or service information.  If you ignore the           

        

message, you may damage your cabinet. 
 

The warning and safety labels shown throughout this manual are placed on your Master-Bilt Products 
cabinet at the factory.  Follow all warning label instructions.  If any warning or safety labels become 
lost or damaged, call your customer service department at (800) 684-8988 for replacements. 

 

 

 

This label is located on top of the electrical control 

 This label is attached to the cabinet power cord 

          label and on the wiring channel. 

 

 

 

on models with a power cord. 

 

 
 
 
  
 
 
 
 
 

 

 

Содержание TAF-27 ERC2 s

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 228 90000 Rev 05 04 04 bhs...

Страница 2: ...2...

Страница 3: ...TRUCTIONS 6 Inspection for ShippingDamage 6 INSTALLATION INSTRUCTIONS 6 General Instructions 6 Electrical 6 Leg and Condensate Pan Installation 7 ELECTRONIC REFRIGERATION CONTROL ERC 8 FINAL CHECK LIS...

Страница 4: ...If this case is to be located against a wall there should be at least 6 space between the wall and the back of the case see page 7 This space will allow for the circulation of air behind the case whi...

Страница 5: ...ing signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUT...

Страница 6: ...if the cabinet is malfunctioning or if there is a drainpipe leaking MECHANICAL Remove front grille and check refrigeration lines to see that they are free not touching each other or compressor Spin co...

Страница 7: ...temperatures for short periods of time 6 When replacing burned out fluorescent tubes be sure that the electrical power to the lighting circuit is turned off ELECTRICAL WARNING Before servicing electr...

Страница 8: ...s The TAF 27 models are cord connected and operate on a 15 amp 115 60 1 circuit The TAF 48 and TAF 74 models have two junction boxes mounted on top of the cabinet at the right rear for permanent conne...

Страница 9: ...T to accept the new time Step 5 Press DOWN to go to the next parameter Set point Temperature cut out Step 6 Press SET to change the set point temperature Step 7 or Press UP or DOWN to go to the desire...

Страница 10: ...Status dSPL Information shown on the display during operation conditions tdAy time of day rSP zone temperature CyCL cycle between time and zone temperature Epr evaporator coil temperature rSP Clock Fo...

Страница 11: ...e Range from 0 to 15 min 2 for LT 0 for MT Pump Down Pudn Pump down duration Range from 0 to 59 min 0 min Drip Time driP Drip time duration Range from 0 to 59 min 2 for LT 0 for MT Setpoint Differenti...

Страница 12: ...on the display Press SET to accept the change Press DOWN to go to Defrost Start Time dEF1 Press SET to change the time Press UP or DOWN until the 11 59 PM appears on the display Press SET Press DOWN...

Страница 13: ...s in the probe the control has LED functions as a diagnostic tool When power is supplied to the control the LED will turn on and will remain on as long as this condition is satisfied When there is a f...

Страница 14: ...Compressor starts and runs but cycles on overload A Low voltage B Dropped phase 3 phase C Overload protector defective D High head pressure see 1 6 Compressor will not start hums but cycles on overloa...

Страница 15: ...Gasket 37 01207 37 01211 37 01211 Door Handle 35 01488 35 01488 35 01488 Door Hinge Assembly A35 01501 A35 01501 A35 01501 Door Light Switch 35 01506 35 01506 35 01506 Door Opening Trim 29 01481 29 01...

Страница 16: ...ster Bilt at 800 684 8988 The customer service department at Master Bilt should be contacted at the time of sale or disposal of your cabinet so records may be kept of its new location If you sell or g...

Страница 17: ...17...

Страница 18: ...18...

Отзывы: