ELECTRICAL 
 

 
WARNING 
 

Before servicing electrical components in the case or the doors or doorframes make sure all power to 
case is off.  Always use a qualified technician.

  

 
 

PANEL STORAGE 
 

To comply with Sanitation requirements this cabinet must be mounted on casters, legs (6” high min.) or the 
base must be sealed to the floor. The casters provided with this case screw into the holes from which the 
shipping bolts were removed.  
 

Forks must be 4 

ft.in length to 
adequately support 

panels

 

                            

Figure # 1 

When panels must be stored at the job site prior to erection is very important that they be property stacked 
and covered.   In doing this panels will be protected against staining from moisture and sunlight and damage                   
by workmen and traffic.                                                                                              
 

3/4" X 3/4"

wood spacer

Groove edge of panel down

2 X 4 wood
frame

 

                                

Figure # 2 

Whenever possible panels should be stored indoors panels stored indoors may be stored in their original 
factory crates. If it is necessary to store panel’s outdoors, they should be stacked vertically on skids, with 
spacers between the panels.   This protects the panel edges and provides proper ventilation.  This method of 
stacking permits drain-off of condensation moisture, which comes from temperature changes and guards 
against the resultant formation of white rust stains or oxidation. (

See

 

Figure #2

).  Panels should be covered 

with a waterproof covering to protect them from the elements of weather.  Master-Bilt recommends black 
polyethylene sheeting, which keeps sunlight out and eliminates the “greenhouse” condition, which occurs 
when clear plastic is used.  In heavy traffic areas, it is advisable to place protective rails around stacks of 
panels to guard them from any possible damage. 
 

 
 

 

Содержание CL-156

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 090 90000 Rev 05 20 03 LocN...

Страница 2: ...2...

Страница 3: ...ns 6 Notice to store owners managers 6 Electrical 7 Panel Storage 7 Cam Fasteners 8 Level Floor 9 Caulking 9 Floor Assembly 10 Celing and Wall Penal Assembly 10 Door and Frame installation 10 Refriger...

Страница 4: ...ys of sun or near a direct source of radiant heat or airflow This will adversely affect the case and will result in poor performance NOTICE Read this manual before installing your cabinet Keep the man...

Страница 5: ...ing signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUT...

Страница 6: ...the equipment clean and sanitary so it will meet your local sanitation codes 3 Rotate your stock so that older stock does not accumulate A First In First Out rotation practice will keep the products...

Страница 7: ...spacer Groove edge of panel down 2 X 4 wood frame Figure 2 Whenever possible panels should be stored indoors panels stored indoors may be stored in their original factory crates If it is necessary to...

Страница 8: ...will be as shown Cam Wrench Hook in Open Position Figure 3 NOTE All cam lock locking arms must be in the open position before attempting to lack panels together Push panels together and turn cam wret...

Страница 9: ...er in both length and width so as to property support the floor panels when the walk in is assembled and the product load is in place Shimming just the outer edges of just the corners of the floor pan...

Страница 10: ...should be completely aligned and cam fasteners completely tightened If wall panels appear to have a stair step effect on the top horizontal egde as thy are being assembled the foor is not level At thi...

Страница 11: ...drain pan of evaporator coil seal around drain line with silicone or butyl caulking to prevent moist air entering box from outside Start compressor and allow running at least 24 hours before committin...

Страница 12: ...ply to door frame TEMPERATURE CONTROLS On the CM models the Temperature Control is on the end penel of the blower housing These controls have an off position at full counter clockwise position and sho...

Страница 13: ...oting Guide 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective 2 Low back pressure and low head pressure A Restriction in system B Refri...

Страница 14: ...E 070UU 1 SK 3 3A R35XZ070UU 1 SK 1 C12X 070UU 4 SK 1 W46X 070UU 3 28X63 RH NSF 1092 DGT SK 2 2P D28RX070UU 1 F35E 07 UU 1 F35S 070UU 1 TOTALS 12 Vapor Proof Light Globe for door panel 23 00594 1 1 Di...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: