FLOOR ASSEMBLY 

 
Lay out all floor panels in sequence as shown on assembly drawings and make sure they are level.  Fasten 
these panels as evenly as possible to one another. Tighten the cam fasteners all the way so that the panels 
are aligned evenly and as snug one to the other as possible. 
 
 

CEILING AND WALL PANEL ASSEMBLY 
 
NOTE: When facing the interior of the wall panel, all vertical latch access holes should be on the left 
side of the panel. 
 

Lay out wall panels in accordance with the assembly drawings supplied with the walk-in.  It is suggested to 
begin by assembling the front of the walk-in first.  The front is normally considered that portion of the walk-in 
that has the walk-thru door in it.  However, if the walk-in is to be installed inside an existing building or space 
with two or three of the walk-in walls restricted, assembly then may be accomplyshed easier by beginning at 
the rear (opposite the door wall).  Assemble the wall panels of the front portion until you get to both corners 
and then start to assemble roof sections so as to secure that portion of the walls that are already in place.  As 
wall panels are assemled, they should be completely aligned and cam fasteners completely tightened.  If wall 
panels appear to have a stair-step effect on the top horizontal egde as thy are being assembled, the foor is not 
level. At this point, you must stop immediately and take corrective measures to poperty level floor panels. All 
walls and corners can be assembled prior to the installation of the ceiling.  As ceiling panels are assembled, 
each one should be property aligned to the adjoining ceiling and wall panels and locked into position as tightly 
as possible. 
 
 

DOOR AND FRAME INSTALLATION 

 

NOTE: It is very important that the floor be level where that walk-in is to be installed.  Shims may be 
installed under the floor, if necessary, to ensure that the entire walk-in is square and plumb. 
 

SHIMS

FLOOR PANEL

1/4" SPACE

ROOF PANEL

 

                            Figure #9 

 
1.  Set wall and roof panels, except the roof panel above door frame and adjoining corner panel to the right 

side of the door frame (when facing the inside of the door), in accordance with the Walk-in Installation 
instructions and plan drawing supplied.  (Make sure all are assembled square and plumb to ensure proper 
operation.) 

2.  Set door and frame in place. 
3.  Place a spirit level against the door frame leg (inside door opening) to ensure that it is correctly aligned 

vertically, and latch the door frame to the adjoining wall/corner panel. 

Содержание CL-156

Страница 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 090 90000 Rev 05 20 03 LocN...

Страница 2: ...2...

Страница 3: ...ns 6 Notice to store owners managers 6 Electrical 7 Panel Storage 7 Cam Fasteners 8 Level Floor 9 Caulking 9 Floor Assembly 10 Celing and Wall Penal Assembly 10 Door and Frame installation 10 Refriger...

Страница 4: ...ys of sun or near a direct source of radiant heat or airflow This will adversely affect the case and will result in poor performance NOTICE Read this manual before installing your cabinet Keep the man...

Страница 5: ...ing signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUT...

Страница 6: ...the equipment clean and sanitary so it will meet your local sanitation codes 3 Rotate your stock so that older stock does not accumulate A First In First Out rotation practice will keep the products...

Страница 7: ...spacer Groove edge of panel down 2 X 4 wood frame Figure 2 Whenever possible panels should be stored indoors panels stored indoors may be stored in their original factory crates If it is necessary to...

Страница 8: ...will be as shown Cam Wrench Hook in Open Position Figure 3 NOTE All cam lock locking arms must be in the open position before attempting to lack panels together Push panels together and turn cam wret...

Страница 9: ...er in both length and width so as to property support the floor panels when the walk in is assembled and the product load is in place Shimming just the outer edges of just the corners of the floor pan...

Страница 10: ...should be completely aligned and cam fasteners completely tightened If wall panels appear to have a stair step effect on the top horizontal egde as thy are being assembled the foor is not level At thi...

Страница 11: ...drain pan of evaporator coil seal around drain line with silicone or butyl caulking to prevent moist air entering box from outside Start compressor and allow running at least 24 hours before committin...

Страница 12: ...ply to door frame TEMPERATURE CONTROLS On the CM models the Temperature Control is on the end penel of the blower housing These controls have an off position at full counter clockwise position and sho...

Страница 13: ...oting Guide 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective 2 Low back pressure and low head pressure A Restriction in system B Refri...

Страница 14: ...E 070UU 1 SK 3 3A R35XZ070UU 1 SK 1 C12X 070UU 4 SK 1 W46X 070UU 3 28X63 RH NSF 1092 DGT SK 2 2P D28RX070UU 1 F35E 07 UU 1 F35S 070UU 1 TOTALS 12 Vapor Proof Light Globe for door panel 23 00594 1 1 Di...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Отзывы: