63
Attachment 2: CV 49 - MASSOTH configuration table
Bit Value
OFF (Value=0)
ON
Note
0
1
Parallel data transfer only
parallel data transfer automatic detection
of serial/parallel
1
2
Digital load control = OFF
Digital load control = ON
2
4
Analog load control = OFF
Analog load control = ON
3
8
---
---
4
16 Massoth bus
SUSI bus
Attachment 3: CV 113 - Switch. output commands
Value
Application
Note
0 - 16
0 = Switch function with light key,
1 ... 16 = Switch function with F-key No. 1-16
+ 64
Switching output "on" in reverse Only
additional value must be added
+ 128
Switching output „on“ in forward Only
additional value must be added
Attachment 4: CV 114 - Special functions A3
Value
Application
Note
0
0 = Steady „on“
(Standard operation)
1 - 15
Flashing symmetrical
(Time base 0,25 sec/value)
symmetric flashing
+ 64
Short term function (Monoflop)
(Time base 0,25 sec/value)
output switches off after time
out
additional value must be added
+ 128
Asymmetric flashing (1/3 on, 2/3 off)
short „on“, long „off“
additional value must be added
+ 192
Asymmetric flashing (2/3 on, 1/3 off)
short „off“, long „on“
additional value must be added
Содержание eMOTION S
Страница 1: ...eMOTION S Anschlussanleitung eMOTION S Installation Manual Art Nr Item No 82x2100 Version 1 0 ...
Страница 45: ...45 ...
Страница 69: ...69 ...