57
Table of configuration variables
CV Description
A Range Note
201 Add. sound 1: Individual volume level
*
0...3 0= 25% volume level
1= 50% volume level
2= 75% volume level
3= 100% maximum volume
202 Add. sound 2: Individual volume level
*
0...3
203 Add. sound 3: Individual volume level
*
0...3
204 Add. sound 4: Individual volume level
*
0...3
205 Add. sound 5: Individual volume level
*
0...3
206 Add. sound 6: Individual volume level
*
0...3
207 Add. sound 7: Individual volume level
*
0...3
208 Add. sound 8: Individual volume level
*
0...3
209 Add. sound 9: Individual volume level
*
0...3
210 Add. sound 10: Individual volume level
*
0...3
211 Add. sound 11: Individual volume level
*
0...3
212 Add. sound 12: Individual volume level
*
0...3
217 Volume turn-on phase (since V1.3)
*
0 ... 3
218 Volume standing phase (since V1.3)
*
0 ... 3
219 Volume turn-off phase (since V1.3)
*
0 ... 3
220 Volume driving phase (since V1.3)
*
0 ... 3
229 Trigger threshold 1: Multiple-contact
switch digital mode (since V2.2)
16 0 ... 255
230 Trigger threshold 2: Multiple-contact
switch digital mode (since V2.2)
32 0 ... 255
231 Trigger threshold 2: Multiple-contact
switch digital mode (since V2.2)
48 0 ... 255
232 Trigger threshold 4: Multiple-contact
switch digital mode (since V2.2)
112 0 ... 255
233 Trigger threshold 5: Multiple-contact
switch digital mode (since V2.2)
160 0 ... 255
234 Sound on accelerate, Multiple-contact
switch (since V2.2)
11 0 ... 255
235 Switching timer
4
0...16 (0,15 sec per value)
0 = deactivated
Содержание eMOTION S
Страница 1: ...eMOTION S Anschlussanleitung eMOTION S Installation Manual Art Nr Item No 82x2100 Version 1 0 ...
Страница 45: ...45 ...