15
CV-Values
CV‘s are usable with loco addresses (L), switch addresses(S) or with both (LS).
CV
Description
Default
L/S
Range
Note
1
Loco address
(Standard short)
3
L
1-127
2
Programming Lock
77
LS
0 + 77
5+6 Register mode: Reg 6 = CV-addr. ,
Reg 5 = Value
---
---
---
7
Software Version
(15)
---
---
7
Decoder-Reset function
(2 ranges available)
---
---
55 / 77
See attachment 4
8
Manufacturer ID
123
---
---
17 Long loco address (high byte)
128
L
128 ..
10239
18 Long loco address (low byte)
29
Configurations Register NMRA
128
LS
See attachment 1
31 Switch address SW1 high
0
S
1 .. 2048
32 Switch address SW1 low
1
S
41 F1 Command Allocation
1
L
0..16
0 = Light
1..16 = Function
42 F2 Command Allocation
2
L
0..16
0 = Light
1..16 = Function
50 Switching direction
0
LS
0,1
0 = normal
1 = invers
51 F1 Special Function
67
LS
See attachment 2
52 F2 Special Function
67
LS
See attachment 2
71
Voltage for W1 output
(A1 + A2)
15
LS
0..15
15 = full
Voltage
75
Time delay for automatic reverse
S1
0
LS
0..255
0= off; 1…255=
0.25sec per step
121 A1: special function RC servo
0
L
0..13
Attachment 3