17
CV-Values
CV‘s are usable with loco addresses (L), switch addresses(S) or with both (LS).
CV
Description
Default
L/S
Range
Note
122 A1: lower limit
16
L
5..50
Must be adjusted
to the RC servo
123 A1: upper limit
32
L
5..50
Must be adjusted
to the RC servo
Attachment 1. (CV 29) – NMRA-Config
Bit
Off (Value=0)
Application
On
Value
Note
0
Normal Driv. Direction
Reverse Driv.Direction
1
1
14 Speed Steps
28 Speed Steps
2
important for light
settings
5
Short Address
(CV 1)
Long Address
(CV 17+18)
32
7
Loco Address
Switch Address
128
Attachment 2. (CV 51 - 52) – Special functions A1 + A2
Value
Application
Note
0
0 = Continuous Operation
Standard Function
1..15
Continuous Symmetric Flashing
(Time Base 0,25 sec per unit)
Output flashes symmetrically
(1..15)
+ 32
Enhance timebase to 2 sec.
Usable for all time programs. The
additional value must be added.
(1..15)
+64
Short Term Function, Monoflop
(Time Base 0,25 sec per unit)
Switch Function!
Output switches off automatically after
reaching the time limit. The additional
value must be added.
(1..15)
+ 128 /
+192
Asymmetrical Flashing (Short) / Asymmetri-
cal Flashing (Long)
1/3 ON – 2/3 OFF
Short ON/Long OFF
The additional value must be added.