Site
Requirements
14
Need help? Contact [email protected]
Site Preparation
Manual
Temperature and Humidity
Temperature and humidity, both in the print production and in the storage areas can
affect the print output results. If not maintained within the recommended values, as
shown below, they may have an adverse effect on the print quality and/or damage
sensitive electronic devices in the system.
Print Production Area
Room temperature: 18°C - 30°C (68°F - 86°F)
Suggested Relative humidity: 30% – 70%
Storage Area
Max Room temperature: 30°C (50F)
Ventilation and Fume Extraction
Important! Material fumes emitted during printing and not properly removed from the
printer can cause a significant reduction in print quality and model collapsing
To ensure proper operation of the printer and prevent the accumulation of hazardous
vapors, sufficient ventilation must be provided by the customer to exchange the air in
the area surrounding the MASSIVIT 1800 printer. The MASSIVIT 1800 printer is equipped
with a built-in fume extraction system but nevertheless the customer must ensure that
the site and the area surrounding the MASSIVIT 1800 printer complies with all applicable
local legislation and guidance relating to ventilation and
Direct printer ventilation
Capacity: 18 CFM (
30
𝑚𝑚
3
/
ℎ𝑜𝑜𝑜𝑜𝑜𝑜
)
Air hose Connection size: 254 mm / 10” diameter