Masport Inbuilt Gas Fireplace
- 18 -
TROUBLE - SHOOTING
The following table lists possible problems and their likely causes. Most of these will require a
professional serviceman and we recommend that this work be performed by an Authorised Installer. If a
problem cannot be solved after referring to this table, please call your Masport gas fire Dealer for help.
PROBLEM
POSSIBLE CAUSE(S)
SOLUTION
Pilot will not light, and
Piezo igniter does not give a
strong blue spark.
Faulty electrode wire
connection(s).
Make sure connections are
firm, check wire.
Pilot will not light even
though there is a strong blue
spark.
Incorrect lighting
procedure.
No gas supply at heater.
Pilot filter or jet blocked.
No fuel in LPG system.
Follow the instructions in
this manual.
Check for closed gas
valve(s) or faulty gas
supply lines.
Replace filter in control
valve - clean jet.
Replenish LPG supply.
Burner will not light (EIS
models).
Thermostat (if fitted) is
switched to OFF or set to a
low temperature.
Thermostat defective, or
thermostat wiring to
heater is faulty.
Check thermostat setting.
Switch to ON or turn to a
higher temperature.
If wiring is undamaged
and the connections are
sound at each end,
thermostat may need
replacing.
Smell of flue gas in the
room.
Flue gas spilling from the
draught diverter at the
rear of the heater.
Check for flue blockage,
negative air pressure in
the room or circumstances
causing down draught.
Smell of gas in the room.
Pipe fittings may be
leaking.
Check all joints for leaks,
including the gas supply
system, the pilot light
supply tube, the main
burner supply tube and all
connections to the control
valve and pressure re-
ducing valve (Piccolo
models).
Use ONLY a proper leak
check solution. NEVER
USE AN OPEN FLAME
TO CHECK FOR LEAKS
Содержание MADRID