5 Masport Clutha - Technical Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overall Dimensions 

 

Net Weight of the Burner 

118 kg 

 

Test Method 

Emissions 

mg/MJ 

Emissions 

g/kg 

Efficiency 

Authorization 

No 

Real-Life Test  
Canterbury Method V1.6 (ULEB) 

 

 

 

 

 

National Environment Standard  
AS/NZS 4012/13:2014 

 

0.46g/kg 

 

 

  

Approx. Heating capability  

Small to Medium Homes (2~3 Bedrooms) 

 

 

Flue Shield 

900mm Long SS Double Flue Shield (Included in the Masport flue 
kit) 

Flue System 

Std 4.2M Long, 150mm Flue System (GDFLU013M) or Flue System 
that has been tested to & comply with AS/NZS 2918:2001 Appendix F   

** For installation in Canterbury & South of Canterbury, we recommend extending 200 inner 
casings within 250~300 from flue termination. Also, we recommend not to use Masport Opti 
or equivalent flue kits in this area, as they take ceiling or external cold air and cool the flue 
casings, leading to accelerated creosote build-up in the main flue pipe.  

Floor Protector Requirement 

Ash Floor Protector or Steel Floor Protector  

 

Minimum  Clearances  to  Combustibles:  Parallel,  Corner  &  Alcove  configurations  with  Minimum 

2.4 m ceiling height. 

Parallel Installation 

Corner Installation 

 

 

 

 

 

 

 

 

 

 

 

 

E- Cooktop Corner to Wall  

144 mm 

C- Glass to Floor Protector Front  

300 mm 

H- Flue Centre to Wall 

384 mm 

D- Floor Protector Side  

117 mm 

 

 

 

F- Flue Centre to Rear Wall 

231 mm 

 

 

 

G- Flue Centre to Side Wall 

573 mm 

N- Flue Centre to Floor 
     Protector Front 

656mm 

 

 

 

 

R- Flue Centre to Wall Corner 

543 mm 

 

 

 

WW- Overall Width of Fire 

495 mm 

K- Floor Protector Depth  

887 mm 

DD- Overall Depth of Fire 

524 mm 

 

 

HH- Overall Height of Fire  

894 mm 

Seismic Restraint

 - In New Zealand, it is a requirement that the wood burner and floor protector are 

secured to prevent shifting in the event of an earthquake.  This is best done by fastening the wood burner 
right through the protector to the floor, using 8mm Dyna Bolts [ concrete floors] or 8mm coach screws or 
equivalent fasteners [ wooden floors]. Seismic holes are located at the rear of the burner. 

I-

 

Floor Protector Front Edge

428

 

mm

J-

 

Floor Protector Width

729 mm

L-

 

Floor Protector Diagonal

1199 mm

M-

 

Floor Protector Side

998 mm

A-

 

Rear Panel to Rear Wall

B-Cooktop Edge to Side Wall

C-

 

Glass to Floor Protector Front

68

 

mm

325

 

mm

300 mm

35

 

mg/MJ

CRC 231303

CRC 231301

66%

NZ National Environmental Safety Test Standard

 

-

 

AS/NZS 2918:2001

NZ National

 

Environmental Test

 

Standards

 

-

 

AS/NZS 4012:2014 and AS/NZS 4013:2014.

 

Environment Canterbury’s Real-life test

 

-

 

Canterbury test method CM1.6

Clutha

 

burner model has

 

been tested and complies

 

with

 

the

 

following standards & tests:

495mm Wide x

 

524mm Deep x

 

894mm High

Содержание CLUTHA

Страница 1: ...CE Manufactured in New Zealand by GLEN DIMPLEX NEW ZEALAND LIMITED P O Box 58473 Botany Manukau 2163 Ph 0800 666 2824 Fax 09 274 8472 Email sales glendimplex co nz Web www glendimplex co nz Part No 599586 V1 0 Glen Dimplex New Zealand Ltd reserves the right to change specifications the content of this manual or the design of its product without prior notice ...

Страница 2: ...N AND PAINT CURING 8 12 FUEL 8 12 1 WOOD MOISTURE 8 13 1 KINDLING INTERMEDIATE AND MAIN WOOD DETAIL 8 13 2 INITIAL LIGHT UP WITH KINDLING AND INTERMEDIATE LOAD 9 13 3 INTERMEDIATE LOAD 2 AND MAIN LOAD 9 13 4 CONTROLLING THE HEAT OUTPUT 9 13 5 REFUELING 9 14 ASH 10 15 OPTIMIZING THE BEST PERFORMANCE FROM YOUR HEATER 10 16 MAINTENANCE 10 11 17 REPLACEMENT PARTS 11 12 18 COMMON ISSUES AND PROBLEM SOL...

Страница 3: ...er hotter burn This type of construction makes the heat durable and can reduce service costs in the long run 2 Items supplied with the fire 1 x Masport ceiling plate 1 x St St Main Baffle 7 x Ceramic Bricks 1 x Installation and Operation Manual which includes The Technical and Clearance Specification Installation guidelines The Brick Baffle Layout 3 Handling and Transport The Clutha appliance has ...

Страница 4: ...on concerning the use of the appliance by a person responsible for their safety Do not leave children unattended near the alighted fire and keep them well away from the fire when in use Supervise young children to ensure that they do not play with the appliance Do not use flammable liquids or aerosols to start or rekindle the fire Also do not use such flammable materials near this appliance when o...

Страница 5: ...otector Front 300 mm H Flue Centre to Wall 384 mm D Floor Protector Side 117 mm F Flue Centre to Rear Wall 231 mm G Flue Centre to Side Wall 573 mm N Flue Centre to Floor Protector Front 656mm R Flue Centre to Wall Corner 543 mm WW Overall Width of Fire 495 mm K Floor Protector Depth 887 mm DD Overall Depth of Fire 524 mm HH Overall Height of Fire 894 mm Seismic Restraint In New Zealand it is a re...

Страница 6: ... Factor Single layer of continuous material 12mm 0 4 Single layer of continuous material 25mm 0 3 Two spaced layers of continuous material 12mm 12mm 0 2 Clearance factors for heat shield which is more than 45 degrees off the vertical Heat Shield Construction Minimum Air Gap Dimension Clearance Factor Single layer of continuous material 12mm 0 8 Single layer of continuous material 25mm 0 6 6 Ash He...

Страница 7: ... have an impact on how the flue system performs and may need additional components added to remedy these issues flue casings other than std height must be braced in accordance with relevant building codes Flue installations other than a std vertical type are not recommended however if an installation requires offsets guidelines are set out with AS NZS 2918 2001 and must be followed All flue pipe j...

Страница 8: ...servatives or impregnated with chemicals or glue Chipboard particleboard or laminated board Painted stained or oiled Driftwood or other salt impregnated wood Burning such materials is not good for the environment it can also damage the firebox and put you at the risk of voiding the warranty your Masport heater In NZ radiata pine or macrocarpa are the most commonly available softwood species suitab...

Страница 9: ...trolling the heat output Once the main load has a well established flame the air control can now be adjusted to a lower setting Do not turn the air control directly from the high setting to low adjust to approximately half setting wait for around 5 10mins the adjust to the lowest setting Adjusting directly from high to low will starve the fire of oxygen and result in a poor burn 13 5 Refueling Ref...

Страница 10: ...heater on the low setting permanently and after long periods on the low setting it is recommended the heater is run on high to burn away any unwanted built up of particulate within the heater and flue system NOTE For the heater to perform optimally it must have a good air supply in today s air tight homes this can an issue so it is advised that an adequate fresh air supply be fitted into the room ...

Страница 11: ... apart then they will require replacement The bricks are held in place using the brackets welded to the firebox sides and the rear see fig 3 6 for brick details of brick layout Baffle The stainless steel baffle used in Clutha is made of thick gauge stainless steel it has a rear air intake chute which needs to be fitted properly into the slot on the back wall of the fire For flue cleaning this baff...

Страница 12: ...n the room incorrect flue system terrain pitch of the roof staggered roofs poor wood quality installation issues and or blocked flues Running the heater on a higher setting to increase the flue temperature especially when refuelling the heater Always make sure the room has an adequate air supply i e fresh air inlet make sure there are no extractor fans running and or heat transfer kits Different f...

Страница 13: ...n be the result of a poor Installation consult your local Masport representative to have this looked at in the first Instance Noise created by environmental influences can be resolved by changes to the System is flue terminations Performance issues Can be a result of installation issues poor wood quality where the heater is situated and environmental influences If you suspect your heater is not pe...

Страница 14: ...e defective in materials or workmanship Repairs will be carried out by an approved Logaire Heating Service Agent What is covered under this warranty Repair or replacement of parts Labour costs relating to the Wood Burner Reasonable transport or travel costs Consumers may have additional rights under the Consumer Guarantees Act 1993 New Zealand or the Australian Trade Practices Act 1974 including t...

Страница 15: ...quential losses or special damages of any kind including costs of collection and delivery other than repair or replacement of products or components under this warranty where any goods are acquired or used for the purposes of a business Performance issues due to site environmental conditions such as insufficient or excessive draught down draft Issues created due to such conditions are noise from t...

Страница 16: ...16 ...

Страница 17: ...feedback on the following questionnaire Question Please tick appropriate remark 1 General presentation of Product Excellent Good Ok Needs to Improve 2 Styling and Looks Excellent Good Ok Needs to Improve 3 Packaging Excellent Good Ok Needs to Improve 4 Is documentation easy to follow and informative Excellent Good Ok Needs to Improve 5 Fixtures Fittings Loose parts In order Items missing Needs to ...

Отзывы: