background image

  Please  read  carefully  all  the  dimensions  and  recommendations  provided  in  the  technical 

specification  section  of  this  manual.    The  dimensions  given  comply  with  the  required  safety 
standard AS/NZS 2918:2001.  

  For  safety,  operational  and  warranty  compliance,  altering  the  appliance  in  any  way,  should  not  be 

attempted, No modifications are permissible.  

  Please  ensure  that  only  components  approved  by  Masport  heating  New  Zealand  are  used  on  the 

installation, as substitutes may adversely affect performance and might  nullify compliance with the 
requirements of AS/NZS 2918 safety standards. 

  The  Clutha  burner  was  tested  using  a  Masport  flue  system,  it  is  recommended  that  it  is  installed 

using  a  Masport  flue  system  or  a  flue  system  that  has  been  tested  and  complies  with  AS/NZS 
2918:2001  Appendix  F.  All  Masport  burners  have  been  tested  using  a  Masport  double  flue  shield 
and this must be used with your installation. 

  Masport recommends that the flue system  must be serviced annually by a NZHHA trained service 

agent. 

4.1 Cautions 

  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical, 

sensory,  or  mental  capabilities  or  lack  of  experience  and  knowledge  unless  they  have  been 
given  supervision  or  instruction  concerning  the  use  of  the  appliance  by  a  person  responsible 
for their safety. 

  Do not leave children unattended near  the alighted fire and keep them well away from the fire 

when in use. Supervise young children to ensure that they do not play with the appliance. 

  Do  not  use  flammable  liquids  or  aerosols  to  start  or  rekindle  the  fire.    Also,  do  not  use  such 

flammable materials near this appliance when operating. 

  Always keep clothing, firewood, furnishing, and other combustible materials at a safe distance 

from the fire. 

  Do not touch any part of the fire other than the door handle and the air control when in use, as 

all other parts can be extremely hot.   

  A  Cracked/broken  door  glass  makes  operation  of  the  heater  unsafe.    Do  not  operate  the  fire 

with a cracked/broken door glass. 

  Do not attempt to clean or maintain the fire when in use or with hot embers in  the combustion 

chamber.    Ensure  that  embers  and  all  other  parts  of  the  fire  have  cooled  down  completely 
before starting ash removal or other maintenance.  

  Do  not  use  the  fire  if  there  is  a  malfunction,  a  suspicion  of  breakage,  or  unusual  noises.  

Contact your Masport dealer or customer service team at Glen Dimplex, New Zealand. 

  This appliance should always be operated & maintained as per instructions in this manual. 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

Failure to follow above warnings, cautionary measures 

and instruction given in this installation and operation 

manual will void the Masport Heating warranty of this 

product. 

Содержание CLUTHA

Страница 1: ...CE Manufactured in New Zealand by GLEN DIMPLEX NEW ZEALAND LIMITED P O Box 58473 Botany Manukau 2163 Ph 0800 666 2824 Fax 09 274 8472 Email sales glendimplex co nz Web www glendimplex co nz Part No 599586 V1 0 Glen Dimplex New Zealand Ltd reserves the right to change specifications the content of this manual or the design of its product without prior notice ...

Страница 2: ...N AND PAINT CURING 8 12 FUEL 8 12 1 WOOD MOISTURE 8 13 1 KINDLING INTERMEDIATE AND MAIN WOOD DETAIL 8 13 2 INITIAL LIGHT UP WITH KINDLING AND INTERMEDIATE LOAD 9 13 3 INTERMEDIATE LOAD 2 AND MAIN LOAD 9 13 4 CONTROLLING THE HEAT OUTPUT 9 13 5 REFUELING 9 14 ASH 10 15 OPTIMIZING THE BEST PERFORMANCE FROM YOUR HEATER 10 16 MAINTENANCE 10 11 17 REPLACEMENT PARTS 11 12 18 COMMON ISSUES AND PROBLEM SOL...

Страница 3: ...er hotter burn This type of construction makes the heat durable and can reduce service costs in the long run 2 Items supplied with the fire 1 x Masport ceiling plate 1 x St St Main Baffle 7 x Ceramic Bricks 1 x Installation and Operation Manual which includes The Technical and Clearance Specification Installation guidelines The Brick Baffle Layout 3 Handling and Transport The Clutha appliance has ...

Страница 4: ...on concerning the use of the appliance by a person responsible for their safety Do not leave children unattended near the alighted fire and keep them well away from the fire when in use Supervise young children to ensure that they do not play with the appliance Do not use flammable liquids or aerosols to start or rekindle the fire Also do not use such flammable materials near this appliance when o...

Страница 5: ...otector Front 300 mm H Flue Centre to Wall 384 mm D Floor Protector Side 117 mm F Flue Centre to Rear Wall 231 mm G Flue Centre to Side Wall 573 mm N Flue Centre to Floor Protector Front 656mm R Flue Centre to Wall Corner 543 mm WW Overall Width of Fire 495 mm K Floor Protector Depth 887 mm DD Overall Depth of Fire 524 mm HH Overall Height of Fire 894 mm Seismic Restraint In New Zealand it is a re...

Страница 6: ... Factor Single layer of continuous material 12mm 0 4 Single layer of continuous material 25mm 0 3 Two spaced layers of continuous material 12mm 12mm 0 2 Clearance factors for heat shield which is more than 45 degrees off the vertical Heat Shield Construction Minimum Air Gap Dimension Clearance Factor Single layer of continuous material 12mm 0 8 Single layer of continuous material 25mm 0 6 6 Ash He...

Страница 7: ... have an impact on how the flue system performs and may need additional components added to remedy these issues flue casings other than std height must be braced in accordance with relevant building codes Flue installations other than a std vertical type are not recommended however if an installation requires offsets guidelines are set out with AS NZS 2918 2001 and must be followed All flue pipe j...

Страница 8: ...servatives or impregnated with chemicals or glue Chipboard particleboard or laminated board Painted stained or oiled Driftwood or other salt impregnated wood Burning such materials is not good for the environment it can also damage the firebox and put you at the risk of voiding the warranty your Masport heater In NZ radiata pine or macrocarpa are the most commonly available softwood species suitab...

Страница 9: ...trolling the heat output Once the main load has a well established flame the air control can now be adjusted to a lower setting Do not turn the air control directly from the high setting to low adjust to approximately half setting wait for around 5 10mins the adjust to the lowest setting Adjusting directly from high to low will starve the fire of oxygen and result in a poor burn 13 5 Refueling Ref...

Страница 10: ...heater on the low setting permanently and after long periods on the low setting it is recommended the heater is run on high to burn away any unwanted built up of particulate within the heater and flue system NOTE For the heater to perform optimally it must have a good air supply in today s air tight homes this can an issue so it is advised that an adequate fresh air supply be fitted into the room ...

Страница 11: ... apart then they will require replacement The bricks are held in place using the brackets welded to the firebox sides and the rear see fig 3 6 for brick details of brick layout Baffle The stainless steel baffle used in Clutha is made of thick gauge stainless steel it has a rear air intake chute which needs to be fitted properly into the slot on the back wall of the fire For flue cleaning this baff...

Страница 12: ...n the room incorrect flue system terrain pitch of the roof staggered roofs poor wood quality installation issues and or blocked flues Running the heater on a higher setting to increase the flue temperature especially when refuelling the heater Always make sure the room has an adequate air supply i e fresh air inlet make sure there are no extractor fans running and or heat transfer kits Different f...

Страница 13: ...n be the result of a poor Installation consult your local Masport representative to have this looked at in the first Instance Noise created by environmental influences can be resolved by changes to the System is flue terminations Performance issues Can be a result of installation issues poor wood quality where the heater is situated and environmental influences If you suspect your heater is not pe...

Страница 14: ...e defective in materials or workmanship Repairs will be carried out by an approved Logaire Heating Service Agent What is covered under this warranty Repair or replacement of parts Labour costs relating to the Wood Burner Reasonable transport or travel costs Consumers may have additional rights under the Consumer Guarantees Act 1993 New Zealand or the Australian Trade Practices Act 1974 including t...

Страница 15: ...quential losses or special damages of any kind including costs of collection and delivery other than repair or replacement of products or components under this warranty where any goods are acquired or used for the purposes of a business Performance issues due to site environmental conditions such as insufficient or excessive draught down draft Issues created due to such conditions are noise from t...

Страница 16: ...16 ...

Страница 17: ...feedback on the following questionnaire Question Please tick appropriate remark 1 General presentation of Product Excellent Good Ok Needs to Improve 2 Styling and Looks Excellent Good Ok Needs to Improve 3 Packaging Excellent Good Ok Needs to Improve 4 Is documentation easy to follow and informative Excellent Good Ok Needs to Improve 5 Fixtures Fittings Loose parts In order Items missing Needs to ...

Отзывы: