Model: MC-1-M (2U)
Doc. Ref. no. : - m05/om/101
Issue no. 14
Page 13 of 103
User’s Manual
FIXED OUTPUTS
Pulse
1 PPS
Accuracy: ±500 ns Accuracy with GPS locked
Output: TTL into 250
Ω
Pulse Width: 200 (200 mS High & 800 mS Low signal)
Interface: BNC Female connector(Rear Panel)
Alarms
Three Isolated Dry Contacts to 230 VAC / 24VDC, 10 A:
1. GPS Lost
2. Watchdog
3. Power Fail
Interface: 8-Way Terminal Strip
Event/RTC ON
One Event per minute or per hour or RTC ON/OFF (Configurable)
Interface: 8-Way Terminal Strip (Rear Panel)
Event contact capacity: 350V DC, 120mA maximum
IRIGB-TTL -
DC Level Shift /
IEEE 1344/C37.118-2005
Format: IRIG-B(007) [IRIGB TTL] or IEEE 1344/C37.118-2005 (field
selectable)
Output: TTL into 50
Ω
Interface: BNC Female connector (Rear Panel)
Optional: up to 9.
Serial
COM1
Protocol: NMEA-0183 (RMC)
Port Settings: 9600-8-N-1
Output: RS232/RS485** (Factory Configurable)
Interface: DB9 Female Connectors (Rear Panel)
COM2
Protocol: NGTS/ T-Format
Port Settings: 4800/9600-7/8-N/E/O-1/2 (Configurable)
Output: RS232/RS485** (Factory Configurable)
Interface: DB9 Female Connectors (Rear Panel)
** RS232 is factory set