Temperature Indicator: 409-4IN
REF NO: m47/om/201
Issue NO: 04
Page 6 of 34
Fig 2. Front Panel for Panel Mount
Name of Part
Symbol
Function
UP key
Increment the Value of any Parameter
User presses during RUN mode to invoke segment testing mode*.
DOWN key
Decrement the Value of any Parameter.
Shows ambient value for T/C Input in RUN mode.
MENU key
Shows different SET Points, if pressed in RUN mode.
In Sub Menu it can be used to get to the next Parameter.
ENTER key
Use as an acknowledgement for Alarm Status.
It is also used to save the parameters to nonvolatile memory, when user
setting a proper data by Increment and decrement key for parameter
configuration.
PV
(Present
Value)
Display
PV
4 digital 4 inch RED Display
Display process value.
Display parameter name when user set parameter.
Display Parameter Value when in Edit mode.
Display error message when an error occurs.
Relay-1
Indication
RL1
ON when Relay-1 is energized & OFF otherwise.
Relay-2
Indication
RL2
ON when Relay-2 is energized & OFF otherwise.
TX Indication
Tx
ON when device is transmitting some Data (RS-485).
RX Indication
Rx
ON when device is receiving some Data (RS-485).
*
All digits segments display one after another. example. 1111, 2222, 3333 to 9.9.9.9.
After that unit will be in run mode.