6.16 Troubleshooting
The starter motor turns but the main engine does
not start
- Check that there is fuel in the tank (fill up)
- Check if the stop electromagnet is in the firing position
(consult Service Centre)
- Bleed the air bubbles from the fuel circuit (see par. 4.2)
The engine protection module is not activated
when the START button is pressed
- battery, and the electrical connections (reconnect).
- Check integrity of the battery (recharge or replace).
The generator switches off during the operating
period
- Check if a protection has been activated with the
relevant light coming on (remove the cause and retry
starting).
- Check if there is fuel in the tank (fill up).
There is a high grade of smoke at the engine
exhaust
- Check that the oil level in the sump does not exceed
the MAX index (restore level).
- Check that the generator is not in overload.
- Check calibration of the injectors (consult Service
Centre).
The engine runs irregularly
- Check the fuel filters (replace).
- Bleed the air bubbles from the fuel circuit (see par.
4.2).
The alternator voltage is too low
- Check the engine rpm:
1560 rpm without utilities connected at 50Hz
1860 rpm without utilities connected at 60Hz
- Excitation capacitors damaged (replace).
Starter battery flat
- Check the electrolyte level in the battery (restore the
level).
- Check functioning of the DC alternator.
- Check integrity of the battery.
The generator does not deliver power
- Check that the magnetothermal switch [Fig. 4, Ref. 2]
is in the “ON” position. If not, contact an authorised
Service Centre.
7 TRANSPORT AND HANDLING
For transport, all the generators are fixed to a pallet by
means of screws.
For handling on the boat use the engine lifting hooks
located under the top access door [Fig.3, Ref.2]. Hook
the generator carefully and lift it slowly without sudden
movements.
- Hooking the generator at points different from
that indicated may cause damage to the genera-
tor or be dangerous to the operators.
-
During lifting all personnel must keep a safe dis-
tance and the operators must wear protective hel-
mets.
8 SCRAPPING
At the end of its lifetime the generator must be taken to
official scrapyards.
Do not dispose of the generator
at household refuse disposal sites, as many of its
parts are polluting.
Содержание MARINE I.S. 21.5
Страница 3: ...IS 21 5 23 5 ma ma ma ma mas s s s se e e e e 3 2 1 2 3 5 6 7 8 9 4 10 SERIAL No...
Страница 5: ...IS 21 5 23 5 ma ma ma ma mas s s s se e e e e 5 12 9 8 7 6 10 4 5 1 2 3 4 5 11 1 3 2 2 4 5...
Страница 7: ...IS 21 5 23 5 ma ma ma ma mas s s s se e e e e 7 8 2 1 3 5 4 9 1 2 3 4 3 4...
Страница 8: ...IS 21 5 23 5 8 ma ma ma ma mas s s s se e e e e 10...