CAUTION

Do not start your pump dry (WITHOUT WATER).

• Fill water in pump in inverse pouring system. 

Close the pump outlet valve, release air vent screw on the 

pump head and open the inlet valve slowly until stable 

water flows from the air vent screw. Then fasten the 

screw. 

• Fill water in pump when liquid level is lower than pump. 

Before installing, pump and pipes must be filled with liquid 

fully and air vented. 

6.1. Check the rotary direction

Switch on the power supply and view the rotary direction 

by viewing the motor fan. From the motor end, pump shall 

run counter-clockwise.

6.2. Check before pump start-up 

• Check whether the pump is fixed securely.

• Check whether pump is filled with water fully and check 

whether liquid can flow freely.

• Check whether the voltage of power supply is stable.

• Check whether it turns correctly. 

• To make sure all pipe lines are connected tightly and can 

supply water normally. 

• The valves in the inlet pipe line are completely opened.  

• The outlet valve shall be opened slowly after the pump is 

started up.

•  Check  the  operation  pressure  if  pressure  meter  is 

installed. 

• Check all the controls for normal operation. If the pump is 

controlled by pressure switch, check and adjust the 

starting pressure and stopping pressure. Check the full 

load current to make sure it not surpasses the max 

allowed current. 

6.3. Frequency of pump starts

• Pump should not be started too frequently. It is suggest-

ed pump shall not be started more than 100 times per hour 

if the motor power is less or equal to 4 kW. When motor 

power is big than 4 kW, pump shall not be started more 

than 20 times in one hour.

•  Suggestion:  When  pump  running;  flow  should  be 

controlled at the range of 0.5-1.3 times of rated flow. 

• There should be no noise when pump running. If there is 

something wrong, stop pump and check it and repair. 

6.4. Frost protecting 

Pump can be used in the system with anti-frozen 

measures. If the pump is installed in easily frozen environ-

ment, suitable antifreeze shall be added to the transfer-

ring  liquid  to  prevent  pump  from  being  damaged.  If 

antifreeze is not used, pump shall not be used during 

periods of frost. Pump should be drained when stops 

using. 

6.5. The following should be checked regularly for pump.

• Pump working and operating pressure

• Possible leakage

• Possible motor overheat 

• Cleaning/replacement of all strainers (If strainers fit)

• The switch off time of motor overload

• Frequency of starts and stops 

• All control operation

If find faults, check system according to “Possible Failures, 

Causes, and Solutions” 

• Pump shall be cleaned and kept appropriately when it is 

not used for a long time.

•  Pump  shall  be  prevented  from  being  corrupted  and 

damaged in storage.

7. MAINTENANCE

CAUTION

Maintenance operations must be done by authorized 

personnel with protective clothing only.  The personnel 

must also beware of high temperatures and harmful 

and/or caustic liquids.  Make sure that the personnel read 

carefully the manual.

• The instructions in Safety Precautions must be executed 

during maintenance and repair

•  Continuous  monitoring  and  maintenance  will  increase 

the engine’s and pump’ s lives.

The instructions below should be applied.

7.1. The Checks During the Operation

• Pump must never be operated without water.

•  Pump  must  not  be  operated  for  a  long  time  with  the 

discharge valve closed (zero capacity). 

•  Bearing  temperature  must  never  exceed  80

°

C if the 

ambient temperature is 30

°

C

•  Precautions  must  be  taken  against  flare  up  when  the 

component temperatures are over 60

°

C. “Hot Surface” 

warnings must be placed over necessary areas. 

• All the auxiliary systems must be in use while the pump is 

operating.

• There is no need for excessive maintenance because of 

using mechanical seal. Water leakage from the mechani-

cal sealing indicates the fact that the sealing is worn out 

and therefore needs to be replaced.

• If the system consists of a substitute pump, keep it ready 

by operating it once a week. Check also the auxiliary 

systems of the substitute pump. 

HEXA Series

7

Содержание HEXA 1

Страница 1: ...Operating Manual July 2020 Revision No 01 HEXA SERIES Vertical Shaft Stainless Steel Pumps...

Страница 2: ...2...

Страница 3: ...n this operating manual and keep it for your future reference Warning sign against the electrical risks Sign for the operator s safety 1 IMPORTANT SAFETY PRECAUTIONS In order to minimize the accidents...

Страница 4: ...n a vertical rotating shaft which is designed for pressures up to 25 bar with a nominal speed of 2900 rpm and a maximum flow of 100 m3 h Efficiency values of the pump characteristic curves which are c...

Страница 5: ...at results from electrical connections must be removed To get more information about this subject you can referto domestic electrical instructions 3 4 Safety Measures for Maintenance and Installation...

Страница 6: ...edge ofthe pump motor The discharge pipe can then be drained independently of the pump and vice versa The pump should not be run with a closed discharge value as this will cause an increase in temper...

Страница 7: ...s Ifthe pump is installed in easilyfrozen environ ment suitable antifreeze shall be added to the transfer ring liquid to prevent pump from being damaged If antifreeze is not used pump shall not be use...

Страница 8: ...is also valid for the pumps which are sent to ourfactory orto our service points Maintain the safety ofthe personnel and the environment in everyfield procedure 7 3 Spare Parts The spare parts ofHEXAt...

Страница 9: ...it are defective a Change motor starter b Check control circuit Pumped water does not flow constantly a Suction pipe is too small b There is not sufficient water in pump water inlet c Liquid level is...

Страница 10: ...olt 4 Base Plate 67 Impeller Spacer Bushing 360 Nut for Stud 5 Casing Flange 69 Spacer Bearing Bushing 370 Fibered Nut 6 Coupling Guard 230 Wave Spring 390 Coupling Pin 8 Inlet Fluid Director 250 Mech...

Страница 11: ...mber HEXA 2 2 2 15 1 2 18 2 26 2 HEXA 4 4 2 4 16 1 4 19 4 22 2 HEXA 8 8 2 1 8 12 1 8 14 8 20 3 HEXA 12 12 2 12 10 1 12 12 12 18 3 HEXA 16 16 2 16 8 1 16 10 16 16 3 HEXA 20 20 1 20 8 1 20 10 20 17 3 HE...

Страница 12: ...LL STAGE NUMBERS 0 4 HEXA 20 FOR ALL STAGE NUMBERS 0 4 HEXA32 10 1 0 4 HEXA32 20 2 0 4 HEXA32 30 2 0 4 HEXA32 40 2 0 4 HEXA32 50 2 0 4 HEXA32 60 2 0 4 HEXA32 70 2 0 4 HEXA32 80 2 0 4 HEXA32 90 2 0 4 H...

Страница 13: ...NOTES...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...Office Center Service Ayd nl Mah Birlik OSB 1 Nolu Cd No 17 Tuzla 34953 stanbul Turkey Phone 90 216 456 47 00 Fax 09 216 455 14 24 Customer Service 90 850 888 8 627 e mail info masgrup com www masgrup...

Отзывы: