Masdaf HEXA 1 Скачать руководство пользователя страница 4

4

2. GENERAL 

2.1. Definition of Pump and Usage Areas 

The HEXA multistage in-line centrifugal pumps are 

designed for the following applications:

• Municipal water supply and pressure boosting

• Domestic water supply

• Boiler feed and condensate systems

• Cooling water systems

• Irrigation and dewatering

• Fire fighting

• Washing plants and washdown

• Water treatment plants

• Reserve osmosis systems

Thin,  non-explosive,  non-corossive  liquids,  containing 

no solid particles or fibres.

When pumping liquids with a density and/or viscosity 

higher than that of water, motors with correspondingly 

higer outputs must be used, if required. 

CAUTION

Please contact MAS DAF MAKINA SANAYI A.Ş. for 

liquids that have different chemical and physical 

specifications. 

Technical specifications of HEXA type pumps 

Suction Flange: 

DN 32-DN 100

Discharge Flange: 

DN 32-DN 100

Capacity: 

2-110 m

3

/h

Max. Hm:  

30 bar

Speed: 

2900-3600 RPM

Ambient Temperature 

Max +40°C

Liquid Temperature 

-15°C to +120°C

Min Inlet Pressure 

According to the NPSH Curve

Max Inlet Pressure 

See Chart on Page 11

Electrical Data 

See Motor Nameplate

Dimensions and Weights  See Catalogue 

Product Information as per Regulation No. 547/2012 (for 

Water Pumps with a Maximum Shaft Power of 150 kW) 

Implementing "Ecodesign" Directive 2009/125/EC   

Minimum Efficiency Index for MAS OMK-V Pump Series 

is shown on the pump label.

MEI values of MAS OMK-V Pump Series are shown on 

the pump characteristic curves.

Minimum Efficiency Index for MAS OMK-V Pump Series; 

Minimum 0.4. (MEI≥0,4)

‘Vertical multistage water pump’ (MS-V) means a 

glanded multi stage (i>1) rotodynamic water pump in 

which the impellers are assembled on a vertical 

rotating shaft, which is designed for pressures up to 25 

bar, with a nominal speed of 2900 rpm and a maximum 

flow of 100 m

3

/h.

Efficiency values of the pump characteristic curves, 

which are cut diameter, are expressed in %.

OMK-V Series water pumps, the pump efficiency can be 

achieved more than fix speed in case of variable speed 

control.

More information about the Ecodesign can be reached 

at www.europump.org. 

2.2. Performance Information

Actual performance of the pump can be obtained from 

the order page and/or from the test report. This 

information is given on the pump label.  The 

performance curves given in the catalog are valid for 

water whose density and viscosity are 

ρ

=1 kg/dm

3

 and   

ν

=1 cst. respectively. For those liquids whose densities 

and viscosities are different from those of water, please 

consult with 

MAS DAF MAKINA SANAYI A.Ş.

 since the 

performance curves vary with density and viscosity 

CAUTION

Do not operate the pump with a motor that has a different 

power except for the given catalog and label values. 

The pump is not to be operated at off-design point given in 

the order and supplied from the firm.

It is necessary to ensure that the instructions are obeyed 

for the safe running of the pump. 

2.3. Warranty Conditions

The entire products in our selling program are warranted by 

MAS DAF MAKINA SANAYİ A.Ş. 

The warranty conditions will only be valid when all the 

instructions about installation and start-up operations of 

the pump unit are taken into account.

2.4. Test 

All Pumps are dispatched for sale when all the performance 

and pressure tests are completed.  Proper assurance of 

material and fault-free operation of pumps whose 

performance tests are made is under the warrantyof 

MAS 

DAF MAKINA SANAYI A.Ş. 

2.5. Pressure Limit

Pressure at the discharge flange must not exceed 10 Bar. A 

special order is necessary for applications with higher 

pressures. 

Содержание HEXA 1

Страница 1: ...Operating Manual July 2020 Revision No 01 HEXA SERIES Vertical Shaft Stainless Steel Pumps...

Страница 2: ...2...

Страница 3: ...n this operating manual and keep it for your future reference Warning sign against the electrical risks Sign for the operator s safety 1 IMPORTANT SAFETY PRECAUTIONS In order to minimize the accidents...

Страница 4: ...n a vertical rotating shaft which is designed for pressures up to 25 bar with a nominal speed of 2900 rpm and a maximum flow of 100 m3 h Efficiency values of the pump characteristic curves which are c...

Страница 5: ...at results from electrical connections must be removed To get more information about this subject you can referto domestic electrical instructions 3 4 Safety Measures for Maintenance and Installation...

Страница 6: ...edge ofthe pump motor The discharge pipe can then be drained independently of the pump and vice versa The pump should not be run with a closed discharge value as this will cause an increase in temper...

Страница 7: ...s Ifthe pump is installed in easilyfrozen environ ment suitable antifreeze shall be added to the transfer ring liquid to prevent pump from being damaged If antifreeze is not used pump shall not be use...

Страница 8: ...is also valid for the pumps which are sent to ourfactory orto our service points Maintain the safety ofthe personnel and the environment in everyfield procedure 7 3 Spare Parts The spare parts ofHEXAt...

Страница 9: ...it are defective a Change motor starter b Check control circuit Pumped water does not flow constantly a Suction pipe is too small b There is not sufficient water in pump water inlet c Liquid level is...

Страница 10: ...olt 4 Base Plate 67 Impeller Spacer Bushing 360 Nut for Stud 5 Casing Flange 69 Spacer Bearing Bushing 370 Fibered Nut 6 Coupling Guard 230 Wave Spring 390 Coupling Pin 8 Inlet Fluid Director 250 Mech...

Страница 11: ...mber HEXA 2 2 2 15 1 2 18 2 26 2 HEXA 4 4 2 4 16 1 4 19 4 22 2 HEXA 8 8 2 1 8 12 1 8 14 8 20 3 HEXA 12 12 2 12 10 1 12 12 12 18 3 HEXA 16 16 2 16 8 1 16 10 16 16 3 HEXA 20 20 1 20 8 1 20 10 20 17 3 HE...

Страница 12: ...LL STAGE NUMBERS 0 4 HEXA 20 FOR ALL STAGE NUMBERS 0 4 HEXA32 10 1 0 4 HEXA32 20 2 0 4 HEXA32 30 2 0 4 HEXA32 40 2 0 4 HEXA32 50 2 0 4 HEXA32 60 2 0 4 HEXA32 70 2 0 4 HEXA32 80 2 0 4 HEXA32 90 2 0 4 H...

Страница 13: ...NOTES...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...Office Center Service Ayd nl Mah Birlik OSB 1 Nolu Cd No 17 Tuzla 34953 stanbul Turkey Phone 90 216 456 47 00 Fax 09 216 455 14 24 Customer Service 90 850 888 8 627 e mail info masgrup com www masgrup...

Отзывы: